期刊文献+

A non-invasive method for gastrointestinal parameter monitoring 被引量:15

A non-invasive method for gastrointestinal parameter monitoring
下载PDF
导出
摘要 AIM: To propose a new, non-invasive method for monitoring 24-h pressure, temperature and pH value in gastrointestinal tract.METHODS: The authors developed a miniature, multifunctional gastrointestinal monitoring system, which comprises a set of indigestible biotelemetry capsules and a data recorder.The capsule, after ingested by patients, could measure pressure, temperature and pH value in the gastrointestinal tract and transmit the data to the data recorder outside the body through a 434 MHz radio frequency data link. After the capsule passed out from the body, the data saved in the recorder were downloaded to a workstation via a special software for further analysis and comparison.RESULTS: Clinical experiments showed that the biotelemetry capsules could be swallowed by volunteers without any difficulties. The data recorder could receive the radio frequency signals transmitted by the biotelemetry in the body. The biotelemetry capsule could pass out from the body without difficulties. No discomfort was reported by any volunteer during the experiment. In vivo pressure and temperature data were acquired.CONCLUSION: A non-invasive method for monitoring 24-h gastrointestinal parameters was proposed and tested by the authors. The feasibility and functionality of this method are verified by laboratory tests and clinical experiments. AIM: To propose a new, non-invasive method for monitoring 24-h pressure, temperature and pH value in gastrointestinal tract. METHODS: The authors developed a miniature, multifunctional gastrointestinal monitoring system, which comprises a set of indigestible biotelemetry capsules and a data recorder. The capsule, after ingested by patients, could measure pressure, temperature and pH value in the gastrointestinal tract and transmit the data to the data recorder outside the body through a 434 MHz radio frequency data link. After the capsule passed out from the body, the data saved in the recorder were downloaded to a workstation via a special software for further analysis and comparison. RESULTS: Clinical experiments showed that the biotelemetry capsules could be swallowed by volunteers without any difficulties. The data recorder could receive the radio frequency signals transmitted by the biotelemetry in the body. The biotelemetry capsule could pass out from the body without difficulties. No discomfort was reported by any volunteer during the experiment. In vivo pressure and temperature data were acquired. CONCLUSION: A non-invasive method for monitoring 24-h gastrointestinal parameters was proposed and tested by the authors. The feasibility and functionality of this method are verified by laboratory tests and clinical experiments.
出处 《World Journal of Gastroenterology》 SCIE CAS CSCD 2005年第4期521-524,共4页 世界胃肠病学杂志(英文版)
基金 Supported by the National Natural Science Foundation of China, No. 30270382High Technology Research and Development Program of China, No. 2002AA404280
关键词 Gastrointestinal monitoring system PRESSURE TEMPERATURE Hydrogen Ion Concentration 非入侵方法 胃肠参数 压力温度 氢离子浓度 消化系统
  • 相关文献

参考文献30

  • 1Camilleri M. Disorders of gastrointestinal motility in neurologic diseases. Mayo Clin Proc 1990; 65:825-846. 被引量:1
  • 2Mathias JR, Sninsky CA, Millar HD, Clench MH, Davis RH.Development of an improved multi-pressure-sensor probe for recording muscle contraction in human intestine. Dig Dis Sci 1985; 30:119-123. 被引量:1
  • 3Zhou L, Ke MY. Textbook of gastrointestinal motility: Basic and clinical aspacts. Beijing Science Press 1999:369-385. 被引量:1
  • 4Powell AK, Ficia R, Bywater RA. Motility in the isolated mouse colon: migrating motor complexes, myoelectric complexes and pressure waves. Neurogastroenterol Motil 2003; 15:257-266. 被引量:1
  • 5Martinez-de-Juan JL,~Saiz J, Meseguer M, Ponce JL. Small bowel motility: relationship between smooth muscle contraction and electroenterogram signal. Med Eng Phys 2000; 22:189-199. 被引量:1
  • 6Van Schelven LJ, Nieuwenhuijs VB, Akkermans LM.Automated, quantitative analysis of interdigestive small intestinal myoelectric activity in rats. Neurogastroenterol Moti1 2002;14:15-23. 被引量:1
  • 7Meseguer Anastasio MF, Ponce Marco JL, Martinez de Juan JL, Silvestre J, Saiz J. Relation between the bowel electro myogram and the intestinal pressure wave: An experimental study in dogs. Rev Esp Enferm Dig, 2001; 93:779-793. 被引量:1
  • 8Tomomasa T, Morikawa A, Sandier RH, Mansy HA, Koneko H, Masahiko T, Hyman PE, Itoh Z. Gastrointestinal sounds and migrating motor complex in fasted humans. Am J Gastroenterol 1999; 94:374-381. 被引量:1
  • 9Liatsos C, Hadjileontiadis LJ, Mavrogiannis C, Patch D, Panas SM, Burroughs AK. Bowel sounds analysis: A novel noninvasive method for diagnosis of small-volume ascites. Dig Dis Sci 2003;48:1630-1636. 被引量:1
  • 10Mansy HA, Sandler RH. Detection and analysis of gastro intestinal sounds in normal and small bowel obstructed rats.Med Biol Eng Comput 2000; 38:42-48. 被引量:1