摘要 目的观察弹力型可活动外固定器械治疗近侧指间关节骨折脱位的疗效。方法1999年3月~2003年7月,我们应用弹力型可活动外固定器治疗近侧指间关节骨折脱位14例,新鲜骨折脱位6例,陈旧性骨折脱位8例。结果随访3~36个月,平均14.5个月。14例患者均达到完全骨性愈合,愈合时间平均为3个月。近侧指间关节伸直达0~20°,平均10°;屈曲达到65°~110°,平均87.5°。结论应用弹力型可活动外固定器械治疗近侧指间关节骨折脱位,是一种简便、可靠、效果较好的治疗方法。 Objective To observe the results of treating fr acture-dislocation of proximal int erphalangeal joint with elastic dynamic external fixator.Methods From March 1999to June 2003,we treated 14cases of frac-ture-dislocation of proximal interphalangeal joint with elastic dynam ic external fixator.They were 9men a nd 5women,6fresh ones and 8obsolete ones.Their ages ranged from 18to 48years old,with a mean age of 31.6.Results The follow-ups lasted from 3to 36months,with a mean period of 14.5months.Al l the 14cases healed completely.The average healing period was 3months.Extension angle of proximal interphalangeal joint was from 0to 20°,averaging10°.Flexion angle was from 65°to 110°,averaging 87.5°.Conclusion For fracture-dislocation of proxim al inter-phalangeal joint,the elastic dynam ic external fixator is a kind of conve nient,reliable and effective treatment device. [
出处 《中华创伤骨科杂志》 CAS CSCD 2005年第1期36-38,47,共4页 Chinese Journal of Orthopaedic Trauma
关键词 近侧指间关节 骨折固定术 骨折脱位 外固定器 Proximal interphalangeal joint Fracture fixation,external Fracture-dislocation External fixator
  • 相关文献

参考文献8

  • 1Kiefhaber TR, Stern PJ. Fracture dislocations of the proximal interphalangeal joint. J Hand Surg(Am), 1998, 23: 368-380. 被引量:1
  • 2傅中国,姜保国,张殿英,王天兵,李剑,Nabees.手掌指骨折AO微型钛金属板内固定临床应用[J].中华创伤骨科杂志,2003,5(2):103-105. 被引量:23
  • 3Morgan JP, Gordon DA, Klug MS, Perry PE, Barre PS. Dynamic digital traction for unstable comminuted intraarticular fracture-dislocations of the proximal interphalangeal joint. J Hand Surg(Am), 1995, 20: 565-573. 被引量:1
  • 4Newington DP, Davis TR, Barton NJ. The treatment of dorsal fracture-dislocation of the proximal interphalangeal joint by closed reduction and Kirschner wire fixation: a 16-year follow up. J Hand Surg(Br), 2001, 26: 537-540. 被引量:1
  • 5Watt BC, Edwards RB 3rd, Markel MD, McCabe R, Wilson DG. Arthrodesis of the equine proximal interphalangeal joint: a biomechanical comparison of three 4.5-mm and two 5.5-mm cortical screws. Vet Surg, 2001, 30: 287-294. 被引量:1
  • 6Tekkis PP, Kessaris N, Gavalas M, Mani GV. The role of mini-fragment screw fixation in volar dislocations of the proximal interphalangeal joint. Arch Orthop Trauma Surg, 2001, 121: 121-122. 被引量:1
  • 7Syed AA, Agarwal M, Boome R. Dynamic external fixator for pilon fractures of the proximal interphalangeal joints: a simple fixator for a complex fracture. J Hand Surg(Br), 2003, 28: 137-141. 被引量:1
  • 8Duteille F, Pasquier P, Lim A, Dautel G. Treatment of complex interphalangeal joint fractures with dynamic external traction: a series of 20 cases. Plast Reconstr Surg, 2003, 111: 1623-1629. 被引量:1