期刊文献+

高温高压蒸汽管线的强度校核及异径管的三维有限元应力分析 被引量:8

Strength Check of a Steam Line Under High Temperature and High Pressure and Stress Analysis of an Eccentric Reducer
下载PDF
导出
摘要 分别用等值刚度法FAOP计算程序及三维有限元法SAP5p计算程序,对管线进行了应力计算。其结果表明,管线静强度足够。还用SAP5p对环缝出现长裂纹的异径管进行了细部应力分析,给出了裂纹所在截面的轴向应力数值。 Stress calculations of a Steam line under nigh temperature and pressure have been finished employing FAOP program of equivalent stiffness method and SAP5p program of finite element method. That results show that static strength of the line is satisfied. Furthermore, detail stress analysis for an eccentric reducer with circumferential welds among which there is a longer crack is completed by resorting to isoparametric element with 8-21 nodes of SAP5p program. The value of axial stress of the section in which the crack located is given.
出处 《石油化工设备》 CAS 北大核心 1993年第3期41-45,共5页 Petro-Chemical Equipment
  • 相关文献

参考文献2

二级参考文献3

  • 1成建国,王牧,李书臣.高温高压换热器管板泄漏分析中疲劳载荷谱的编制[J]压力容器,1986(02). 被引量:1
  • 2阎楚良,王公权.雨流计数法及其统计处理程序研究[J]农业机械学报,1982(04). 被引量:1
  • 3(日)埰见弘等著,陆振海.可靠性分析用概率纸的使用方法[M]机械工业出版社,1988. 被引量:1

共引文献3

同被引文献60

引证文献8

二级引证文献22

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部