摘要
分析 30 0MW机组发电机定子冷却水水质劣化的原因 ,提出改善水质的技术对策与措施 ,总结技术改进实施效果与经验 。
The reason for the impurity in the stator cooling water of 300 MW unit is analyzed. The technical countermeasure of water quality improvement is put forward. The result and experience of the technical improvement are summarized. This experience can be used as reference for the water quality control of the stator cooling water in generators of the same kind and for chemical monitoring work.
出处
《工业水处理》
CAS
CSCD
2001年第11期33-35,共3页
Industrial Water Treatment
关键词
厦门嵩屿
电厂
发电机定冷水
水处理
技术改进
generator stator cooling water
water treatment
technical improvement