摘要
分析了 2 0 0kt/a聚丙烯装置G - 2 0 1丙烯泵振动的原因 ,介绍通过采用干气密封技术、管路改造和提高安装精度等技改措施 ,解决了该泵振动的难题 。
Analyze reason of the vibration of the propylene pump G201 of the 200kt/a polypropylene unit, and solve the vibration problem by using dry gas sealing, retrofitting pipeline route and improving installation accuracy etc. so as to postpone continuous operation time of the pump.
出处
《化工设计》
CAS
2004年第4期40-41,48,共3页
Chemical Engineering Design