期刊文献+

电力系统稳定器配置、构成、参数计算及投运试验 被引量:25

<title>sposition, configuration, parameter calculation and commissioning of PSS
下载PDF
导出
摘要 介绍电力系统稳定器(PSS)的配置要求及各种输入信号的PSS的特点及适用范围,交流励磁机磁机系统适合采用以△Pe为输入信号的PSS,水轮发电机适合采用△Pe+△Pf为输入信号的PSS。论述PSS相位补偿及增益选取的计算方法,PSS相位补偿要求考虑各种运行方式,使PSS魯棒性较好,并介绍PSS的现场试验方法等。 <abstract>is paper introduces the requirements of PSS disposition, and the characteristics and suitable scope of various input signals. PSS with input signal Pe used in alternating exciter system and PSS adopting input signal △Pe+△Pf used in hydropower generator are also described. The calculation method of PSS phase compensation and gain selection is discussed. Various operation modes should be considered for PSS phase compensation, which makes robot of PSS better. The method of field test of PSS is introduced.
出处 《中国电力》 CSCD 北大核心 2004年第10期8-13,共6页 Electric Power
关键词 PSS 电力系统稳定器 交流励磁机 水轮发电机 相位补偿 投运 参数计算 输入信号 增益 配置 <keyword>citation system PSS phase compensation gain