期刊文献+

颈椎侧块钢板治疗下颈椎骨折脱位 被引量:1

Treatment of cervical spine fracture and dislocation with lateral cervical mass plate
原文传递
导出
摘要 目的 观察颈椎侧块钢板治疗颈椎骨折、脱位的疗效。方法 对采用颈椎侧块钢板治疗 5 4例颈椎骨折、脱位患者的临床资料进行回顾性分析。结果 术后患者均无神经、血管并发症。通过 4~ 36个月的随访 ,颈椎侧块钢板对颈椎固定牢靠 ,无螺钉松脱及钢板断裂现象 ,同时对颈椎滑脱有良好的复位作用。全部达到骨性愈合 ,脊髓功能除 5例按Frankle分级为A级者术后 3个月无明显改善外 ,其余均有不同程度改善。结论 颈椎侧块钢板适用于需要后路减压的颈椎骨折、脱位 ,对其有良好的复位和固定作用 ,有利于脊髓功能的恢复 ;本方法还具有短节段固定 ,术后仅需轻便外固定 ,可早期活动等优点。该手术有一定风险 ,因此要求术者技术熟练 ,操作规范。 Objective To observe the curative effect of cervical spine fracture or dislocation following the placement of lateral cervical mass plate.Methods Clinical data of 54 cases of cervical spine fracture or dislocation treated with lateral cervical spine mass plate were retrospectively analyzed.Results No complications of nerve endings and vessels were found.During 4-36 months followed-up in 54 cases,the cervical spine was fixed very firmly and there was no loosening of the plates and screws.This internal fixer was very suitable for reposition of cervical spine dislocation.All cases had bone union.The spinal cord function of all patients (except 5 cases of Frankle A) was improved to various degrees.Conclusions The stability can be obtained with the screws-plating fixation to lateral cervical mass.It is a good technique for restoring stability of cervical vertebrae and spinal cord function.It has advantages of short segment fixation,light external post-operative fixation and early exercise.It has certain risk so the skillful performance is the key to success of operation.
出处 《中国综合临床》 北大核心 2004年第10期931-933,共3页 Clinical Medicine of China
关键词 颈椎骨折 内固定器 脱位 Cervical spine fracture Internal fixation Dislocation
  • 相关文献

参考文献7

  • 1Roy-Camille R, Roy-Camille M, Demeulenaere C. Osteosynthesis of dorsal.lumbar, and lumbosacral spine with metallic plates screwed into vertebral pedicles and articular apophyses [J]. Presse Med,1970,78 (32): 1447-1448. 被引量:1
  • 2Gill K, Paschal S, Corin J, et al. Posterior plating of the cervical spine. A biomechanical comparison of different posterior fusion techniques[J]. Spine, 1988,13 (7) :813-816. 被引量:1
  • 3Anderson PA, Henley MB, Grady MS, et al. Posterior cervical arthrodesis with AO reconstruction plates and bone graft[J]. Spine, 1991 ,16(3 Suppl) :S 72-79. 被引量:1
  • 4Pache T. Results of 14 cervical luxations or subluxations stabilized with posterior Louis' plates. In: Louis R, Weidner A, eds. Cervical spine [M]. 2nd ed. Berlin: Springer-Verlag, 1988.98-103. 被引量:1
  • 5Heller JG. Carlson GD, Abitbol JJ, et al. Anatomic comparison of the Roy-Camille and Magerl techniques for screw placement in the lower cervical spine[J]. Spine, 1991,16 ( 10 Suppl): S 552-557. 被引量:1
  • 6刘忠军,党耕町,刘晓光,马庆军.AO带锁型钢板螺钉在颈椎外伤治疗中的应用[J].中华骨科杂志,1997,17(1):33-36. 被引量:43
  • 7魏新荣,张光铂.SCEP监测在脊柱外科手术中的应用[J].中国脊柱脊髓杂志,1993,3(3):110-113. 被引量:8

共引文献49

同被引文献11

  • 1刘智,孙天胜,李京生,刘树清,任继新.早期手术治疗急性颈脊髓损伤[J].中华创伤骨科杂志,2004,6(11):1206-1208. 被引量:14
  • 2陆建忠,唐守英,王贵青,贾粤青.一期前后联合手术减压固定治疗严重下颈椎骨折脱位[J].中国矫形外科杂志,2005,13(12):955-956. 被引量:18
  • 3张宏其,向伟能,陈静,罗继,鲁世金,陈凌强,胡建中,王锡阳.Ⅰ期前后路联合手术治疗严重下颈椎骨折脱位[J].中国矫形外科杂志,2007,15(10):727-730. 被引量:23
  • 4Mahadewa T,Mizuno J,Inoue T,et al.Traumatic C6-7 subluxation associated with C-7 fracture treated with a pedicle screw system under navigation guidance-case report[J].Neurol Med Chir(Tokyo),2005,45(2):87-91. 被引量:1
  • 5Abumi K,Kaneda K,Shono Y,et al.One-stage posterior decompression and reconstruction of the cervical spine by using pedicle screwfixation systems[J].J Neurosurg,1999,90(1 Suppl):19-26. 被引量:1
  • 6Abumi K,Shono Y,Ito M,et al.Complications of pedicle screw fixation in reconstructive surgery of the cervical spine[J].Spline(Phila Pa 1976),2000,25(8):962-969. 被引量:1
  • 7Orndorff DG,Samartzis D,Whitehill R,et al.Traumatic fracture-dislocation of C5 on C6 through a previously solid multilevel anterior cervical discectomy and fusion:a cage report and review of the literature[J].Spine J,2006,6(1):55-60. 被引量:1
  • 8Mizuno J,Nakgawa H,Watabe T.Combined anterior and posterior instrumentation in severe fracture-dislocation of the lower cervical spine with help of navigation:a case report[J].J Clin Neurosci,2001,8(5):446-450. 被引量:1
  • 9Barnes AH,Eguizabal JA,Acosta FL Jr,et al.Biomechanical pullout strength and stability of the cervical artificial pedicle screw[J].Spine (Phila Pa 1976),2009,34(1):E16-20. 被引量:1
  • 10侯黎升,阮狄克,何勍,徐云科,叶晓健,贾连顺,徐成,赵书臣,张燕群,张荣峰,李威.改良Abumi法行下颈椎椎弓根钉植入[J].颈腰痛杂志,2008,29(4):291-295. 被引量:4

引证文献1

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部