冠状动脉阻抗系统的建立及其稳定性 被引量:1

Establishment and Reproducibility of a Coronary Arterial Resistance Evaluating System
下载PDF
导出
摘要 目的 利用计算机和图像、信号采集设备建立冠状动脉阻抗系统 ,并研究冠状动脉阻抗参数的稳定性。方法 与心电信号同步通过腔内超声导管、多普勒导丝和压力导丝 ,获取随心动周期变化的冠状动脉腔内超声图像、流速和压力信号 ;通过自制软件得到随心动周期变化的腔内面积曲线、平均流速曲线、压力曲线和流量 /压力曲线 ;按机电类比方法通过傅立叶变换得到冠脉阻抗参数。采集不同情况下 1 0头小型猪以及 2 1例病人左前降支的基础状态和最大充血状态重复性测量信号分别为 80对。结果 相关分析发现重复性冠脉阻抗参数间有很好的相关性 (P <0 .0 1 ) ;基础状态和充血状态的平均冠脉阻抗和一次谐波冠脉阻抗的决定系数 (r2 )均大于0 .97(P <0 .0 0 1 )。结论 本实验成功建立反映冠脉脉动流阻力的冠脉阻抗系统 。 Purpose: The purpose of the present study was to establish the resistance evaluating system of coronary artery based on self-made software and to investigate the reproducibility of coronary resistance (CR) parameters. Methods: Intra-vascular ultrasound (IVUS) images, intracoronary Doppler and pressure signals in the left anterior descending artery (LAD) of 10 pigs and 21 patients were acquired using intracoronary ultrasound imaging catheter, Doppler flow wire and pressure wire separately. The images and signals were respecively sampled into a computer using the image and signal acquistition cards and the corresponding software. A modified active contour model was used to estimate the lumen area of the coronary artery from IVUS images, and a method integrating morphology and dynamic programming were applied to extract the variation of velocity from the Doppler spectrum. With the electrocardiograph as the synchronization, variation of blood volume in a cardiac cycle was calculated as velocity minus area. The curve of volume/ pressure in a cardiac cycle was derived from the curve of volume and pressure. Hereby, the CR parameters for the coronary artery in frequency domain were computed as pressure divided by volume using the Fourier series of blood volume and pressure. A total of 80 pairs of repeated-computer CR parameters were obtained separately in baseline and hyperemia conditions. Results: A highly linear correlation existed between two reproducible CR parameters (P < 0.01). Coefficient of determination of average CR and the first-harmonic CR in baseline and hyperemia conditions were greater than 0.97 (P < 0.001). Conclusions: The curve of volume/pressure in a cardiac cycle and resistance parameters for coronary circulation were established successfully through the software of PC system.
出处 《复旦学报(医学版)》 EI CAS CSCD 北大核心 2004年第4期331-335,共5页 Fudan University Journal of Medical Sciences
基金 上海市医学重点发展基金 (2 0 0 0IZD0 0 2 ) 复旦大学Med-X重点培育基金资助项目
关键词 冠状动脉 阻抗系统 建立 稳定性 多普勒 压力 血管内超声 Cardiology Computer software Doppler effect Dynamic programming Electrocardiography Medical imaging Ultrasonics
  • 相关文献

参考文献11

  • 1Weissman NJ,Palacios IF,Weyman AE.Dynamic expansion of the coronary arteries:implication for intravascular ultrasound measurements.Am Heart J,1995,130:46 被引量:1
  • 2Geschwind HJ,Kern MJ.Guidebook to endovascular coronary diagnostic techniques,Published by Futura publishing company.Inc,1997:348 被引量:1
  • 3Meuwissen M,Siebes M,Chamuleau SA,et al.Hyperemic stenosis resistance index for evaluation of functional coronary lesion severity.Circulation,2002,106(4):441 被引量:1
  • 4Meuwissen M,Chamuleau SA,Siebes M,et al.Role of variability in microvascular resistance on fractional flow reserve and coronary blood flow evlocity reserve in intermediate coronary lesions.Circulation,2001,103(2):184 被引量:1
  • 5McGinn AL,White CW,Wilson RF.Interstudy variability of coronary flow reserve:influence of heart rate,arterial pressure,and ventricular preload.Circulation,1990,81:1319 被引量:1
  • 6Cleary RM,Moore NB,DeBoe SF,et al.Sensitivity and reproducibility of the instantaneous hyperemic flow versus pressure slope index compared to coronary flow reserve for the assessment of stenosis severity.Am Heart J,1993,126(1):57 被引量:1
  • 7Klingensmith JD,Shekhar R,Vince DG.Evaluation of three-dimensional segmentation algorithms for the identification of luminal and medial-adventitial borders in intravascular ultrasound images.IEEE Trans Med Imag,2000,19:996 被引量:1
  • 8Caracciolo EA,Wolford TL,Underwood RD,et al.Influence of intimal thickening on coronary blood flow responses in orthotopic heart transplant recipients.A combined intravascular Doppler and ultrasound imaging study.Circulation,1995,92(9 Suppl):Ⅱ182 被引量:1
  • 9张良惠,钱菊英,张庆勇,蔡乃绳,罗忠池,汪源源,王威琪,葛均波.经导管急性微血管栓塞对冠状动脉血流和冠状动脉血流储备的影响[J].中国介入心脏病学杂志,2003,11(3):117-119. 被引量:5
  • 10柳兆荣 李惜惜.血液动力学原理和方法[M].上海:复旦大学出版社,1999.210. 被引量:1

二级参考文献6

  • 1Geschwind H J, Kern MJ. Guidebook to endovascular coronary diagnostic techniques. Armonk, New York: Futura publishing company, 1997. 348-349. 被引量:1
  • 2Hofi M, Inoue M, Kitakaze M, et al. Role of adenosine in hyperemic response of coronary blood flow in microembolization. Am J Physiol,1986,250(3 Pt 2) :H509-518. 被引量:1
  • 3Skyschally A, Schulz R, Erbel R, et al. Reduced coronary and inotropic reserves with coronary microembolization. Am J Physiol Heart Circ Physiol, 2002,282:H611-614. 被引量:1
  • 4Dorge H, Neumann T, Behrends M, et al. Perfusion-contraction mismatch with coronary microvascular obstruction: role of inflammation.Am J Physiol Heart Circ Physiol, 2000,279:H2587-2592. 被引量:1
  • 5Hori M, Tamai J, Kitakaze M, et al. Adenosine-induced hyperemia attenuates myocardial ischemia in coronary microcmbolization in dogs.Am J Physiol, 1989,257(1 Pt 2) :H1244-251. 被引量:1
  • 6de Bruyne B, Bartunek J, Sys SU, et al. Simultaneous coronary pressure and flow velocity measurements in humans. Feasibility,reproducibility, and hemodynamic dependence of coronary flow velocity reserve, hyperemic flow versus pressure slope index, and fractional flow reserve. Circulation. 1996, 94(8) : 1842-1849. 被引量:1

共引文献4

同被引文献7

引证文献1

二级引证文献3

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部