期刊文献+

Three-dimensional dynamic contrast-enhanced MR angiography for evaluating recipient vessels in orthotopic liver transplantation 被引量:8

Three-dimensional dynamic contrast-enhanced MR angiography for evaluating recipient vessels in orthotopic liver transplantation
下载PDF
导出
摘要 BACKGROUND: With the improvement of MR technology, three-dimensional dynamic contrast-enhanced MR angiography (3D-DCE-MRA) may be the optimal vascular imaging method for preoperative evaluation of liver transplantation candidates. This study was undertaken to determine the value of 3D-DCE-MRA in the assessment of recipient vessels in orthotopic liver transplantation (OLT). METHODS: The surgical and pathological records were taken as the 'gold standards'. Eighteen cases of OLT were retrospectively analyzed to assess the image quality of MRA, including the signal-to-noise ratio (SNR) in arteries and veins, depiction of vascular variation and vessel disease, and the accuracy of vascular diameter measurement. RESULTS: 3D-DCE-MRA of 34 cases was carried out before OLT. The rates (excellent and good) showing hepatic arteries and portal vein for 3D-DCE-MRA were 94.1% (32/34) and 88.2% (30/34), respectively. The SNRs of the celiac axis and portal vein measurements from 3D-DCE-MRA were 20.58 +/- 3.74 and 13.43 +/- 4.12, and the mean diameters were 3.4 +/- 0.3 rum and 13.1 +/- 3.2 mm, respectively. There were 5 cases of vessel variation according to the Michel's classification. Of the 34 patients, 18 were compared radiologically and pathologically. The accuracy of depiction of the hepatic artery and portal vein with 3D-DCE-MRA was 100% for both; 3D-DCE-MRA precisely assessed 4 cases of more than moderate stenosis in hepatic arteries, 2 cases of small-caliber hepatic artery, 3 cases of venous stenosis at the second porta hepatis, 6 cases of collateral vasculature, I case of portal vein thrombosis and I case of portal vein aneurysm; all were confirmed pathologically. CONCLUSION: 3D-DCE-MRA may be the first choice for recipient vascular assessment before OLT. BACKGROUND: With the improvement of MR technology, three-dimensional dynamic contrast-enhanced MR angiography (3D-DCE-MRA) may be the optimal vascular imaging method for preoperative evaluation of liver transplantation candidates. This study was undertaken to determine the value of 3D-DCE-MRA in the assessment of recipient vessels in orthotopic liver transplantation (OLT). METHODS: The surgical and pathological records were taken as the 'gold standards'. Eighteen cases of OLT were retrospectively analyzed to assess the image quality of MRA, including the signal-to-noise ratio (SNR) in arteries and veins, depiction of vascular variation and vessel disease, and the accuracy of vascular diameter measurement. RESULTS: 3D-DCE-MRA of 34 cases was carried out before OLT. The rates (excellent and good) showing hepatic arteries and portal vein for 3D-DCE-MRA were 94.1% (32/34) and 88.2% (30/34), respectively. The SNRs of the celiac axis and portal vein measurements from 3D-DCE-MRA were 20.58 +/- 3.74 and 13.43 +/- 4.12, and the mean diameters were 3.4 +/- 0.3 rum and 13.1 +/- 3.2 mm, respectively. There were 5 cases of vessel variation according to the Michel's classification. Of the 34 patients, 18 were compared radiologically and pathologically. The accuracy of depiction of the hepatic artery and portal vein with 3D-DCE-MRA was 100% for both; 3D-DCE-MRA precisely assessed 4 cases of more than moderate stenosis in hepatic arteries, 2 cases of small-caliber hepatic artery, 3 cases of venous stenosis at the second porta hepatis, 6 cases of collateral vasculature, I case of portal vein thrombosis and I case of portal vein aneurysm; all were confirmed pathologically. CONCLUSION: 3D-DCE-MRA may be the first choice for recipient vascular assessment before OLT.
机构地区 Dalian Med Univ
出处 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2008年第5期476-480,共5页 国际肝胆胰疾病杂志(英文版)
基金 a grant from Dalian Scientific Foundation,China(No.2004B3SF140).
关键词 magnetic resonance ANGIOGRAPHY liver transplantation magnetic resonance angiography liver transplantation
  • 相关文献

参考文献3

二级参考文献66

  • 1Pieters PC, Miller PC, Demeo JH. Evaluation of the portal venous system: complementary roles of invasive and noninvasive imaging strategies. Radiographics,1997,17:879-895. 被引量:1
  • 2Bradbury MS, Kavanagh PV, Chen MY, et al. Noninvasive assessment of portomesenteric venous thrombosis: current concepts and imaging strategies. J Comput Assist Tomogr, 2002, 26: 392-404. 被引量:1
  • 3Sakamoto I, Hayashi K, Matsunaga N, et al. Aortic dissection caused by angiographic procedures. Radiology,1994,191:467-467. 被引量:1
  • 4Finn JP, Kane RA, Edelman RR, et al. Imaging of the portal venous system in patients with cirrhosis: MR angiography vs duplex Doppler sonography. Am J Roentgenol,1993,161:989-994. 被引量:1
  • 5Hughes LA, Hartnell GG, Fin JP, et al. Time-of-flight MR angiography of the portal venous system: value compared with other imaging procedures. Am J Roentgenol, 1996, 166:375-378. 被引量:1
  • 6Rodgers PM, Ward J, Baudouin CJ, et al. Dynamic contrast-enhanced MR imaging of the portal venous system: comparison with x-ray angiography. Radiology,1994,91:741-745. 被引量:1
  • 7Laissy JP, Trillaud H, Douek P. MR angiography: noninvasive vascular imaging of the abdomen. Abdom Imaging, 2002, 27:488-506. 被引量:1
  • 8Saddik D, Frazer C, Robins P, et al. Gadolinium-enhanced three-dimensional MR portal venography. Am J Roentgenol, 1999, 172:413-417. 被引量:1
  • 9Okumura A, Watanabe Y, Dohke M, et al. Contrast-enhanced three-dimensional MR portography. Radiographics,1999, 19:973-987. 被引量:1
  • 10Bach AM, Hann LE, Brown KT, et al. Portal vein evaluation with US: comparion to angiography combined with CT arterial portography. Radiology, 1996, 201: 149-154. 被引量:1

共引文献8

同被引文献33

引证文献8

二级引证文献25

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部