期刊文献+

多延时互耦合半导体激光器的实时混沌同步特性 被引量:3

Properties of Isochronal Chaos Synchronization of Semiconductor Lasers with Multiple Mutual Time-delayed Couplings
下载PDF
导出
摘要 针对双延时和三延时互耦合半导体激光器系统,研究了互耦合延时和互耦合强度对实时混沌同步质量的影响,提出了双延时互耦合系统中可将其中一个互耦合延时看作反馈延时的思想,揭示了多延时互耦合半导体激光器系统实时混沌同步条件和规律.研究结果表明,多延时互耦合系统中,某两条双向链路的互耦合延时比值为2,是实现高品质实时混沌同步的基本条件;增大互耦合强度,可以改善实时混沌同步品质,且在较低的等效耦合强度条件下,双延时互耦合系统较三延时互耦合系统更易于实现良好的实时混沌同步. Based on systems of semiconductor lasers with two mutual time-delayed couplings and three mutual time-delayed couplings,the influence of coupling delays and coupling strength to isochronal chaos synchronization was numerically studied.A thought that one coupling delay could be seen as feedback delays was presented in the system with two mutual time-delayed couplings.The condition and law for isochronal chaos synchronization was revealed in the system of semiconductor lasers with multiple mutual time-delayed couplings.The results show that the ratio 2 of two coupling delays is a basic condition to achieve isochronal chaos synchronization with high quality.Increasing coupling strength can improve the quality of isochronal chaos synchronization,and when the coupling strength is lower,the system with two mutual time-delayed couplings is much easier to achieve good isochronal chaos synchronization than system with three mutual time-delayed couplings.
出处 《光子学报》 EI CAS CSCD 北大核心 2012年第9期1023-1027,共5页 Acta Photonica Sinica
基金 国家自然科学基金(No.60976039) 四川省基础研究项目(No.2011JY0030)资助
关键词 半导体激光器 实时混沌同步 延时互耦合 耦合延时比 Semiconductor laser Isochronal chaos synchronization Mutual time-delayed couplings Ratio of coupling delays
  • 相关文献

参考文献18

二级参考文献114

共引文献38

同被引文献27

  • 1陈东,张伯昆,胡燮,刘文清,张玉钧.基于差频中红外激光的痕量气体高分辨光谱检测研究[J].光子学报,2012,41(6):678-683. 被引量:14
  • 2王娜,王安帮,张明江,徐航,杨玲珍,王云才.利用可调谐的混沌Fabry-Perot激光器实现波分复用无源光网络的断点检测[J].光子学报,2012,41(11):1279-1285. 被引量:6
  • 3陈刚,张方正,潘时龙.一种新型分布反馈半导体激光器的多信号直调性能研究[J].光子学报,2013,42(9):1-7. 被引量:3
  • 4KOSKINEN V, FONSEN J, KAUPPINEN J, et al. Extremely sensitive trace gas analysis with modern photoacoustic spectroscopy [J]. Vibrational Spectroscopy,2006, 42(2): 239-242. 被引量:1
  • 5ZENINARI V, GROSSEL A, JOLY L, et al. Photoacoustic spectroscopy for trace gas detection with cryogenic and room temperature continuous-wave quantum cascade lasers [J]. Central European Journal of Physics, 2010, 8(2) : 194-201. 被引量:1
  • 6ZHANG Yu, GAO Wen-zhu, SONG Zhen-yu, et al. Design of a novel gas sensor structure based on mid-infrared absorption spectrum[J]. Sensors and Actuators B : Chemical, 2010, 147(1): 5-9. 被引量:1
  • 7ZHENG Chuan-tao, YE Wei-lin, LI Guo-lin, et al. Performance enhancement of a mid-infrared CH4 detection sensor by optimizing an asymmetric ellipsoid gas-cell and reducing voltage-fluctuation: Theory, design and experiment[J]. Sensors and Actuators B, Chemical, 2011, 160(1): 389-398. 被引量:1
  • 8YE Wei-lin, ZHENG Chuan-tao, YU Xin, et al. Design and performances of a mid-infrared CH4 detection device with novel three-channel-based LS-FTF self-adaptive denoising structure[J]. Sensors and Actuators B, Chemical, 2011, 155(1) : 37-45. 被引量:1
  • 9MARTIN P A. Near-infrared diode laser spectroscopy in chemical process and environmental air monitoring [ J ]. Chemical Society Reviezo, 2002, 31(4) : 201-210. 被引量:1
  • 10WILLER U, SARAJI M, KHORSANDI A. Near-and mid- infrared laser monitoring of industrial processes, environment and security applications [J]. Optics and Lasers in Engineering, 2006, 44(7) : 699-710. 被引量:1

引证文献3

二级引证文献27

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部