期刊文献+

一种新型反应堆安全级DCS模拟量隔离技术 被引量:2

A New Type of Analog Signal Isolation Technology Applied to Nuclear Reactor Safety Level DCS
下载PDF
导出
摘要 为了保证安全级分布式控制系统(DCS)对现场模拟信号采集的安全性和可靠性,需要在DCS模拟量采集的前端安装相应的隔离分配装置.采用电容充放电进行模拟量隔离,用定时器和逻辑门电路产生开关的控制时序信号.通过调整电容充放电时间,控制采样和保持的时序,配合光电开关实现对模拟信号的隔离,隔离后的模拟量信号经过电压电流转换后输出.经过对时序的控制器件参数的选择和匹配,在不校准的条件下,装置精度可达到0.05%,温度漂移低于2×10-5/℃,电气隔离度达到1500 Vp@1 min<5 mA(Vp为峰值电压),具有很好的电气特性和广泛的应用场景. To ensure the safety and reliability of the safety level distributed control system(DCS)for live analog signal acquisition,it is necessary to place an isolation distribution device on the front end of the analog acquisition of the DCS.Capacitor charge-discharge was used for analog isolation,and timer and logic gate circuit were used to generate switching control timing signal.The function of isolating the analog signal by using the photoelectric switch,adjusting the charge-discharge time of the capacitor and controlling the timing of the sampling and holding.The isolated voltage signal was converted into a current signal output through the circuit.Through the selection and matching of the parameters of the timing control device,the device has good electrical characteristics and a wide range of application scenarios.Under the condition of uncalibration,the accuracy can reach 0.05%,the temperature drift is less than 2×10-5/℃,and the electrical isolation reaches 1500 Vp@1 min<5 mA(Vp is the peak voltage).
作者 王松 刘明星 赵淄弘 王舜 WANG Song;LIU Mingxing;ZHAO Zihong;WANG Shun(Science and Technology on Reactor System Design Technology Laboratory,Nuclear Power Institute of China,Chengdu 610213,China)
出处 《上海交通大学学报》 EI CAS CSCD 北大核心 2019年第S01期93-97,共5页 Journal of Shanghai Jiaotong University
关键词 模拟量隔离 低温漂 高精度 电容充放电 定时器 采样保持 analog isolation low-temperature drift high-precision capacitor charge-discharge timer sampling and holding
  • 相关文献

参考文献2

二级参考文献3

共引文献4

同被引文献14

引证文献2

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部