期刊文献+

高低温试验箱温度偏差校准结果的测量不确定度评定

Evaluation of measurement uncertainty of calibration results of temperature deviation in high and low temperature test chamber
下载PDF
导出
摘要 高低温试验箱可以为仪表及材料等提供相应的高低温环境,其温度场性能及测量不确定度是影响温度试验箱测量结果的重要指标,通过对温度偏差校准结果的不确定度评定和影响量分析,进一步了解高低温试验箱的计量性能、误差来源及减小误差影响的方法。依据GB/T 10592-2023《高低温试验箱技术条件》规定的校准方法选取满足测量要求的温度传感器,对高低温试验箱温度偏差进行校准。校准确认高低温试验箱温度场性能满足温度偏差±2℃的允差要求,测量不确定度满足1/3最大允许误差的技术指标要求。高低试验箱校准温度场性能良好,测量标准器选取短支A级铂热电阻满足校准要求且稳定性良好符合长时间交替温度的测量使用。 The high and low temperature test chamber can provide the corresponding high and low temperature environment for instruments and materials,and its temperature field performance and measurement uncertainty are important indicators that affect the measurement results of the temperature test chamber.Through the uncertainty evaluation and influence analysis of temperature deviation calibration results,the measurement performance of high and low temperature test chamber,error sources and methods to reduce the influence of error are further understood.According to the calibration method specified in GB/T 10592-2023 Technical Conditions for High and Low Temperature Test Chamber,select the temperature sensor that meets the measurement requirements and calibrate the temperature deviation of the high and low temperature test chamber.The calibration confirms that the temperature field performance of the high and low temperature test chamber meets the tolerance requirement of temperature deviation±2℃,and the measurement uncertainty meets the technical index requirement of 1/3 maximum allowable error.The temperature field performance of the high-low test chamber is good,and the short-branch A-class platinum thermal resistance selected by the measurement standard meets the calibration requirements and has good stability.
作者 赵婷婷 周昭亮 ZHAO Ting-Ting;ZHOU Zhao-Liang(Xi’an Thermal Power Research Institute Co.,Ltd.,Xi’an 710032,China)
出处 《实验室检测》 2024年第7期136-140,共5页 Laboratory Testing
关键词 高低温试验箱 温度偏差 校准 测量不确定度 high and low temperature test chamber temperature deviation calibration measurement uncertainty
  • 相关文献

参考文献15

二级参考文献27

  • 1徐京辉.盐雾试验箱温度计量与调整技术研讨[J].环境技术,1993,11(4):26-29. 被引量:1
  • 2徐京辉.气流式盐雾试验箱技术改进方法研究[J].环境技术,1996,14(2):20-24. 被引量:1
  • 3广州电气科学研究院.GB/T2424.5-2006温度试验箱性能确认(IEC 60068-3-5:2001,IDT)[S].北京:中国标准出版社,2007. 被引量:1
  • 4IEC Technical committee 104. IEC 60068-3-11: 2007 Environmental testing- Part 3-11: Supporting documentation and guidance-calculation of uncertainty of con- ditions in climatic test chambers[S]. 被引量:1
  • 5ISO/TC 69. ISO 3534-2:2006 Statistics - Vocabulary and symbols - Part 2:Applied statistics International Vocabulary of basic and general standard terms in metrology[S]. 被引量:1
  • 6The BIPM etc. ISO/IEC GUIDE 98-3:2008 Uncertainty of measurement - Part 3 Guide to the expression of uncertainty in measurement (GUM: 1995) [S]. 被引量:1
  • 7IEC 60751, Industrial platinum resistance thermometer sensors (IEC, 1995). 被引量:1
  • 8BIPM, IEC, IFCC, ISO, IUPAC, IUPAP, and OIML, Guide to the Expression of Uncertainty in Measurement (International Organization for Standardization, Geneva, Switzerland, 1995), ISBN 92 - 67 - 10188 - 9. 被引量:1
  • 9国家质量技术监督局计量司.测量不确定度评定与表述指南.北京:中国计量出版社,2000. 被引量:1
  • 10国家质量监督检验检疫总局.GB/T5170.2-2008电工电子产品环境试验设备检验方法.温度试验设备.北京:中国标准出版社,2008. 被引量:1