期刊文献+

催化裂化催化剂热崩跑损现象的研究 被引量:21

STUDY ON THE CATALYST LOSS DUE TO THERMO-COLLAPSE IN FCC UNITS
下载PDF
导出
摘要 对两套催化裂化装置补充新鲜催化剂前后三级旋风分离器所回收的催化剂细粉,进行了电子显微照相分析和金属含量、比表面积及微反活性的测定,证实了催化裂化装置在催化剂加入过程中存在热崩现象。在实验室模拟工业装置加新鲜催化剂的环境下,测定了A和B两种催化剂的热崩率,结果表明所测定的催化剂的平均热崩率为10.0%,表观热崩率为8.4%。 It was identified that thermo-collapse occurs when fresh catalysts are added to FCC regenerators by means of scanning electron microscopy(SEM) and of testing the metal contents, specific area and microactivity ( MA ) of the fine catalyst particles from the cyclones of two commercial FCC units. The thermo-collapse rates of the catalysts A and B were determined in laboratory under the conditions similar to those of catalyst addition to an FCC unit. The results showed that the average thermo-collapse rate is 10% and the apparent thermo-collapse rate is 8.4%.
出处 《炼油技术与工程》 CAS 北大核心 2007年第3期1-4,共4页 Petroleum Refinery Engineering
关键词 催化裂化装置 催化剂 热崩 跑损 fluid catalytic cracking unit, catalyst, thermo-collapse, loss
  • 相关文献

参考文献1

  • 1陈俊武,曹汉昌主编..催化裂化工艺与工程[M].北京:中国石化出版社,1995:1035.

同被引文献109

引证文献21

二级引证文献51

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部