This work develops a heuristic method for the design of batch water-using networks of multiple contaminants with regeneration unit based on the concepts of concentration potential. A water-using network involving rege...This work develops a heuristic method for the design of batch water-using networks of multiple contaminants with regeneration unit based on the concepts of concentration potential. A water-using network involving regeneration unit can be formed by adding the regenerated stream(s) into the network involving reuse only. In the design procedure of the network operated in a single batch mode, time is take n as the primary factor a nd con centration potentials as the secondary one. For the networks operated in a repeated mode, the design procedure is similar to that for continuous processes, besides designing the storage tanks with the rules proposed. Continuous regeneration unit is selected in this work. With the proposed method, the network structure corresponding to the minimum freshwater consumption can be obtained. It is shown that the method proposed in this article is simple, effective and has clear engineering meaning.展开更多
基金Supported by the Natural Science Foundation of Hebei Province(B2017202073)the Foundation of Educational Commission of Hebei Province(Z2017032)
文摘This work develops a heuristic method for the design of batch water-using networks of multiple contaminants with regeneration unit based on the concepts of concentration potential. A water-using network involving regeneration unit can be formed by adding the regenerated stream(s) into the network involving reuse only. In the design procedure of the network operated in a single batch mode, time is take n as the primary factor a nd con centration potentials as the secondary one. For the networks operated in a repeated mode, the design procedure is similar to that for continuous processes, besides designing the storage tanks with the rules proposed. Continuous regeneration unit is selected in this work. With the proposed method, the network structure corresponding to the minimum freshwater consumption can be obtained. It is shown that the method proposed in this article is simple, effective and has clear engineering meaning.