Taking wall-flow diesel particulate filter(DPF) as the research objective and separately assuming its filtering wall to be composed of numerous spherical or cylindrical elements, two different mathematical models of s...Taking wall-flow diesel particulate filter(DPF) as the research objective and separately assuming its filtering wall to be composed of numerous spherical or cylindrical elements, two different mathematical models of steady filtration for wall-flow diesel particulate filter were developed and verified by experiments as well as numerically solved. Furthermore, the effects of the macroand micro-structural parameters of filtering wall and exhaust-flow characteristic parameters on trapping efficiency were also analyzed and researched. The results show that: 1) The two developed mathematical models are consistent with the prediction of variation of particulate size; the influence of various factors on the steady trapping efficiency is exactly the same. Compared to model 2, model 1 is more suitable for describing the steady filtration process of wall-flow diesel particulate filter; 2)The major influencing factors on steady trapping efficiency of wall-flow diesel particulate filter are the macro-and micro-structural parameters of filtering wall; and the secondary influencing factors are the exhaust-flow characteristic parameters and macro-structural parameters of filter; 3)The steady trapping efficiency will be improved by increasing filter body volume, pore density as well as wall thickness and by decreasing exhaust-flow, but effects will be weakened when particulate size exceeds a certain critical value; 4) The steady trapping efficiency will be significantly improved by increasing exhaust-flow temperature and filtering wall thickness, but effects will be also weakened when particulate size exceeds a certain critical value; 5) The steady trapping efficiency will approximately linearly increase with reducing porosity, micropore aperture and pore width.展开更多
To simulate steady airflows inside of wall-flow diesel particulate filters (DPF) with different reverse blowing pipes collocation, a mathematical model of the flow in a DPF is established by an equivalent continuum ...To simulate steady airflows inside of wall-flow diesel particulate filters (DPF) with different reverse blowing pipes collocation, a mathematical model of the flow in a DPF is established by an equivalent continuum approach. The experimental results agree well with the theoretical values calculated from the model. Simulation shows that the velocity and the pressure distribution of the filters in the regenerative process are key factors to the filter's regeneration. How to decrease the mal-distribution of the flow in the filter and how to achieve the better regenerative performance at the least cost of air consumption in the regenerative process are the ultimate goals of the study. Calculation and experiments show that the goals can be realized through adjusting the angle of two reverse blowing pipes and their relative location suitably.展开更多
基金Projects(5117604551276056)supported by the National Natural Science Foundation of China+1 种基金Projects(201208430262201306130031)supported by the National Studying Abroad Foundation of the China Scholarship Council
文摘Taking wall-flow diesel particulate filter(DPF) as the research objective and separately assuming its filtering wall to be composed of numerous spherical or cylindrical elements, two different mathematical models of steady filtration for wall-flow diesel particulate filter were developed and verified by experiments as well as numerically solved. Furthermore, the effects of the macroand micro-structural parameters of filtering wall and exhaust-flow characteristic parameters on trapping efficiency were also analyzed and researched. The results show that: 1) The two developed mathematical models are consistent with the prediction of variation of particulate size; the influence of various factors on the steady trapping efficiency is exactly the same. Compared to model 2, model 1 is more suitable for describing the steady filtration process of wall-flow diesel particulate filter; 2)The major influencing factors on steady trapping efficiency of wall-flow diesel particulate filter are the macro-and micro-structural parameters of filtering wall; and the secondary influencing factors are the exhaust-flow characteristic parameters and macro-structural parameters of filter; 3)The steady trapping efficiency will be improved by increasing filter body volume, pore density as well as wall thickness and by decreasing exhaust-flow, but effects will be weakened when particulate size exceeds a certain critical value; 4) The steady trapping efficiency will be significantly improved by increasing exhaust-flow temperature and filtering wall thickness, but effects will be also weakened when particulate size exceeds a certain critical value; 5) The steady trapping efficiency will approximately linearly increase with reducing porosity, micropore aperture and pore width.
基金This project is supported by National Hi-tech Research and DevelopmentProgram of China (863 Program, No.2003AA643010B).
文摘To simulate steady airflows inside of wall-flow diesel particulate filters (DPF) with different reverse blowing pipes collocation, a mathematical model of the flow in a DPF is established by an equivalent continuum approach. The experimental results agree well with the theoretical values calculated from the model. Simulation shows that the velocity and the pressure distribution of the filters in the regenerative process are key factors to the filter's regeneration. How to decrease the mal-distribution of the flow in the filter and how to achieve the better regenerative performance at the least cost of air consumption in the regenerative process are the ultimate goals of the study. Calculation and experiments show that the goals can be realized through adjusting the angle of two reverse blowing pipes and their relative location suitably.