In high-speed cutting, natural thermocouple, artificial thermocouple and infrared radiation temperature measurement are usually adopted for measuring cutting temperature, but these methods have difficulty in measuring...In high-speed cutting, natural thermocouple, artificial thermocouple and infrared radiation temperature measurement are usually adopted for measuring cutting temperature, but these methods have difficulty in measuring transient temperature accurately of cutting area on account of low response speed and limited cutting condition. In this paper, NiCr/NiSi thin-film thermocouples(TFTCs) are fabricated according to temperature characteristic of cutting area in high-speed cutting by means of advanced twinned microwave electro cyclotron resonance(MW-ECR) plasma source enhanced radio frequency(RF) reaction non-balance magnetron sputtering technique, and can be used for transient cutting temperature measurement. The time constants of the TFTCs with different thermo-junction film width are measured at four kinds of sampling frequency by using Ultra-CFR short pulsed laser system that established. One-dimensional unsteady heat conduction model is constructed and the dynamic performance is analyzed theoretically. It can be seen from the analysis results that the NiCr/NiSi TFTCs are suitable for measuring transient temperature which varies quickly, the response speed of TFTCs can be obviously improved by reducing the thickness of thin-film, and the area of thermo-junction has little influence on dynamic response time. The dynamic calibration experiments are made on the constructed dynamic calibration system, and the experimental results confirm that sampling frequency should be larger than 50 kHz in dynamic measurement for stable response time, and the shortest response time is 0.042 ms. Measurement methods and devices of cutting heat and cutting temperature measurement are developed and improved by this research, which provide practical methods and instruments in monitoring cutting heat and cutting temperature for research and production in high-speed machining.展开更多
Thin film thermocouples(TFTCs) can provide fast and accurate surface temperature measurement with minimal impact on the physical characteristics of the supporting components. In this study, NiCr and NiSi films were ...Thin film thermocouples(TFTCs) can provide fast and accurate surface temperature measurement with minimal impact on the physical characteristics of the supporting components. In this study, NiCr and NiSi films were prepared with radio frequency(RF) magnetron sputtering and the influences of vacuum annealing on the resistivity of the films were investigated. Afterward, NiCr-NiSi films were deposited on Ni-based superalloy substrates to form TFTCs. The overall dimension of the thermocouple is 64 mm in length, 8 mm in width and 30 lm in thickness. Compared with those of as-deposited sample, the thermoelectric property and stability of the TFTC are significantly improved by vacuum annealing of NiCr and NiSi films. The variation of the Seebeck coefficient of TFTC was discussed based on the size effect of NiCr and NiSi films. And a lower Seebeck coefficient of TFTC of 38.4 μV·℃^-1 is obtained.展开更多
基金supported by National Natural Science Foundation of China(Grant No.50775210)Liaoning Provincial Natural Science Foundation of China(Grant No.20062143)Liaoning Provincial Universities Science and Technology Program of China(Grant No.05L023)
文摘In high-speed cutting, natural thermocouple, artificial thermocouple and infrared radiation temperature measurement are usually adopted for measuring cutting temperature, but these methods have difficulty in measuring transient temperature accurately of cutting area on account of low response speed and limited cutting condition. In this paper, NiCr/NiSi thin-film thermocouples(TFTCs) are fabricated according to temperature characteristic of cutting area in high-speed cutting by means of advanced twinned microwave electro cyclotron resonance(MW-ECR) plasma source enhanced radio frequency(RF) reaction non-balance magnetron sputtering technique, and can be used for transient cutting temperature measurement. The time constants of the TFTCs with different thermo-junction film width are measured at four kinds of sampling frequency by using Ultra-CFR short pulsed laser system that established. One-dimensional unsteady heat conduction model is constructed and the dynamic performance is analyzed theoretically. It can be seen from the analysis results that the NiCr/NiSi TFTCs are suitable for measuring transient temperature which varies quickly, the response speed of TFTCs can be obviously improved by reducing the thickness of thin-film, and the area of thermo-junction has little influence on dynamic response time. The dynamic calibration experiments are made on the constructed dynamic calibration system, and the experimental results confirm that sampling frequency should be larger than 50 kHz in dynamic measurement for stable response time, and the shortest response time is 0.042 ms. Measurement methods and devices of cutting heat and cutting temperature measurement are developed and improved by this research, which provide practical methods and instruments in monitoring cutting heat and cutting temperature for research and production in high-speed machining.
基金financially supported by the National Natural Science Foundation of China (No.61223002)Sichuan Youth Science and Technology Innovation Research Team Funding (No.2011JTD0006)Program for Cooperation of Industry, Education and Academy of Guangdong Province, China (No.2013B090400001)
文摘Thin film thermocouples(TFTCs) can provide fast and accurate surface temperature measurement with minimal impact on the physical characteristics of the supporting components. In this study, NiCr and NiSi films were prepared with radio frequency(RF) magnetron sputtering and the influences of vacuum annealing on the resistivity of the films were investigated. Afterward, NiCr-NiSi films were deposited on Ni-based superalloy substrates to form TFTCs. The overall dimension of the thermocouple is 64 mm in length, 8 mm in width and 30 lm in thickness. Compared with those of as-deposited sample, the thermoelectric property and stability of the TFTC are significantly improved by vacuum annealing of NiCr and NiSi films. The variation of the Seebeck coefficient of TFTC was discussed based on the size effect of NiCr and NiSi films. And a lower Seebeck coefficient of TFTC of 38.4 μV·℃^-1 is obtained.