本文以直流环形配电网为研究对象,深入分析了当直流线路发生接地故障时直流侧电压的故障特性,并据此提出了基于局部测量的直流配电网故障检测的保护方案。该方案以过电流保护和电流变化率保护为启动判据,并利用二次时变函数来预测故障...本文以直流环形配电网为研究对象,深入分析了当直流线路发生接地故障时直流侧电压的故障特性,并据此提出了基于局部测量的直流配电网故障检测的保护方案。该方案以过电流保护和电流变化率保护为启动判据,并利用二次时变函数来预测故障时的线路侧电压,以故障时刻线路侧的预测电压和实测电压的差值作为主保护动作依据,配备欠压保护为后备保护以确保在故障情况下环形直流配电网能够安全稳定运行。本文增加了补充判据,进一步区分区内故障和区外故障,防止保护误动作。基于实时数字仿真器RTDS(real time digital simulator)对环形直流配电网保护方案进行仿真研究,验证了所提方案的可行性与有效性。展开更多
Finite control set-model predictive control (FCS-MPC) is employed in this paper to control the operation of a three-phase grid-connected string inverter based on a direct PQ control scheme. The main objective is to ac...Finite control set-model predictive control (FCS-MPC) is employed in this paper to control the operation of a three-phase grid-connected string inverter based on a direct PQ control scheme. The main objective is to achieve high-performance decoupled control of the active and reactive powers injected to the grid from distributed energy resources (DER).The FCS-MPC scheme instantaneously searches for and applies the optimum inverter switching state that can achieve certain goals, such as minimum deviation between reference and actual power;so that both power components (P and Q) are well controlled to their reference values.In addition, an effective method to attenuate undesired cross coupling between the P and Q control loops, which occurs only during transient operation, is investigated. The proposed method is based on the variation of the weight factors of the terms of the FCS-MPC cost function, so a higher weight factor is assigned to the cost function term that is exposed to greater disturbance. Empirical formulae of optimum weight factors as functions of the reference active and reactive power signals are proposed and mathematically derived. The investigated FCS-MPC control scheme is incorporated with the LVRT function to support the grid voltage in fulfilling and accomplishing the up-to-date grid codes. The LVRT algorithm is based on a modification of the references of active and reactive powers as functions of the instantaneous grid voltage such that suitable values of P and Q are injected to the grid during voltage sag.The performance of the elaborated FCS-MPC PQ scheme is studied under various operating scenarios, including steady-state and transient conditions. Results demonstrate the validity and effectiveness of the proposed scheme with regard to the achievement of high-performance operation and quick response of grid-tied inverters during normal and fault modes.展开更多
This paper presents an improved finite control set model predictive current control(FCS-MPCC)of a five-phase permanent magnet synchronous motor(PMSM).First,to avoid including all the 32 voltage vectors provided by a t...This paper presents an improved finite control set model predictive current control(FCS-MPCC)of a five-phase permanent magnet synchronous motor(PMSM).First,to avoid including all the 32 voltage vectors provided by a two-level five-phase inverter into the control set,virtual voltage vectors are adopted.As the third current harmonics can be much reduced by virtual voltage vectors automatically,the harmonic items in the cost function of conventional FCS-MPCC are not considered.Furthermore,an adaptive control set is proposed based on voltage prediction.Best control set with proper voltage vector amplitude corresponding to different rotor speed can be achieved by this method.Consequently,current ripples can be largely reduced and the system performs much better.At last,simulations are established to verify the steady and transient performance of the proposed FCS-MPCC,and experiments based on a 2 kW five-phase motor are carried out.The results have validated the performance improvement of the proposed control strategy.展开更多
This paper proposes a new concept of synthesized voltage vector to address dead-time effect issue for Finite Control Set Model Predictive Control(FCS-MPC)technique.For a voltage source inverter(VSI),dead-time is inevi...This paper proposes a new concept of synthesized voltage vector to address dead-time effect issue for Finite Control Set Model Predictive Control(FCS-MPC)technique.For a voltage source inverter(VSI),dead-time is inevitably inserted between the turn off and turn on instants of power devices to avoid short circuit phenomenon.The influence of dead-time leads to output voltage vector error of three-phase inverters.Furthermore,it will result in computing deviation in cost function,and will deteriorate the performance of the system if not properly dealt with.In this paper,the problem is clearly analyzed,and the solution to this issue is proposed by introducing a synthesized voltage vector.The proposed solution is verified by Hardware-in-the-loop(HiL)test in real time,and results validate the effectiveness of the proposed solution.展开更多
In this paper,distributed model predictive control(DMPC) for island DC micro-grids(MG) with wind/photovoltaic(PV)/battery power is proposed,which coordinates all distributed generations(DG) to stabilize the bus voltag...In this paper,distributed model predictive control(DMPC) for island DC micro-grids(MG) with wind/photovoltaic(PV)/battery power is proposed,which coordinates all distributed generations(DG) to stabilize the bus voltage together with the insurance of having computational efficiency under a real-time requirement.Based on the feedback of the bus voltage,the deviation of the current is dispatched to each DG according to cost over the prediction horizon.Moreover,to avoid the excessive fluctuation of the battery power,both the discharge-charge switching times and costs are considered in the model predictive control(MPC) optimization problems.A Lyapunov constraint with a time-varying steady-state is designed in each local MPC to guarantee the stabilization of the entire system.The voltage stabilization of the MG is achieved by this strategy with the cooperation of DGs.The numeric results of applying the proposed method to a MG of the Shanghai Power Supply Company shows the effectiveness of the distributed economic MPC.展开更多
This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optima...This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optimal voltage vector dynamically through the space vector plane.Therefore,the proposed DS-MPC strategy could ensure dynamic performance and steady-state performance as well.Also,the current control robustness can be improved through DS-MPC with disturbance observer(DO)based on the extended Kalman filter(EKF).The novelty of this control is that the current control with fast dynamic response can be realized in the weak grid,even if the grid voltages are greatly distorted.Simulation and hardware experiments on the weak grid validate the effectiveness of the proposed DS-MPC with the EKF observer approach.展开更多
This paper describes the integration of a photovoltaic (PV) renewable energy source with a superconducting magnetic energy storage (SMES) system. The integrated system can improve the voltage stability of the utility ...This paper describes the integration of a photovoltaic (PV) renewable energy source with a superconducting magnetic energy storage (SMES) system. The integrated system can improve the voltage stability of the utility grid and achieve power leveling. The control schemes employ model predictive control (MPC), which has gained significant attention in recent years because of its advantages such as fast response and simple implementation. The PV system provides maximum power at various irradiation levels using the incremental conductance technique (INC). The interfaced grid side converter of the SMES can control the grid voltage by regulating its injected reactive power to the grid, while the charge and discharge operation of the SMES coil can be managed by the system operator to inject/absorb active power to/from the grid to achieve the power leveling strategy. Simulation results based on MATLAB/Simulink® software prove the fast response of the system control objectives in tracking the setpoints at different loading scenarios and PV irradiance levels, while the SMES injects/absorbs active and reactive power to/from the grid during various events to improve the voltage response and achieve power leveling strategy.展开更多
This paper presents a machine-learning-based speedup strategy for real-time implementation of model-predictive-control(MPC)in emergency voltage stabilization of power systems.Despite success in various applications,re...This paper presents a machine-learning-based speedup strategy for real-time implementation of model-predictive-control(MPC)in emergency voltage stabilization of power systems.Despite success in various applications,real-time implementation of MPC in power systems has not been successful due to the online control computation time required for large-sized complex systems,and in power systems,the computation time exceeds the available decision time used in practice by a large extent.This long-standing problem is addressed here by developing a novel MPC-based framework that i)computes an optimal strategy for nominal loads in an offline setting and adapts it for real-time scenarios by successive online control corrections at each control instant utilizing the latest measurements,and ii)employs a machine-learning based approach for the prediction of voltage trajectory and its sensitivity to control inputs,thereby accelerating the overall control computation by multiple times.Additionally,a realistic control coordination scheme among static var compensators(SVC),load-shedding(LS),and load tap-changers(LTC)is presented that incorporates the practical delayed actions of the LTCs.The performance of the proposed scheme is validated for IEEE 9-bus and 39-bus systems,with±20%variations in nominal loading conditions together with contingencies.We show that our proposed methodology speeds up the online computation by 20-fold,bringing it down to a practically feasible value(fraction of a second),making the MPC real-time and feasible for power system control for the first time.展开更多
In this study,a coordinated voltage control strategy based on model predictive control(MPC)is proposed for offshore radial DC-connected wind farms.Two control modes are designed in this strategy.In the economic operat...In this study,a coordinated voltage control strategy based on model predictive control(MPC)is proposed for offshore radial DC-connected wind farms.Two control modes are designed in this strategy.In the economic operation mode,the wind farm controller generates optimal active power references as well as bus voltage references of medium-voltage collector for DC-connected wind turbine(DCWT)systems and high-voltage DC/DC converters,where the goal is to minimize power losses inside the wind farm and ensure that voltages are within a feasible range,all while tracking the power references.In the voltage control mode,the main control objective for the wind farm controller is to minimize voltage deviations from the rated voltage.With the MPC,the control objective and operation constraints can be explicitly represented in the optimization problem while considering the dynamic response of the DCWT system.In addition,a sensitivity coefficient calculation method for radial DC-connected wind farms is developed to improve computational efficiency.Finally,DC-connected wind farms with 20 wind turbines are used to demonstrate the performance of the proposed strategy.展开更多
To address the problem of insufficient system inertia and improve the power quality of grid-connected inverters,and to enhance the stability of the power system,a method to control a virtual synchronous generator(VSG)...To address the problem of insufficient system inertia and improve the power quality of grid-connected inverters,and to enhance the stability of the power system,a method to control a virtual synchronous generator(VSG)output voltage based on model predictive control(MPC)is proposed.Parameters of the inductors,capacitors and other components of the VSG can vary as the temperature and current changes.Consequently the VSG output voltage and power control accuracy using the conventional MPC method may be reduced.In this paper,to improve the parameter robustness of the MPC method,a new weighted predictive capacitor voltage control method is proposed.Through detailed theoretical analysis,the principle of the proposed method to reduce the influence of parameter errors on voltage tracking accuracy is analyzed.Finally,the effectiveness and feasibility of the proposed method are verified by experimental tests using the Typhoon control hardware-in-the-loop experimental platform.展开更多
To further improve the steady-state performance of the conventional dual vector model predictive current control(MPCC),an improved optimal duty MPCC strategy for permanent magnet synchronous motor(PMSM)is proposed.Thi...To further improve the steady-state performance of the conventional dual vector model predictive current control(MPCC),an improved optimal duty MPCC strategy for permanent magnet synchronous motor(PMSM)is proposed.This strategy is realized by selecting an optimal voltage vector combination and its duration from the five basic voltage vector combinations,followed by acting on the inverter.The five combinations are:the combination of the optimal voltage vector at the previous moment and basic voltage vector with an angle difference of 60°;the combination of the optimal voltage vector at the previous moment and basic voltage vector with an angle difference of-60°;the combination of the aforementioned three basic voltage vectors with the zero vector.Experimental results indicate that the method effectively reduces the stator current ripple without increasing the calculational burden.Furthermore,it improves the steady-state performance of the system without altering the dynamic performance of the system.展开更多
文摘本文以直流环形配电网为研究对象,深入分析了当直流线路发生接地故障时直流侧电压的故障特性,并据此提出了基于局部测量的直流配电网故障检测的保护方案。该方案以过电流保护和电流变化率保护为启动判据,并利用二次时变函数来预测故障时的线路侧电压,以故障时刻线路侧的预测电压和实测电压的差值作为主保护动作依据,配备欠压保护为后备保护以确保在故障情况下环形直流配电网能够安全稳定运行。本文增加了补充判据,进一步区分区内故障和区外故障,防止保护误动作。基于实时数字仿真器RTDS(real time digital simulator)对环形直流配电网保护方案进行仿真研究,验证了所提方案的可行性与有效性。
文摘Finite control set-model predictive control (FCS-MPC) is employed in this paper to control the operation of a three-phase grid-connected string inverter based on a direct PQ control scheme. The main objective is to achieve high-performance decoupled control of the active and reactive powers injected to the grid from distributed energy resources (DER).The FCS-MPC scheme instantaneously searches for and applies the optimum inverter switching state that can achieve certain goals, such as minimum deviation between reference and actual power;so that both power components (P and Q) are well controlled to their reference values.In addition, an effective method to attenuate undesired cross coupling between the P and Q control loops, which occurs only during transient operation, is investigated. The proposed method is based on the variation of the weight factors of the terms of the FCS-MPC cost function, so a higher weight factor is assigned to the cost function term that is exposed to greater disturbance. Empirical formulae of optimum weight factors as functions of the reference active and reactive power signals are proposed and mathematically derived. The investigated FCS-MPC control scheme is incorporated with the LVRT function to support the grid voltage in fulfilling and accomplishing the up-to-date grid codes. The LVRT algorithm is based on a modification of the references of active and reactive powers as functions of the instantaneous grid voltage such that suitable values of P and Q are injected to the grid during voltage sag.The performance of the elaborated FCS-MPC PQ scheme is studied under various operating scenarios, including steady-state and transient conditions. Results demonstrate the validity and effectiveness of the proposed scheme with regard to the achievement of high-performance operation and quick response of grid-tied inverters during normal and fault modes.
基金This work was supported in part by the National Natural Science Foundation of China under 61374125。
文摘This paper presents an improved finite control set model predictive current control(FCS-MPCC)of a five-phase permanent magnet synchronous motor(PMSM).First,to avoid including all the 32 voltage vectors provided by a two-level five-phase inverter into the control set,virtual voltage vectors are adopted.As the third current harmonics can be much reduced by virtual voltage vectors automatically,the harmonic items in the cost function of conventional FCS-MPCC are not considered.Furthermore,an adaptive control set is proposed based on voltage prediction.Best control set with proper voltage vector amplitude corresponding to different rotor speed can be achieved by this method.Consequently,current ripples can be largely reduced and the system performs much better.At last,simulations are established to verify the steady and transient performance of the proposed FCS-MPCC,and experiments based on a 2 kW five-phase motor are carried out.The results have validated the performance improvement of the proposed control strategy.
文摘This paper proposes a new concept of synthesized voltage vector to address dead-time effect issue for Finite Control Set Model Predictive Control(FCS-MPC)technique.For a voltage source inverter(VSI),dead-time is inevitably inserted between the turn off and turn on instants of power devices to avoid short circuit phenomenon.The influence of dead-time leads to output voltage vector error of three-phase inverters.Furthermore,it will result in computing deviation in cost function,and will deteriorate the performance of the system if not properly dealt with.In this paper,the problem is clearly analyzed,and the solution to this issue is proposed by introducing a synthesized voltage vector.The proposed solution is verified by Hardware-in-the-loop(HiL)test in real time,and results validate the effectiveness of the proposed solution.
基金supported by the National Key R&D Program of China (2018AAA0101701)the National Natural Science Foundation of China (62073220,61833012)。
文摘In this paper,distributed model predictive control(DMPC) for island DC micro-grids(MG) with wind/photovoltaic(PV)/battery power is proposed,which coordinates all distributed generations(DG) to stabilize the bus voltage together with the insurance of having computational efficiency under a real-time requirement.Based on the feedback of the bus voltage,the deviation of the current is dispatched to each DG according to cost over the prediction horizon.Moreover,to avoid the excessive fluctuation of the battery power,both the discharge-charge switching times and costs are considered in the model predictive control(MPC) optimization problems.A Lyapunov constraint with a time-varying steady-state is designed in each local MPC to guarantee the stabilization of the entire system.The voltage stabilization of the MG is achieved by this strategy with the cooperation of DGs.The numeric results of applying the proposed method to a MG of the Shanghai Power Supply Company shows the effectiveness of the distributed economic MPC.
文摘This paper proposes a robust dichotomy-based model predictive control(DS-MPC)with a fixed switching frequency for the grid-connected inverter(GCI).The proposed fast dichotomy algorithm can select and deduce the optimal voltage vector dynamically through the space vector plane.Therefore,the proposed DS-MPC strategy could ensure dynamic performance and steady-state performance as well.Also,the current control robustness can be improved through DS-MPC with disturbance observer(DO)based on the extended Kalman filter(EKF).The novelty of this control is that the current control with fast dynamic response can be realized in the weak grid,even if the grid voltages are greatly distorted.Simulation and hardware experiments on the weak grid validate the effectiveness of the proposed DS-MPC with the EKF observer approach.
基金supported in part by the Estonian Research Council grant PSG206in part by the Estonian Centre of Excellence in Zero Energy and Resource Efficient Smart Buildings and Districts,ZEBE,grant 2014-2020.4.01.15-0016 funded by the European Regional Development Fund.
文摘This paper describes the integration of a photovoltaic (PV) renewable energy source with a superconducting magnetic energy storage (SMES) system. The integrated system can improve the voltage stability of the utility grid and achieve power leveling. The control schemes employ model predictive control (MPC), which has gained significant attention in recent years because of its advantages such as fast response and simple implementation. The PV system provides maximum power at various irradiation levels using the incremental conductance technique (INC). The interfaced grid side converter of the SMES can control the grid voltage by regulating its injected reactive power to the grid, while the charge and discharge operation of the SMES coil can be managed by the system operator to inject/absorb active power to/from the grid to achieve the power leveling strategy. Simulation results based on MATLAB/Simulink® software prove the fast response of the system control objectives in tracking the setpoints at different loading scenarios and PV irradiance levels, while the SMES injects/absorbs active and reactive power to/from the grid during various events to improve the voltage response and achieve power leveling strategy.
基金This work was supported in part by the National Science Foundation(NSF-CSSI-2004766,NSF-PFI-2141084).
文摘This paper presents a machine-learning-based speedup strategy for real-time implementation of model-predictive-control(MPC)in emergency voltage stabilization of power systems.Despite success in various applications,real-time implementation of MPC in power systems has not been successful due to the online control computation time required for large-sized complex systems,and in power systems,the computation time exceeds the available decision time used in practice by a large extent.This long-standing problem is addressed here by developing a novel MPC-based framework that i)computes an optimal strategy for nominal loads in an offline setting and adapts it for real-time scenarios by successive online control corrections at each control instant utilizing the latest measurements,and ii)employs a machine-learning based approach for the prediction of voltage trajectory and its sensitivity to control inputs,thereby accelerating the overall control computation by multiple times.Additionally,a realistic control coordination scheme among static var compensators(SVC),load-shedding(LS),and load tap-changers(LTC)is presented that incorporates the practical delayed actions of the LTCs.The performance of the proposed scheme is validated for IEEE 9-bus and 39-bus systems,with±20%variations in nominal loading conditions together with contingencies.We show that our proposed methodology speeds up the online computation by 20-fold,bringing it down to a practically feasible value(fraction of a second),making the MPC real-time and feasible for power system control for the first time.
文摘In this study,a coordinated voltage control strategy based on model predictive control(MPC)is proposed for offshore radial DC-connected wind farms.Two control modes are designed in this strategy.In the economic operation mode,the wind farm controller generates optimal active power references as well as bus voltage references of medium-voltage collector for DC-connected wind turbine(DCWT)systems and high-voltage DC/DC converters,where the goal is to minimize power losses inside the wind farm and ensure that voltages are within a feasible range,all while tracking the power references.In the voltage control mode,the main control objective for the wind farm controller is to minimize voltage deviations from the rated voltage.With the MPC,the control objective and operation constraints can be explicitly represented in the optimization problem while considering the dynamic response of the DCWT system.In addition,a sensitivity coefficient calculation method for radial DC-connected wind farms is developed to improve computational efficiency.Finally,DC-connected wind farms with 20 wind turbines are used to demonstrate the performance of the proposed strategy.
基金supported in part by the National Natural Science Foundation of China(51707176)in part by the Youth Talent Support Project of Henan Province(2019HYTP021)+1 种基金in part by the Youth Talent Support Project of Henan Province(2019HYTP021)in part by the Key Research,Development and Promotion Special Project(Science and Technology)of Henan Province(202102210103).
文摘To address the problem of insufficient system inertia and improve the power quality of grid-connected inverters,and to enhance the stability of the power system,a method to control a virtual synchronous generator(VSG)output voltage based on model predictive control(MPC)is proposed.Parameters of the inductors,capacitors and other components of the VSG can vary as the temperature and current changes.Consequently the VSG output voltage and power control accuracy using the conventional MPC method may be reduced.In this paper,to improve the parameter robustness of the MPC method,a new weighted predictive capacitor voltage control method is proposed.Through detailed theoretical analysis,the principle of the proposed method to reduce the influence of parameter errors on voltage tracking accuracy is analyzed.Finally,the effectiveness and feasibility of the proposed method are verified by experimental tests using the Typhoon control hardware-in-the-loop experimental platform.
基金Supported by the National Natural Science Foundation of China(51907061)Natural Science Foundation of Hunan Province(2019JJ50119)National Engineering Laboratory of UHV Engineering Technology(Kunming,Guangzhou)(NEL202008)。
文摘To further improve the steady-state performance of the conventional dual vector model predictive current control(MPCC),an improved optimal duty MPCC strategy for permanent magnet synchronous motor(PMSM)is proposed.This strategy is realized by selecting an optimal voltage vector combination and its duration from the five basic voltage vector combinations,followed by acting on the inverter.The five combinations are:the combination of the optimal voltage vector at the previous moment and basic voltage vector with an angle difference of 60°;the combination of the optimal voltage vector at the previous moment and basic voltage vector with an angle difference of-60°;the combination of the aforementioned three basic voltage vectors with the zero vector.Experimental results indicate that the method effectively reduces the stator current ripple without increasing the calculational burden.Furthermore,it improves the steady-state performance of the system without altering the dynamic performance of the system.