It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of sing...It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of single-phase earth fault current distribution and case verification were accomplished by using the loop method.Influences of some factors,such as single-phase earth fault location and ground resistance of poles,on short-circuit current distribution were discussed.Results show that:1) results of the loop method conform to those of double sided elimination method;2) the fault location hardly influences macro-distribution of short-circuit current.However,current near fault location is evidently influenced;and 3) the short-circuit current distribution is not so sensitive to the ground resistance of poles.展开更多
光纤复合架空地线(OPGW)故障频发的原因与光缆局部受到的应力有直接关系,为了实现对OPGW光缆的在线应变监测,搭建了长距离布里渊光时域分析(BOTDA)和布里渊光时域反射(BOTDR)系统,并对重覆冰区域运行年限超过15年的在运95.14 km OPGW进...光纤复合架空地线(OPGW)故障频发的原因与光缆局部受到的应力有直接关系,为了实现对OPGW光缆的在线应变监测,搭建了长距离布里渊光时域分析(BOTDA)和布里渊光时域反射(BOTDR)系统,并对重覆冰区域运行年限超过15年的在运95.14 km OPGW进行了应变检测和分析。通过对同一段光缆的对比测量,结果表明:BOTDA系统具有更长的测量距离、更高的空间分辨率与更高的测量精度,能准确辨别引下线并识别零应变参考点,可以实现温度和应变信息的准确分离。在两个站点的距离超过BOTDA系统的测量量程时,可以使用BOTDR系统从光缆两端分别测量以覆盖全部光缆。同时,BOTDR系统展现出单端测量的优势,在断纤故障发生时,BOTDR系统可不影响断点之前的线路测量。在同一条OPGW光缆线路上通过多维度的对比,分析了两种技术在OPGW光缆监测中的优劣势,为分布式光纤传感技术在电力系统中的应用提供参考。展开更多
为满足光纤复合架空地线(OPGW)直流融冰的需要,同时解决环流损耗和易遭雷击断股等问题,须将OPGW接地方式由目前常用的逐塔接地改造为分段或全线绝缘、单点接地方式;OPGW经地线绝缘子及其并联放电间隙与杆塔相连。为此,提出了OPGW直流融...为满足光纤复合架空地线(OPGW)直流融冰的需要,同时解决环流损耗和易遭雷击断股等问题,须将OPGW接地方式由目前常用的逐塔接地改造为分段或全线绝缘、单点接地方式;OPGW经地线绝缘子及其并联放电间隙与杆塔相连。为此,提出了OPGW直流融冰绝缘化改造对并联放电间隙的电气要求,分别对正常运行时、地线直流融冰条件下和雷击情况下的并联放电间隙电气性能进行了详细的计算分析和试验研究。结果表明:并联放电间隙距离选择应满足感应电压和直流融冰电压的耐受要求,还应保证并联放电间隙在雷电过电压下可靠击穿;要满足工频感应电压的耐受要求,间隙距离可取20~100 mm;要满足直流融冰电压为-20 k V×(1±10%)的耐受要求,间隙距离应大于60 mm;考虑到间隙放电的分散性,间隙距离宜适当增大,推荐值为70~80 mm;70~80 mm间隙距离的雷电冲击放电电压一般不大于100 k V,线路遭受雷击时,地线绝缘子与并联放电间隙所承受的电压至少为885 k V,甚至高达数MV,并联放电间隙能可靠击穿,从而确保地线绝缘子的运行安全性。该研究结果可为OPGW直流融冰绝缘化改造提供理论支撑和数据支持。展开更多
文摘It is important for the safety of transmission system to accurately calculate single-phase earth fault current distribution.Features of double sided elimination method were illustrated.Quantitative calculation of single-phase earth fault current distribution and case verification were accomplished by using the loop method.Influences of some factors,such as single-phase earth fault location and ground resistance of poles,on short-circuit current distribution were discussed.Results show that:1) results of the loop method conform to those of double sided elimination method;2) the fault location hardly influences macro-distribution of short-circuit current.However,current near fault location is evidently influenced;and 3) the short-circuit current distribution is not so sensitive to the ground resistance of poles.
文摘光纤复合架空地线(OPGW)故障频发的原因与光缆局部受到的应力有直接关系,为了实现对OPGW光缆的在线应变监测,搭建了长距离布里渊光时域分析(BOTDA)和布里渊光时域反射(BOTDR)系统,并对重覆冰区域运行年限超过15年的在运95.14 km OPGW进行了应变检测和分析。通过对同一段光缆的对比测量,结果表明:BOTDA系统具有更长的测量距离、更高的空间分辨率与更高的测量精度,能准确辨别引下线并识别零应变参考点,可以实现温度和应变信息的准确分离。在两个站点的距离超过BOTDA系统的测量量程时,可以使用BOTDR系统从光缆两端分别测量以覆盖全部光缆。同时,BOTDR系统展现出单端测量的优势,在断纤故障发生时,BOTDR系统可不影响断点之前的线路测量。在同一条OPGW光缆线路上通过多维度的对比,分析了两种技术在OPGW光缆监测中的优劣势,为分布式光纤传感技术在电力系统中的应用提供参考。
文摘为满足光纤复合架空地线(OPGW)直流融冰的需要,同时解决环流损耗和易遭雷击断股等问题,须将OPGW接地方式由目前常用的逐塔接地改造为分段或全线绝缘、单点接地方式;OPGW经地线绝缘子及其并联放电间隙与杆塔相连。为此,提出了OPGW直流融冰绝缘化改造对并联放电间隙的电气要求,分别对正常运行时、地线直流融冰条件下和雷击情况下的并联放电间隙电气性能进行了详细的计算分析和试验研究。结果表明:并联放电间隙距离选择应满足感应电压和直流融冰电压的耐受要求,还应保证并联放电间隙在雷电过电压下可靠击穿;要满足工频感应电压的耐受要求,间隙距离可取20~100 mm;要满足直流融冰电压为-20 k V×(1±10%)的耐受要求,间隙距离应大于60 mm;考虑到间隙放电的分散性,间隙距离宜适当增大,推荐值为70~80 mm;70~80 mm间隙距离的雷电冲击放电电压一般不大于100 k V,线路遭受雷击时,地线绝缘子与并联放电间隙所承受的电压至少为885 k V,甚至高达数MV,并联放电间隙能可靠击穿,从而确保地线绝缘子的运行安全性。该研究结果可为OPGW直流融冰绝缘化改造提供理论支撑和数据支持。