AIM: To evaluate the reproducibility of a modified 13^C breath test-based measurement of solid phase gastric emptying (GE) within the frames of a simple-repeated measure study protocol. METHODS: Twelve healthy sub...AIM: To evaluate the reproducibility of a modified 13^C breath test-based measurement of solid phase gastric emptying (GE) within the frames of a simple-repeated measure study protocol. METHODS: Twelve healthy subjects (6 females and 6 males, mean age 24.9+0.7 years) were recruited to undergo three identical GE examinations. In six subjects the first two examinations were performed 2 d apart, and the third session was carried out at a median interval of 19.5 d (range 18 - 20 d) from the second one. In another six subjects the first two measurements were taken 20 d apart (median, range: 17-23 d), whereas the third session took place 2 d after the second one. Probes of expiratory air collected before and during six hours after intake of a solid meal (378 kcal) labelled with 75 μL (68 mg) 13^C-octanoic acid, were measured for 13^CO2 enrichment with the nondispersive isotopeselective infrared spectrometry NDIRS apparatus. RESULTS: Taking coefficients of variation for paired examinations into account, the short-term reproducibility of the GE measurement was slightly but not significantly better than the medium-term one: 7.7% and 11.2% for the lag phase (T-Lag), 7.3% and 10.9% for the gastric half emptying time (T1/2). The least differences in GE parameters detectable at P= 0.05 level in the 12 paired examinations were 9.6 and 15.6 min for T-Lag, 11.6 and 19.7 min for T1/2 by a two-day or two to three-week time gap, respectively CONCLUSION: The low-cost modification of the breath test involving a lower dose of 13^C-octanoic acid and NDIRS, renders good short- and medium-term reproducibility, as well as sensitivity of the measurement of gastric emptying of solids.展开更多
In recent years, since thousands of new chemicals have been produced and put into the environment, it is important for us to screen the chemicals which have potential toxicity. So QSAR (quantitative structure-activity...In recent years, since thousands of new chemicals have been produced and put into the environment, it is important for us to screen the chemicals which have potential toxicity. So QSAR (quantitative structure-activity relationship) has been widely used.展开更多
基金Supported by a research grant(3 P05D 054 24)from the Ministry of Scientific Research and Information Technology(formerly:State Committee For Scientific Research)of the Republic of Poland-contract #0617/P05/2003/24
文摘AIM: To evaluate the reproducibility of a modified 13^C breath test-based measurement of solid phase gastric emptying (GE) within the frames of a simple-repeated measure study protocol. METHODS: Twelve healthy subjects (6 females and 6 males, mean age 24.9+0.7 years) were recruited to undergo three identical GE examinations. In six subjects the first two examinations were performed 2 d apart, and the third session was carried out at a median interval of 19.5 d (range 18 - 20 d) from the second one. In another six subjects the first two measurements were taken 20 d apart (median, range: 17-23 d), whereas the third session took place 2 d after the second one. Probes of expiratory air collected before and during six hours after intake of a solid meal (378 kcal) labelled with 75 μL (68 mg) 13^C-octanoic acid, were measured for 13^CO2 enrichment with the nondispersive isotopeselective infrared spectrometry NDIRS apparatus. RESULTS: Taking coefficients of variation for paired examinations into account, the short-term reproducibility of the GE measurement was slightly but not significantly better than the medium-term one: 7.7% and 11.2% for the lag phase (T-Lag), 7.3% and 10.9% for the gastric half emptying time (T1/2). The least differences in GE parameters detectable at P= 0.05 level in the 12 paired examinations were 9.6 and 15.6 min for T-Lag, 11.6 and 19.7 min for T1/2 by a two-day or two to three-week time gap, respectively CONCLUSION: The low-cost modification of the breath test involving a lower dose of 13^C-octanoic acid and NDIRS, renders good short- and medium-term reproducibility, as well as sensitivity of the measurement of gastric emptying of solids.
文摘In recent years, since thousands of new chemicals have been produced and put into the environment, it is important for us to screen the chemicals which have potential toxicity. So QSAR (quantitative structure-activity relationship) has been widely used.