Attenuating the noises plays an essential role in the image processing. Almost all the traditional median filters concern the removal of impulse noise having a single layer, whose noise gray level value is constant. I...Attenuating the noises plays an essential role in the image processing. Almost all the traditional median filters concern the removal of impulse noise having a single layer, whose noise gray level value is constant. In this paper, a new adaptive median filter is proposed to handle those images corrupted not only by single layer noise. The adaptive threshold median filter (ATMF) has been developed by combining the adaptive median filter (AMF) and two dynamic thresholds. Because of the dynamic threshold being used, the ATMF is able to balance the removal of the multiple-impulse noise and the quality of image. Comparison of the proposed method with traditional median filters is provided. Some visual examples are given to demonstrate the performance of the proposed filter.展开更多
More and more applications of ZnO arrester in electrical system experienced more problems.One thing,that is still under some investigation,is the effect of multiple lightning strike to the performance of ZnO arrester....More and more applications of ZnO arrester in electrical system experienced more problems.One thing,that is still under some investigation,is the effect of multiple lightning strike to the performance of ZnO arrester.As we know,the design of ZnO arrester for transmission system and for distribution system differs in the point of view of the number of ZnO blocks.Transmission system,due to its higher nominal voltage than distribution system,has more numbers of ZnO blocks inside an arrester tube.In term of the current rating of an arrester,it is found that there is some different value of the current rating.The current rating of an arrester installed closer to electrical substation is higher than that of some further away from the substation.To the respond of a lightning impulse strike,the arrester will let a high value of impulse current flowing.It tends to heat the ZnO material of the arrester.If the number of impulse strike is quite high then it may give the effect to the change of the arrester performance.This condition will endanger the equipment that is protected by the arrester from lightning strikes.During this research,the scope of work is limited to making an impulse current generator toward to one having 8/20 μs wave-shape.This kind of impulse current wave-shape is the one that is used for studying the performance of ZnO block.The effect of the inductance and capacitance of the impulse current generator were also studied.A 10 fused cut out was blown by an impulse having 10321 A of 17.8/37.8 μs.A ZnO arrester block brokendown/allowed large value of current :10982 A flowing under the voltage of 10.5展开更多
A lightning arrester is used for electrical equipment protection against damage due to lightning strikes.One example of protected electrical equipment is electrical power transformer.If there is no lightning arrester ...A lightning arrester is used for electrical equipment protection against damage due to lightning strikes.One example of protected electrical equipment is electrical power transformer.If there is no lightning arrester installed to the transformer,when a lightning strike happens,it may receive a very high lightning overvoltage,which is certainly resulted in the transformer damage at its insulation.Usually,a lightning arrester specification data attached to a lightning arrester contains the rating data of the lightning arrester current and voltage.In the use of lightning arrester,the possibility of receiving multiple lightning strikes is not taken into account sometimes.In fact,in some places,the number of multiple strikes in short duration is quiet high in number.This condition makes the lightning arrester being stroked by multiple lightning strikes.Therefore,it may change the lightning arrester's properties,and then the arrester may not be able to provide good electrical equipment protection against lightning strike anymore.This condition will result in great loss to electrical companies and electrical consumers.Therefore,this research studied the effect of applying multiple lightning strikes to ZnO lightning arrester block.Every time a group of lightning impulse current is applied to the ZnO lightning arrester block,it is followed by the measuring of its 50 Hz voltage and current characteristic. The changing in the ZnO lightning arrester block 50 Hz characteristic then can be analyzed.It was found that by applying more numbers of lightning strikes which made the arrester becoming worse,even though,actually,the lightning impulse peak current was still under the rating of the lightning arrester current.In this case for a 5 kA,24 kV lightning arrester,even though the lightning impulse peak current flowing through the ZnO lightning arrester block was still 2500 A,the lightning arrester ZnO block had already been damaged.Having been damaged,an alternating current flowing through the damaged ZnO block was about 10000 t展开更多
文摘Attenuating the noises plays an essential role in the image processing. Almost all the traditional median filters concern the removal of impulse noise having a single layer, whose noise gray level value is constant. In this paper, a new adaptive median filter is proposed to handle those images corrupted not only by single layer noise. The adaptive threshold median filter (ATMF) has been developed by combining the adaptive median filter (AMF) and two dynamic thresholds. Because of the dynamic threshold being used, the ATMF is able to balance the removal of the multiple-impulse noise and the quality of image. Comparison of the proposed method with traditional median filters is provided. Some visual examples are given to demonstrate the performance of the proposed filter.
文摘More and more applications of ZnO arrester in electrical system experienced more problems.One thing,that is still under some investigation,is the effect of multiple lightning strike to the performance of ZnO arrester.As we know,the design of ZnO arrester for transmission system and for distribution system differs in the point of view of the number of ZnO blocks.Transmission system,due to its higher nominal voltage than distribution system,has more numbers of ZnO blocks inside an arrester tube.In term of the current rating of an arrester,it is found that there is some different value of the current rating.The current rating of an arrester installed closer to electrical substation is higher than that of some further away from the substation.To the respond of a lightning impulse strike,the arrester will let a high value of impulse current flowing.It tends to heat the ZnO material of the arrester.If the number of impulse strike is quite high then it may give the effect to the change of the arrester performance.This condition will endanger the equipment that is protected by the arrester from lightning strikes.During this research,the scope of work is limited to making an impulse current generator toward to one having 8/20 μs wave-shape.This kind of impulse current wave-shape is the one that is used for studying the performance of ZnO block.The effect of the inductance and capacitance of the impulse current generator were also studied.A 10 fused cut out was blown by an impulse having 10321 A of 17.8/37.8 μs.A ZnO arrester block brokendown/allowed large value of current :10982 A flowing under the voltage of 10.5
文摘A lightning arrester is used for electrical equipment protection against damage due to lightning strikes.One example of protected electrical equipment is electrical power transformer.If there is no lightning arrester installed to the transformer,when a lightning strike happens,it may receive a very high lightning overvoltage,which is certainly resulted in the transformer damage at its insulation.Usually,a lightning arrester specification data attached to a lightning arrester contains the rating data of the lightning arrester current and voltage.In the use of lightning arrester,the possibility of receiving multiple lightning strikes is not taken into account sometimes.In fact,in some places,the number of multiple strikes in short duration is quiet high in number.This condition makes the lightning arrester being stroked by multiple lightning strikes.Therefore,it may change the lightning arrester's properties,and then the arrester may not be able to provide good electrical equipment protection against lightning strike anymore.This condition will result in great loss to electrical companies and electrical consumers.Therefore,this research studied the effect of applying multiple lightning strikes to ZnO lightning arrester block.Every time a group of lightning impulse current is applied to the ZnO lightning arrester block,it is followed by the measuring of its 50 Hz voltage and current characteristic. The changing in the ZnO lightning arrester block 50 Hz characteristic then can be analyzed.It was found that by applying more numbers of lightning strikes which made the arrester becoming worse,even though,actually,the lightning impulse peak current was still under the rating of the lightning arrester current.In this case for a 5 kA,24 kV lightning arrester,even though the lightning impulse peak current flowing through the ZnO lightning arrester block was still 2500 A,the lightning arrester ZnO block had already been damaged.Having been damaged,an alternating current flowing through the damaged ZnO block was about 10000 t