高层建筑无水箱直连供暖系统探讨 被引量:13
1
作者 刘梦真 《暖通空调》 北大核心 1997年第4期26-29,68,共5页
针对高层建筑双水箱分层供暖系统,提出了一种旨在取消双水箱的无水箱系统。
关键词 热网 连接 水箱 静水压力 高层建筑 供暖系统
下载PDF
A Laboratory Model for the Flow in Urban Street Canyons Induced by Bottom Heating 被引量:5
2
作者 刘辉志 梁彬 +2 位作者 朱凤荣 张伯寅 桑建国 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2003年第4期554-564,共11页
Water tank experiments are carried out to investigate the convection flow induced by bottom heating and the effects of the ambient wind on the flow in non-symmetrical urban street canyons based on the PIV (Particle Im... Water tank experiments are carried out to investigate the convection flow induced by bottom heating and the effects of the ambient wind on the flow in non-symmetrical urban street canyons based on the PIV (Particle Image Visualization) technique. Fluid experiments show that with calm ambient wind, the flows in the street canyon are completely driven by thermal force, and the convection can reach the upper atmosphere of the street canyon. Horizontal and vertical motions also appear above the roofs of the buildings. These are the conditions which favor the exchange of momentum and air mass between the street canyon and its environment. More than two vortices are induced by the convection, and the complex circulation pattern will vary with time in a wider street canyon. However, in a narrow street canyon, just one vortex appears. With a light ambient wind, the bottom heating and the associated convection result in just one main vortex. As the ambient wind speed increases, the vortex becomes more organized and its center shifts closer to the leeward building. 展开更多
关键词 flow in non-symmetrical urban street canyons bottom heating water tank
下载PDF
水箱水温对CO_2热泵热水器性能影响的实验研究 被引量:7
3
作者 吕静 任莹莹 +2 位作者 杨杰 豆君君 胡特特 《制冷学报》 CAS CSCD 北大核心 2012年第6期73-78,共6页
通过实验对比研究了循环加热和一次加热热水时,水箱水温对CO2热泵热水器性能的影响。循环加热工况时,随着水温的升高,压缩机的进、排气压力逐渐升高,功耗增加;气体冷却器的CO2进、出口温度升高,内侧CO2和外侧水的温差逐渐减小,换热量减... 通过实验对比研究了循环加热和一次加热热水时,水箱水温对CO2热泵热水器性能的影响。循环加热工况时,随着水温的升高,压缩机的进、排气压力逐渐升高,功耗增加;气体冷却器的CO2进、出口温度升高,内侧CO2和外侧水的温差逐渐减小,换热量减小;CO2热泵系统的COP下降。一次加热工况时,进水温度一定,系统的各项运行参数稳定,COP基本保持不变。以水温度17℃为例,系统COP在3.5左右,远远高于循环加热的COP。实验结果表明水箱水温对系统的性能有一定影响。根据实验结果提出了水箱结构改进方案,使气冷器入口水温稳定在较低水平,可有效提高系统的性能。 展开更多
关键词 热工学 CO2热泵热水器 循环加热 一次加热 水箱水温 COP
下载PDF
高校宿舍太阳能-空气源热泵复合热水系统设计与应用探讨
4
作者 林小辉 张骞 +1 位作者 张栋喆 燕博 《山西建筑》 2024年第13期151-154,198,共5页
在当前积极倡导节能减排的政策要求下,可再生能源利用逐渐普及。以西安建筑科技大学学生宿舍太阳能-空气源热泵复合热水系统为例,阐述了复合热水系统的构成、工作原理,对太阳能集热系统、空气源热泵换热系统、热水供水系统等进行了设计... 在当前积极倡导节能减排的政策要求下,可再生能源利用逐渐普及。以西安建筑科技大学学生宿舍太阳能-空气源热泵复合热水系统为例,阐述了复合热水系统的构成、工作原理,对太阳能集热系统、空气源热泵换热系统、热水供水系统等进行了设计计算,给出了集热器、热泵机组、集热水箱、供热水箱等主要设备的选型结果,提出了系统运行控制方案,并结合实际运行工况下的热性能数据,计算得到系统在不同季节的太阳能保证率、热泵能效比COP值,表明系统具有极大的节能性。 展开更多
关键词 太阳能 空气源热泵 集热水箱 供热水箱 运行控制 节能效益
下载PDF
往复加热型双水箱空气源热泵热水器试验研究 被引量:5
5
作者 张后雷 刘心志 +1 位作者 陈士发 熊荣辉 《流体机械》 CSCD 北大核心 2010年第1期61-66,71,共7页
介绍了新型往复流动加热双水箱热泵热水器的组成与工作过程,研制了试验系统,测量了系统的基本性能。试验结果表明新系统在原理上是可行的。在相同加热时间内,该系统比恒温加热型加热水量提高29%,性能系数提高19%;在相同加热水量条件下,... 介绍了新型往复流动加热双水箱热泵热水器的组成与工作过程,研制了试验系统,测量了系统的基本性能。试验结果表明新系统在原理上是可行的。在相同加热时间内,该系统比恒温加热型加热水量提高29%,性能系数提高19%;在相同加热水量条件下,该系统与常规变温加热型的性能系数和加热时间基本相同,但储热性能优于后者,说明水箱内部采用的浮子卷套结构减少了冷热水混合不可逆损失。 展开更多
关键词 热泵热水器 往复流动加热 水箱 性能系数
下载PDF
基于TRNSYS的岩土热响应测试及影响因素分析 被引量:4
6
作者 蔡颖玲 张华 +1 位作者 徐辉 陈帅 《暖通空调》 北大核心 2016年第9期135-140,共6页
针对实际工程中影响热响应测试的诸多因素,建立了基于地埋管储热模型的瞬时模型,模拟分析了加热功率、钻孔直径、水箱容积及回填材料对岩土热物性参数测试结果的影响。通过对同一口测试井两次不同功率、测试时长的实测,验证了该模型的... 针对实际工程中影响热响应测试的诸多因素,建立了基于地埋管储热模型的瞬时模型,模拟分析了加热功率、钻孔直径、水箱容积及回填材料对岩土热物性参数测试结果的影响。通过对同一口测试井两次不同功率、测试时长的实测,验证了该模型的准确性。研究结果表明:在设定不同的加热功率下,岩土导热系数和钻孔内传热热阻的测试结果分别相差4.94%和0.32%,而每延米换热量测试结果相差24.99%,同时验证了50 h为热响应测试的最小时长;热响应测试仪的水箱容积对导热系数的影响较小,仅影响了加热流体达到稳定状态的时间;当钻孔直径为110,130,150 mm时,随着回填材料导热系数的增大,岩土导热系数的变化率逐渐减小,整体增幅均在0.09 W/(m·K)内,表明回填材料对热响应测试影响较小。 展开更多
关键词 热响应测试 TRNSYS 加热功率 水箱容积 钻孔直径 回填材料 测试时长
下载PDF
太阳能季节蓄热供暖系统蓄热水箱的研究与模拟计算 被引量:4
7
作者 张广宇 曹颖 +4 位作者 王岩 李锐 付波 朱涛 索源志 《暖通空调》 2019年第3期91-96,共6页
建立了太阳能季节蓄热供暖系统的数学模型,分析了该系统的能量平衡关系。以水为介质蓄热,设置季节蓄热地下水箱,对季节蓄热水箱进行了模拟计算,分析了蓄热水箱外保温层厚度与散热量及散热率的关系、水箱体积与散热损失及散热率的关系。... 建立了太阳能季节蓄热供暖系统的数学模型,分析了该系统的能量平衡关系。以水为介质蓄热,设置季节蓄热地下水箱,对季节蓄热水箱进行了模拟计算,分析了蓄热水箱外保温层厚度与散热量及散热率的关系、水箱体积与散热损失及散热率的关系。得到保证较低散热率和成本可接受的蓄热水箱参数范围为:保温层厚度200~300 mm,水箱体积500~2 000 m^3。 展开更多
关键词 太阳能 季节蓄热 蓄热水箱 供暖系统 保温层厚度 散热率 水箱体积
下载PDF
空调热水一体机制冷兼制热水模式运行控制策略的研究 被引量:3
8
作者 江乐新 钟杰 《制冷与空调》 2011年第5期47-49,71,共4页
对空调热水一体机制冷兼制热水模式主要采用的2种运行方式进行分析,综合这2种运行方式各自的优缺点,通过理论分析,以综合能效比为切入点,提出一种基于水箱温度为控制变量的运行方式,并通过实验分析确定该运行方式下控制变量的最佳值,同... 对空调热水一体机制冷兼制热水模式主要采用的2种运行方式进行分析,综合这2种运行方式各自的优缺点,通过理论分析,以综合能效比为切入点,提出一种基于水箱温度为控制变量的运行方式,并通过实验分析确定该运行方式下控制变量的最佳值,同时进行实验验证。 展开更多
关键词 空调热水一体机 制冷兼制热水 能效比 水箱温度 控制
下载PDF
地表非均匀加热条件下边界层湍流特征的实验研究 被引量:2
9
作者 李自鑫 孙鉴泞 +1 位作者 袁仁民 罗涛 《南京大学学报(自然科学版)》 CAS CSCD 北大核心 2008年第6期575-582,共8页
在下垫面非均匀加热条件下进行对流边界层的水槽模拟实验,并与下垫面均匀加热条件下的情形对比,研究地表热力非均匀性对边界层湍流特征的影响.结果表明,地表的非均匀加热使得混合层湍流的组织性得到加强,湍流涡旋结构的空间分布比... 在下垫面非均匀加热条件下进行对流边界层的水槽模拟实验,并与下垫面均匀加热条件下的情形对比,研究地表热力非均匀性对边界层湍流特征的影响.结果表明,地表的非均匀加热使得混合层湍流的组织性得到加强,湍流涡旋结构的空间分布比较稳定,湍流强度也有明显的增强.进一步分析表明,对流边界层的发展受到下垫面热力非均匀尺度的影响,在对流边界层的发展过程中,当边界层高度为下垫面非均匀尺度的1.3~1.4倍时,夹卷速度(即边界层高度的抬升速度)最小. 展开更多
关键词 下垫面非均匀加热 非均匀尺度 对流边界层 水槽实验 湍流特征
下载PDF
相变材料应用于太阳能供暖系统的可行性分析 被引量:2
10
作者 方桂花 刘殿贺 +1 位作者 虞启辉 谭心 《机械设计与制造》 北大核心 2021年第10期198-201,共4页
搭建太阳能供暖实验平台,以太阳能集热器作为系统集热组件,水箱作为蓄热组件,风机盘管作为散热末端;建立系统的数学仿真模型并通过实验验证其正确性;目前太阳能供暖应用广泛,但其依然存在温度波动大、太阳能利用率低、浪费能源等问题。... 搭建太阳能供暖实验平台,以太阳能集热器作为系统集热组件,水箱作为蓄热组件,风机盘管作为散热末端;建立系统的数学仿真模型并通过实验验证其正确性;目前太阳能供暖应用广泛,但其依然存在温度波动大、太阳能利用率低、浪费能源等问题。针对上述问题,这里在传统太阳能供暖数学模型的基础上加入相变材料模块并模拟仿真,分析研究相变材料的加入对传统太阳能供暖系统的热影响,从而验证在太阳能供暖系统中加入相变材料的可行性,为工程实际提供参考依据。 展开更多
关键词 太阳能供暖 集热器 水箱 风机盘管 相变材料 数学模型
下载PDF
Water-Tank Experiment on the Thermal Circulation Induced by the Bottom Heating in an Asymmetric Valley 被引量:1
11
作者 刘辉志 梁彬 +2 位作者 朱凤荣 张伯寅 桑建国 《Advances in Atmospheric Sciences》 SCIE CAS CSCD 2004年第4期536-546,共11页
Water tank experiments were carried out to investigate the thermal convection due to the bottom heating in an asymmetrical valley under neutral and stably stratified approach flows with the Particle Image Velometry (P... Water tank experiments were carried out to investigate the thermal convection due to the bottom heating in an asymmetrical valley under neutral and stably stratified approach flows with the Particle Image Velometry (PIV) visualization technique. In the neutral stratification approach flow, the ascending draft induced by bottom heating is mainly located in the center of the valley in calm ambient wind. However, with ambient wind flow, the thermal convection is shifted leeward, and the descending draft is located on the leeward side of the valley, while the ascending draft is located on the windward side. The descending draft is minorly turbulent and organized, while the ascending draft is highly turbulent. With the increase of the towing speed, the descending and ascending drafts induced by the mechanical elevation begin to play a more dominant role in the valley flow, while the role of the thermal convection in the valley airflow becomes limited. In the stable stratification approach flow, the thermal convection is limited by the stable stratification and no distinct circulation is formed in calm ambient wind. With ambient wind, agravity wave appears in the upper layer in the valley. With the increase of the ambient wind speed, a gravity wave plays an important role in the valley flow, and the location and intensity of the thermal convection are also modulated by the gravity internal waves. The thermal convection has difficulty penetrating the upper stable layer. Its exchange is limited between the air in the upper layer and that in the lower layer in the valley, and it is adverse to the diffusion of pollutants in the valley. 展开更多
关键词 thermal convection in a valley water tank experiment bottom heating
下载PDF
供暖沐浴集成装置的供热能力及其与燃气热水器的适配性研究
12
作者 顾玉强 鲁信辉 《日用电器》 2022年第5期34-38,共5页
本文分析了供暖沐浴集成装置供暖能力的主要影响因素及该装置用于燃气热水器供暖的主要矛盾。研究结果表明,进水温度对供暖功率有决定性的影响。当进水温度一定时,进水量的变化对供暖功率的影响较弱;恒温混水阀可以有效的解决高温水供... 本文分析了供暖沐浴集成装置供暖能力的主要影响因素及该装置用于燃气热水器供暖的主要矛盾。研究结果表明,进水温度对供暖功率有决定性的影响。当进水温度一定时,进水量的变化对供暖功率的影响较弱;恒温混水阀可以有效的解决高温水供暖与低温水洗浴之间的矛盾,保证高的供暖功率并防止烫伤;在循环管路内加入水罐可以一定程度的改善低散热能力下的燃烧器频繁启停问题。该研究结果为燃气热水器用于供暖研究提供了一定的指导。 展开更多
关键词 供暖 燃气热水器 影响因素 恒温混水阀 水罐
下载PDF
对室内热水采暖系统开式直接连接的探讨
13
作者 王德林 《山东建筑大学学报》 1992年第3期10-14,共5页
论述了高层建筑位于多层建筑区供热外网供热范围内时,室内采暖系统如何与外网连接的问题,并通过对传统的和目前非传统的连接方式的技术分析,提出了一种新型连接方式——开式直接连接。该连接方式投资少,可靠度高,不影响建筑的平、立面布... 论述了高层建筑位于多层建筑区供热外网供热范围内时,室内采暖系统如何与外网连接的问题,并通过对传统的和目前非传统的连接方式的技术分析,提出了一种新型连接方式——开式直接连接。该连接方式投资少,可靠度高,不影响建筑的平、立面布置,并通过工程实例提供了合理的选择图示。 展开更多
关键词 热水采暖 开式直接连接 中空水膜旋流器 双水箱系统
下载PDF
开式膨胀水箱热水供暖系统膨胀管管径确定探讨
14
作者 黄明智 《河北建筑工程学院学报》 CAS 1998年第1期75-78,共4页
本文通过对一工程实例水力计算和运行效果分析,指出在使用采暖通风标准图集(T905-10和91SB-48)设计系统膨胀水箱时,膨胀管管径的确定一定要通过水力计算确定,而不能完全照搬标准图设计。
关键词 供暖系统 膨胀水箱 水力计算 标准图集
下载PDF
铁合金矿热炉烟气余热发电系统设计优化
15
作者 李涛 沈福州 《铁合金》 2018年第4期40-42,共3页
随着国家对环保要求的日益提高,矿热炉余热发电技术已经在铁合金企业中得到了广泛的应用,文章通过对矿热炉烟气余热发电热力系统及烟气系统进行优化设计的介绍,对矿热炉烟气余热发电系统设计优化进行了总结。
关键词 矿热炉 烟气 受热面 真空度 射水箱
下载PDF
西安某粘接材料厂室内供暖、热水系统的设计
16
作者 雒新峰 雒小坤 《西安航空学院学报》 2014年第5期52-54,共3页
基于厂方对供热系统的要求,根据供热建筑物、机房和可利用设施的实际情况,采用一台换热器,通过阀门的切换,实现了供暖和供热水的分段运行。将蒸汽发生器的进水与系统补水有机地整合为一个系统,有效地解决了机房面积过小的实际困难。利... 基于厂方对供热系统的要求,根据供热建筑物、机房和可利用设施的实际情况,采用一台换热器,通过阀门的切换,实现了供暖和供热水的分段运行。将蒸汽发生器的进水与系统补水有机地整合为一个系统,有效地解决了机房面积过小的实际困难。利用自来水的压力和热水箱与浴室的高差解决了热水供应的实际问题。 展开更多
关键词 供暖 切换阀门 水箱 补水
下载PDF
太阳能地面采暖系统蓄热水箱容积分析 被引量:25
17
作者 刘艳峰 王登甲 《太阳能学报》 EI CAS CSCD 北大核心 2009年第12期1636-1639,共4页
通过分析太阳能采暖系统所需蓄热量与建筑热负荷、太阳能集热量日变化规律之间的关系,得出太阳能采暖系统所需蓄热水箱容积的理论算式。根据拉萨、银川、西宁、西安等地的太阳辐射强度及建筑热负荷的日变化规律,模拟得出系统所需蓄热量... 通过分析太阳能采暖系统所需蓄热量与建筑热负荷、太阳能集热量日变化规律之间的关系,得出太阳能采暖系统所需蓄热水箱容积的理论算式。根据拉萨、银川、西宁、西安等地的太阳辐射强度及建筑热负荷的日变化规律,模拟得出系统所需蓄热量变化规律;并对各种蓄热温差下对应的蓄热水箱容积进行了模拟分析,结果表明:太阳能采暖系统所需蓄热量随太阳集热器的集热量与建筑热负荷之间的差值增大而增加;蓄热水箱容积随蓄热温差增大而减小,当蓄热水温达到80℃时,在各种地面采暖系统取水温度下,单位集热器面积所需蓄热水箱容积趋于相等。 展开更多
关键词 太阳能采暖 蓄热水箱 热负荷 集热量 蓄热温度
下载PDF
家用直膨式太阳能热泵热水系统试验研究 被引量:7
18
作者 单宝琦 宣岭柱 +1 位作者 高建华 王强 《制冷与空调》 2020年第12期42-46,共5页
搭建家用直膨式太阳能热泵热水系统试验台,测试分析太阳辐照度、水箱设定温度、集热蒸发器面积等对系统性能的影响.研究发现:在太阳辐照度由780 W/m^2提高到900 W/m^2时,系统平均COP可提高8%左右;该系统相比于同工况下常规空气源热泵热... 搭建家用直膨式太阳能热泵热水系统试验台,测试分析太阳辐照度、水箱设定温度、集热蒸发器面积等对系统性能的影响.研究发现:在太阳辐照度由780 W/m^2提高到900 W/m^2时,系统平均COP可提高8%左右;该系统相比于同工况下常规空气源热泵热水系统平均COP提高33.2%左右;水箱设定温度每提高5℃,系统平均COP降低12%左右,建议控制水箱温度在50~55℃;综合考虑系统经济性、加热时间及系统性能,建议将采用容积为150L水箱的直膨式太阳能热泵热水系统的集热蒸发器面积控制在2.0~2.6m^2. 展开更多
关键词 家用直膨式太阳能热泵热水系统 COP 辐照度 水箱温度 集热蒸发器面积
下载PDF
太阳日辐照量对太阳能热水系统热性能检测影响研究 被引量:6
19
作者 田玉兰 朱坚 李超 《中国测试》 CAS 北大核心 2015年第5期107-111,共5页
针对太阳能热水系统热性能评价规范中对太阳辐照量要求差异较大,影响实际操作的问题,开展太阳辐照量对太阳能热水系统热性能测试的影响规律研究。该文进行86 d太阳日辐照量监测和27 d对不同日辐照量下平板太阳能热水系统热性能的短期测... 针对太阳能热水系统热性能评价规范中对太阳辐照量要求差异较大,影响实际操作的问题,开展太阳辐照量对太阳能热水系统热性能测试的影响规律研究。该文进行86 d太阳日辐照量监测和27 d对不同日辐照量下平板太阳能热水系统热性能的短期测试研究。结果显示:南京市满足测试规范要求的日辐照量天气较少,在5~10月约占总天数的28%;随着日辐照量的升高,水箱的温升增加,当日辐照量较大时,贮水箱温升与日辐照量的线性关系不明显;平板太阳能热水系统热性能评定指标系统温升性能Δt17与太阳日辐照量无关,由太阳能热水系统本身性能决定。对太阳能热水系统热性能检测的日辐照量要求可适当放宽,其标准需开展系统研究;太阳能热水器热水系统的日平均热效率,可作为评定指标之一。 展开更多
关键词 太阳能热水系统 太阳日辐照量 热性能检测 水箱温升 日平均热效率
下载PDF
西藏地区太阳能直接供暖系统的设计 被引量:3
20
作者 王宏卯 郑宗和 +1 位作者 高金水 马永涛 《煤气与热力》 2007年第1期67-68,共2页
结合拉萨市西藏科技厅太阳能供暖示范工程,对太阳能直接供暖系统中太阳能集热器、集热器侧传热介质、蓄热方式、蓄热水箱、散热设备、控制系统的设计进行了研究。
关键词 太阳能直接供暖系统 集热器 蓄热水箱
下载PDF