The oil film thickness of oil hydrostatic guide with constant pressure supply based on capillary restrictor is greatly affected by load, and this kind of hydrostatic guide is usually applied to the machine tools with ...The oil film thickness of oil hydrostatic guide with constant pressure supply based on capillary restrictor is greatly affected by load, and this kind of hydrostatic guide is usually applied to the machine tools with moderate load. The static and dynamic characteristics of the guide have been studied by using some theoretical, numerical and experimental approaches, and some methods and measures have been proposed to improve its performances. The hydrostatic guide based on progressive mengen(PM) flow controller is especially suitable for the heavy numerical control(NC) machine tools. However, few literatures about the research on the static and dynamic characteristics of the hydrostatic guides based on PM flow controller are reported. In this paper, the formulae are derived for analyzing the static and dynamic characteristics of hydrostatic guides with rectangle pockets and PM flow controller according to the theory of hydrostatic bearing. On the basis of the analysis of hydrostatic bearing with circular pocket, some equations are derived for solving the static pressure, volume pressure and squeezing pressure which influence the dynamic characteristics of hydrostatic guides with rectangle pocket. The function and the influencing factors of three pressures are clarified. The formulae of amplitude-frequency characteristics and dynamic stiffness of the hydrostatic guide system are derived. With the help of software MATLAB, programs are coded with C++ language to simulate numerically the static and dynamic characteristics of the hydrostatic guide based on PM flow controller. The simulation results indicate that the sensitive oil volume between the outlet of the PM flow controller and the guide pocket has the greatest influence on the characteristics of the guide, and it should be reduced as small as possible when the field working condition is met. Choosing the oil with a greater viscosity is also helpful in improving the dynamic performance of hydrostatic guides. The research work has instructing signific展开更多
The present work proposed a new method for the modeling by the finite element method of the acoustic propagation problems in infinite axisymmetric cylindrical guides lined with locally reacting absorbent materials wit...The present work proposed a new method for the modeling by the finite element method of the acoustic propagation problems in infinite axisymmetric cylindrical guides lined with locally reacting absorbent materials without flow. The method deals with the development of an efficient transparent boundary condition based on DtN operators. The method developed in this study is successfully applied to a straight axisymmetric lined guide by imposing a mode on one of the artificial boundaries of the truncated guide. The results are in good agreement with analytical solutions. Applying the method for a non-uniform axisymmetric lined guide which is a complex case, proved its effectiveness and the results compared to those of PML layers are in very good agreement.展开更多
AIM: To present the radiological results of total knee arthroplasty(TKA) with use of patient specific matched guides(PSG) from different manufacturer in patients suffering from severe osteoarthritis of the knee joint....AIM: To present the radiological results of total knee arthroplasty(TKA) with use of patient specific matched guides(PSG) from different manufacturer in patients suffering from severe osteoarthritis of the knee joint.METHODS: This study describes the results of 57 knees operated with 4 different PSG systems and a group operated with conventional instrumentation(n = 60) by a single surgeon. The PSG systems were compared with each other and subdivided into cut- and pin PSG. The biomechanical axis [hip-knee-ankle angle(HKA)], varus/valgus of the femur [frontal femoral component(FFC)] and tibia(frontal tibial component) component, flexion/extension of the femur [flexion/extension of the femur component(LFC)] and posterior slope of the tibia [lateral tibial component(LTC)] component were evaluated on long-leg standing and lateral X-rays. A percentage of > 3° deviation was seen as an outlier. RESULTS: The inter class correlation coefficient(ICC) revealed that radiographic measurements between both assessors were reliable(ICC > 0.8). Fisher exact test was used to test differences of proportions. The percentage of outliers of the HKA-axis was comparable between both the PSG and conventional groups(12.28% vs 18.33%, P < 0.424) and the cut- and pin PSG groups(14.3% vs 10.3%, P < 1.00). The percentage of outliers of the FFC(0% vs 18.33%, P < 0.000), LFC(15.78% vs 58.33%, P < 0.000) and LTC(15.78% vs 41.67%, P < 0.033) were significant different in favour of the PSGgroup. There were no significant differences regarding the outliers between the individual PSG systems and the PSG group subdivided into cut- and pin PSG.CONCLUSION: PSG for TKA show significant less outliers compared to the conventional technique. These single surgeon results suggest that PSG are ready for primetime.展开更多
Gravimetry technical guides are the scientific basis for air-sea gravimetry. However, the existing technical guides in China are behind the application requirements. This study analyzed the most important indicators o...Gravimetry technical guides are the scientific basis for air-sea gravimetry. However, the existing technical guides in China are behind the application requirements. This study analyzed the most important indicators of air-sea gravimetry, including the density of survey lines, gravimetry accuracy and space resolution, stability and reliability of the air-sea gravimeter, and proposed a gravimetry accuracy assessment system consisting of gravity RMS of error, systematic error and mean error, and an assessment system for the gravimeter stability consisting of the relative accuracy of the scale value, monthly zero-drift, RMS of the monthly nonlinear zero-drift variation and the threshold of the monthly nonlinear zero-drift variation. The mathematic models for the measurement point determination in shipborne gravimetry, E tv s correction for airborne gravimetry, platform tilt correction and evaluation air-sea gravimetry were also analyzed and modified. This work will provide technology support for the composition of the military-civil air-sea gravimetry technical guides.展开更多
BACKGROUND Acetabular component positioning in total hip arthroplasty(THA)is of key importance to ensure satisfactory post-operative outcomes and to minimize the risk of complications.The majority of acetabular compon...BACKGROUND Acetabular component positioning in total hip arthroplasty(THA)is of key importance to ensure satisfactory post-operative outcomes and to minimize the risk of complications.The majority of acetabular components are aligned freehand,without the use of navigation methods.Patient specific instruments(PSI)and three-dimensional(3D)printing of THA placement guides are increasingly used in primary THA to ensure optimal positioning.AIM To summarize the literature on 3D printing in THA and how they improve acetabular component alignment.METHODS PubMed was used to identify and access scientific studies reporting on different 3D printing methods used in THA.Eight studies with 236 hips in 228 patients were included.The studies could be divided into two main categories;3D printed models and 3D printed guides.RESULTS 3D printing in THA helped improve preoperative cup size planning and post-operative Harris hip scores between intervention and control groups(P=0.019,P=0.009).Otherwise,outcome measures were heterogeneous and thus difficult to compare.The overarching consensus between the studies is that the use of 3D guidance tools can assist in improving THA cup positioning and reduce the need for revision THA and the associated costs.CONCLUSION The implementation of 3D printing and PSI for primary THA can significantly improve the positioning accuracy of the acetabular cup component and reduce the number of complications caused by malpositioning.展开更多
Injury to peripheral nerves is often observed in the clinic and severe injuries may cause loss of motor and sensory functions.Despite extensive investigation,testing various surgical repair techniques and neurotrophic...Injury to peripheral nerves is often observed in the clinic and severe injuries may cause loss of motor and sensory functions.Despite extensive investigation,testing various surgical repair techniques and neurotrophic molecules,at present,a satisfactory method to ensuring successful recovery does not exist.For successful molecular therapy in nerve regeneration,it is essential to improve the intrinsic ability of neurons to survive and to increase the speed of axonal outgrowth.Also to induce Schwann cell phenotypical changes to prepare the local environment favorable for axonal regeneration and myelination.Therefore,any molecule that regulates gene expression of both neurons and Schwann cells could play a crucial role in peripheral nerve regeneration.Clinical and experimental studies have reported that thyroid hormones are essential for the normal development and function of the nervous system,so they could be candidates for nervous system regeneration.This review provides an overview of studies devoted to testing the effect of thyroid hormones on peripheral nerve regeneration.Also it emphasizes the importance of combining biodegradable tubes with local administration of triiodothyronine for future clinical therapy of human severe injured nerves.We highlight that the local and single administration of triiodothyronine within biodegradable nerve guide improves significantly the regeneration of severed peripheral nerves,and accelerates functional recovering.This technique provides a serious step towards future clinical application of triiodothyronine in human severe injured nerves.The possible regulatory mechanism by which triiodothyronine stimulates peripheral nerve regeneration is a rapid action on both axotomized neurons and Schwann cells.展开更多
文摘The oil film thickness of oil hydrostatic guide with constant pressure supply based on capillary restrictor is greatly affected by load, and this kind of hydrostatic guide is usually applied to the machine tools with moderate load. The static and dynamic characteristics of the guide have been studied by using some theoretical, numerical and experimental approaches, and some methods and measures have been proposed to improve its performances. The hydrostatic guide based on progressive mengen(PM) flow controller is especially suitable for the heavy numerical control(NC) machine tools. However, few literatures about the research on the static and dynamic characteristics of the hydrostatic guides based on PM flow controller are reported. In this paper, the formulae are derived for analyzing the static and dynamic characteristics of hydrostatic guides with rectangle pockets and PM flow controller according to the theory of hydrostatic bearing. On the basis of the analysis of hydrostatic bearing with circular pocket, some equations are derived for solving the static pressure, volume pressure and squeezing pressure which influence the dynamic characteristics of hydrostatic guides with rectangle pocket. The function and the influencing factors of three pressures are clarified. The formulae of amplitude-frequency characteristics and dynamic stiffness of the hydrostatic guide system are derived. With the help of software MATLAB, programs are coded with C++ language to simulate numerically the static and dynamic characteristics of the hydrostatic guide based on PM flow controller. The simulation results indicate that the sensitive oil volume between the outlet of the PM flow controller and the guide pocket has the greatest influence on the characteristics of the guide, and it should be reduced as small as possible when the field working condition is met. Choosing the oil with a greater viscosity is also helpful in improving the dynamic performance of hydrostatic guides. The research work has instructing signific
文摘The present work proposed a new method for the modeling by the finite element method of the acoustic propagation problems in infinite axisymmetric cylindrical guides lined with locally reacting absorbent materials without flow. The method deals with the development of an efficient transparent boundary condition based on DtN operators. The method developed in this study is successfully applied to a straight axisymmetric lined guide by imposing a mode on one of the artificial boundaries of the truncated guide. The results are in good agreement with analytical solutions. Applying the method for a non-uniform axisymmetric lined guide which is a complex case, proved its effectiveness and the results compared to those of PML layers are in very good agreement.
文摘AIM: To present the radiological results of total knee arthroplasty(TKA) with use of patient specific matched guides(PSG) from different manufacturer in patients suffering from severe osteoarthritis of the knee joint.METHODS: This study describes the results of 57 knees operated with 4 different PSG systems and a group operated with conventional instrumentation(n = 60) by a single surgeon. The PSG systems were compared with each other and subdivided into cut- and pin PSG. The biomechanical axis [hip-knee-ankle angle(HKA)], varus/valgus of the femur [frontal femoral component(FFC)] and tibia(frontal tibial component) component, flexion/extension of the femur [flexion/extension of the femur component(LFC)] and posterior slope of the tibia [lateral tibial component(LTC)] component were evaluated on long-leg standing and lateral X-rays. A percentage of > 3° deviation was seen as an outlier. RESULTS: The inter class correlation coefficient(ICC) revealed that radiographic measurements between both assessors were reliable(ICC > 0.8). Fisher exact test was used to test differences of proportions. The percentage of outliers of the HKA-axis was comparable between both the PSG and conventional groups(12.28% vs 18.33%, P < 0.424) and the cut- and pin PSG groups(14.3% vs 10.3%, P < 1.00). The percentage of outliers of the FFC(0% vs 18.33%, P < 0.000), LFC(15.78% vs 58.33%, P < 0.000) and LTC(15.78% vs 41.67%, P < 0.033) were significant different in favour of the PSGgroup. There were no significant differences regarding the outliers between the individual PSG systems and the PSG group subdivided into cut- and pin PSG.CONCLUSION: PSG for TKA show significant less outliers compared to the conventional technique. These single surgeon results suggest that PSG are ready for primetime.
基金The National Natural Science Foundation of China (41804011, 41706111)The National Major Development Program of China(2016YFC0303007,2016YFB0501704)+1 种基金The Great Scientific Instrument Development Project of China(2011YQ12004503)The National Basic Research Program of China(973 Program)(613219).
文摘Gravimetry technical guides are the scientific basis for air-sea gravimetry. However, the existing technical guides in China are behind the application requirements. This study analyzed the most important indicators of air-sea gravimetry, including the density of survey lines, gravimetry accuracy and space resolution, stability and reliability of the air-sea gravimeter, and proposed a gravimetry accuracy assessment system consisting of gravity RMS of error, systematic error and mean error, and an assessment system for the gravimeter stability consisting of the relative accuracy of the scale value, monthly zero-drift, RMS of the monthly nonlinear zero-drift variation and the threshold of the monthly nonlinear zero-drift variation. The mathematic models for the measurement point determination in shipborne gravimetry, E tv s correction for airborne gravimetry, platform tilt correction and evaluation air-sea gravimetry were also analyzed and modified. This work will provide technology support for the composition of the military-civil air-sea gravimetry technical guides.
文摘BACKGROUND Acetabular component positioning in total hip arthroplasty(THA)is of key importance to ensure satisfactory post-operative outcomes and to minimize the risk of complications.The majority of acetabular components are aligned freehand,without the use of navigation methods.Patient specific instruments(PSI)and three-dimensional(3D)printing of THA placement guides are increasingly used in primary THA to ensure optimal positioning.AIM To summarize the literature on 3D printing in THA and how they improve acetabular component alignment.METHODS PubMed was used to identify and access scientific studies reporting on different 3D printing methods used in THA.Eight studies with 236 hips in 228 patients were included.The studies could be divided into two main categories;3D printed models and 3D printed guides.RESULTS 3D printing in THA helped improve preoperative cup size planning and post-operative Harris hip scores between intervention and control groups(P=0.019,P=0.009).Otherwise,outcome measures were heterogeneous and thus difficult to compare.The overarching consensus between the studies is that the use of 3D guidance tools can assist in improving THA cup positioning and reduce the need for revision THA and the associated costs.CONCLUSION The implementation of 3D printing and PSI for primary THA can significantly improve the positioning accuracy of the acetabular cup component and reduce the number of complications caused by malpositioning.
基金supported by the Swiss National Science FoundationSUVA foundationNovartis foundation
文摘Injury to peripheral nerves is often observed in the clinic and severe injuries may cause loss of motor and sensory functions.Despite extensive investigation,testing various surgical repair techniques and neurotrophic molecules,at present,a satisfactory method to ensuring successful recovery does not exist.For successful molecular therapy in nerve regeneration,it is essential to improve the intrinsic ability of neurons to survive and to increase the speed of axonal outgrowth.Also to induce Schwann cell phenotypical changes to prepare the local environment favorable for axonal regeneration and myelination.Therefore,any molecule that regulates gene expression of both neurons and Schwann cells could play a crucial role in peripheral nerve regeneration.Clinical and experimental studies have reported that thyroid hormones are essential for the normal development and function of the nervous system,so they could be candidates for nervous system regeneration.This review provides an overview of studies devoted to testing the effect of thyroid hormones on peripheral nerve regeneration.Also it emphasizes the importance of combining biodegradable tubes with local administration of triiodothyronine for future clinical therapy of human severe injured nerves.We highlight that the local and single administration of triiodothyronine within biodegradable nerve guide improves significantly the regeneration of severed peripheral nerves,and accelerates functional recovering.This technique provides a serious step towards future clinical application of triiodothyronine in human severe injured nerves.The possible regulatory mechanism by which triiodothyronine stimulates peripheral nerve regeneration is a rapid action on both axotomized neurons and Schwann cells.