A promising scheme for coal-fired power plants in which biomass co-firing and carbon dioxide capture technologies are adopted and the low-temperature waste heat from the CO_(2) capture process is recycled to heat the ...A promising scheme for coal-fired power plants in which biomass co-firing and carbon dioxide capture technologies are adopted and the low-temperature waste heat from the CO_(2) capture process is recycled to heat the condensed water to achieve zero carbon emission is proposed in this paper.Based on a 660 MW supercritical coal-fired power plant,the thermal performance,emission performance,and economic performance of the proposed scheme are evaluated.In addition,a sensitivity analysis is conducted to show the effects of several key parameters on the performance of the proposed system.The results show that when the biomass mass mixing ratio is 15.40%and the CO_(2) capture rate is 90%,the CO_(2) emission of the coal-fired power plant can reach zero,indicating that the technical route proposed in this paper can indeed achieve zero carbon emission in coal-fired power plants.The net thermal efficiency decreases by 10.31%,due to the huge energy consumption of the CO_(2) capture unit.Besides,the cost of electricity(COE)and the cost of CO_(2) avoided(COA)of the proposed system are 80.37/MWhand41.63/tCO_(2),respectively.The sensitivity analysis demonstrates that with the energy consumption of the reboiler decreasing from 3.22 GJ/tCO_(2) to 2.40 GJ/tCO_(2),the efficiency penalty is reduced to 8.67%.This paper may provide reference for promoting the early realization of carbon neutrality in the power generation industry.展开更多
A part load operation by turning the burner on and off intermittently is effective for a small scale direct fired absorption chiller. The dynamic performance of the system has been investigated. The relationship betwe...A part load operation by turning the burner on and off intermittently is effective for a small scale direct fired absorption chiller. The dynamic performance of the system has been investigated. The relationship between pressure, temperature and concentration of the lithium bromide solution have been analyzed. The result obtained indicates that the pressure of the high pressure generator and the temperature of the exhausted smoke are the most sensitive parameters. It is also found that the transition time from a full load to a part load condition is quite long, and part load relative cooling capacity is almost near the intermittent running time ratio and oil consumption ratio.展开更多
Based on the activity level and technical information of coal-fired power-generating units(CFPGU)obtained in China from 2011 to 2015,we,1)analyzed the time and spatial distribution of SO_(2) and NOx emission performan...Based on the activity level and technical information of coal-fired power-generating units(CFPGU)obtained in China from 2011 to 2015,we,1)analyzed the time and spatial distribution of SO_(2) and NOx emission performance of CFPGUs in China;2)studied the impact of installed capacity,sulfur content of coal combustion,and unit operation starting time on CFPGUs’pollutant emission performance;and 3)proposed the SO_(2) and NOx emission performance standards for coal-fired power plants based on the best available control technology.Our results show that:1)the larger the capacity of a CFPGU,the higher the control level and the faster the improvement;2)the CFPGUs in the developed eastern regions had significantly lower SO_(2) and NOx emission performance values than those in other provinces due to better economic and technological development and higher environmental management levels;3)the SO_(2) and NOx emission performance of the Chinese thermal power industry was significantly affected by the single-unit capacity,coal sulfur content,and unit operation starting time;and 4)based on the achievability analysis of best available pollution control technology,we believe that the CFPGUs’SO_(2) emission performance reference values should be 0.34 g/kWh for active units in general areas,0.8 g/kWh for active units in high-sulfur coal areas,and 0.13 g/kWh for newly built units and active units in key areas.In addition,the NOx emission performance reference values should be 0.35 g/kWh for active units in general areas and 0.175 g/kWh for new units and active units in key areas.展开更多
Large size utility boilers develop rapidly in China, both their reliability and economics have reached better level. The operating situations of various existing boilers on the basis of different coals are analyzed, i...Large size utility boilers develop rapidly in China, both their reliability and economics have reached better level. The operating situations of various existing boilers on the basis of different coals are analyzed, it is held that, the notable energy imbalance of furnace exit, ever existing in the tangential firing boilers has been solved, with comparatively lower NOX emission concentration of gained. The higher NOX emission concentration and furnace slagging etc. problems existing in wall firing boilers are notable. The comprehensive analysis shows that, it is appropriate to choose lower furnace volume heat release rate and higher flame height in the type selection design of boilers, and sufficient margin should be kept in the selection of coal pulverizing mills.展开更多
Integrating solar power utilization systems with coal-fired power units, the solar aided coal-fired power generation (SACPG) shows a significant prospect for the large-scale utilization of solar energy and energy savi...Integrating solar power utilization systems with coal-fired power units, the solar aided coal-fired power generation (SACPG) shows a significant prospect for the large-scale utilization of solar energy and energy saving of thermal power units. The methods and mechanism of system integration were studied. The parabolic trough solar collectors were used to collect solar energy and the integration scheme of SACPG system was determined considering the matching of working fluid flows and energy flows. The thermodynamic characteristics of solar thermal power generation and their effects on the performance of thermal power units were studied, and based on this the integration and optimization model of system structure and parameters were built up. The integration rules and coupling mecha- nism of SACPG systems were summarized in accordance with simulation results. The economic analysis of this SACPG system showed that the solar LEC of a typical SACPG system, considering CO2 avoidance, is 0.098 $/kW·h, lower than that of SEGS, 0.14 $/kW·h.展开更多
太阳能与燃煤互补发电方式是近年来大规模太阳能热利用的发展方向之一。以槽式太阳能集热系统辅助某330MW燃煤机组替代高加回热抽汽加热给水的互补发电系统为例,对功率不变型互补发电系统的设计点热力性能及年热力性能进行了分析。结果...太阳能与燃煤互补发电方式是近年来大规模太阳能热利用的发展方向之一。以槽式太阳能集热系统辅助某330MW燃煤机组替代高加回热抽汽加热给水的互补发电系统为例,对功率不变型互补发电系统的设计点热力性能及年热力性能进行了分析。结果表明,太阳能辅助发电系统的年光电转换效率可达到20.41%,高于单纯槽式太阳能热发电方式。在此基础上,以内部收益率(internal rate of return,IRR)作为评价指标,运用技术经济的基本原理对太阳能辅助燃煤机组互补发电系统的经济性能及其主要影响因素进行了定量的分析评价,得到了太阳能上网电价、集热器造价、燃料成本等关键因素对内部收益率的影响。展开更多
基金supported by the National Natural Science Foundation of China(Grant No.51806062)the Science Fund for Creative Research Groups of the National Natural Science Foundation of China(Grant No.51821004)the Fundamental Research Funds for the Central Universities(Grant No.2020MS006).
文摘A promising scheme for coal-fired power plants in which biomass co-firing and carbon dioxide capture technologies are adopted and the low-temperature waste heat from the CO_(2) capture process is recycled to heat the condensed water to achieve zero carbon emission is proposed in this paper.Based on a 660 MW supercritical coal-fired power plant,the thermal performance,emission performance,and economic performance of the proposed scheme are evaluated.In addition,a sensitivity analysis is conducted to show the effects of several key parameters on the performance of the proposed system.The results show that when the biomass mass mixing ratio is 15.40%and the CO_(2) capture rate is 90%,the CO_(2) emission of the coal-fired power plant can reach zero,indicating that the technical route proposed in this paper can indeed achieve zero carbon emission in coal-fired power plants.The net thermal efficiency decreases by 10.31%,due to the huge energy consumption of the CO_(2) capture unit.Besides,the cost of electricity(COE)and the cost of CO_(2) avoided(COA)of the proposed system are 80.37/MWhand41.63/tCO_(2),respectively.The sensitivity analysis demonstrates that with the energy consumption of the reboiler decreasing from 3.22 GJ/tCO_(2) to 2.40 GJ/tCO_(2),the efficiency penalty is reduced to 8.67%.This paper may provide reference for promoting the early realization of carbon neutrality in the power generation industry.
文摘A part load operation by turning the burner on and off intermittently is effective for a small scale direct fired absorption chiller. The dynamic performance of the system has been investigated. The relationship between pressure, temperature and concentration of the lithium bromide solution have been analyzed. The result obtained indicates that the pressure of the high pressure generator and the temperature of the exhausted smoke are the most sensitive parameters. It is also found that the transition time from a full load to a part load condition is quite long, and part load relative cooling capacity is almost near the intermittent running time ratio and oil consumption ratio.
基金supported by the National Key Research and Development Plan(No.2016YFC0208400).
文摘Based on the activity level and technical information of coal-fired power-generating units(CFPGU)obtained in China from 2011 to 2015,we,1)analyzed the time and spatial distribution of SO_(2) and NOx emission performance of CFPGUs in China;2)studied the impact of installed capacity,sulfur content of coal combustion,and unit operation starting time on CFPGUs’pollutant emission performance;and 3)proposed the SO_(2) and NOx emission performance standards for coal-fired power plants based on the best available control technology.Our results show that:1)the larger the capacity of a CFPGU,the higher the control level and the faster the improvement;2)the CFPGUs in the developed eastern regions had significantly lower SO_(2) and NOx emission performance values than those in other provinces due to better economic and technological development and higher environmental management levels;3)the SO_(2) and NOx emission performance of the Chinese thermal power industry was significantly affected by the single-unit capacity,coal sulfur content,and unit operation starting time;and 4)based on the achievability analysis of best available pollution control technology,we believe that the CFPGUs’SO_(2) emission performance reference values should be 0.34 g/kWh for active units in general areas,0.8 g/kWh for active units in high-sulfur coal areas,and 0.13 g/kWh for newly built units and active units in key areas.In addition,the NOx emission performance reference values should be 0.35 g/kWh for active units in general areas and 0.175 g/kWh for new units and active units in key areas.
文摘Large size utility boilers develop rapidly in China, both their reliability and economics have reached better level. The operating situations of various existing boilers on the basis of different coals are analyzed, it is held that, the notable energy imbalance of furnace exit, ever existing in the tangential firing boilers has been solved, with comparatively lower NOX emission concentration of gained. The higher NOX emission concentration and furnace slagging etc. problems existing in wall firing boilers are notable. The comprehensive analysis shows that, it is appropriate to choose lower furnace volume heat release rate and higher flame height in the type selection design of boilers, and sufficient margin should be kept in the selection of coal pulverizing mills.
基金Supported by the National Natural Science Foundation of China (Grant Nos. 50776028 and 50606010) the Program for New Century Excellent Talents in University (Grant No. NCET-05-0217)
文摘Integrating solar power utilization systems with coal-fired power units, the solar aided coal-fired power generation (SACPG) shows a significant prospect for the large-scale utilization of solar energy and energy saving of thermal power units. The methods and mechanism of system integration were studied. The parabolic trough solar collectors were used to collect solar energy and the integration scheme of SACPG system was determined considering the matching of working fluid flows and energy flows. The thermodynamic characteristics of solar thermal power generation and their effects on the performance of thermal power units were studied, and based on this the integration and optimization model of system structure and parameters were built up. The integration rules and coupling mecha- nism of SACPG systems were summarized in accordance with simulation results. The economic analysis of this SACPG system showed that the solar LEC of a typical SACPG system, considering CO2 avoidance, is 0.098 $/kW·h, lower than that of SEGS, 0.14 $/kW·h.
文摘太阳能与燃煤互补发电方式是近年来大规模太阳能热利用的发展方向之一。以槽式太阳能集热系统辅助某330MW燃煤机组替代高加回热抽汽加热给水的互补发电系统为例,对功率不变型互补发电系统的设计点热力性能及年热力性能进行了分析。结果表明,太阳能辅助发电系统的年光电转换效率可达到20.41%,高于单纯槽式太阳能热发电方式。在此基础上,以内部收益率(internal rate of return,IRR)作为评价指标,运用技术经济的基本原理对太阳能辅助燃煤机组互补发电系统的经济性能及其主要影响因素进行了定量的分析评价,得到了太阳能上网电价、集热器造价、燃料成本等关键因素对内部收益率的影响。