The present paper proposes the impact of the air temperature on electricity demand as expected. It is clear that the annual maximum load is recorded versus the years starting by the year 2009 up to 2012. At present, t...The present paper proposes the impact of the air temperature on electricity demand as expected. It is clear that the annual maximum load is recorded versus the years starting by the year 2009 up to 2012. At present, the graph fitting technique is applied with some mathematical and computational tools based on the actual values of the years 2009 up to 2012 considering the lower values, the higher values and the average values of the annual maximum loads for Kingdom of Bahrain. For the three scenarios, the models are obtained by curve fitting technique. As well, the model of actual loads is obtained finally which has mostly the closest values obtained.展开更多
In Japan,in order to determine the capacity of air-conditioning equipment,designers usually use the weather database of Reference Weather Year(RWY)to obtain the design air-conditioning load by using software such as N...In Japan,in order to determine the capacity of air-conditioning equipment,designers usually use the weather database of Reference Weather Year(RWY)to obtain the design air-conditioning load by using software such as New HASP/ACLD and Building Energy Simulation Tool(BEST)that are often used in Japan.In recent years,with the global warming due to climate change,the weather database used to calculate air conditioning load also changes.Thus,in order to determine an appropriate capacity of air-conditioning equipment for energy conservation of buildings,the deviation of design air-conditioning load calculated using the weather database of RWY and Actual Weather Year(AWY)should be discussed.In this paper,New HASP/ACLD was used to calculate the building heat loads of eight major Japanese cities over 30 years(1981-2010)between RWY and AWY.The heat load at an exceedance probability of 2.5%is defined as the design air-conditioning load in this paper.Comparing the design air-conditioning load obtained from RWY and AWY,it is shown that it is not necessarily the most appropriate when using the RWY to calculate the design air-conditioning load,especially for heating load in winter.Additionally,it is also shown that the annual heating load time ratio has decreased and the annual cooling load time ratio has increased over the 30 years.展开更多
The influence of ecological technology measures on the annual sediment loads of rivers complies with the principles of statistics. In this paper, the annual sediment load of the Wuding River is taken as the dependent ...The influence of ecological technology measures on the annual sediment loads of rivers complies with the principles of statistics. In this paper, the annual sediment load of the Wuding River is taken as the dependent variable and the rainfall, rainstorms during the flood period of the Wuding River and areas of ecological technology measures are taken as the independent variables to analyze the influence of ecological technology measures on the annual sediment load of the Wuding River during the years 1956 to 2007. This research uses a stepwise regression method. The result shows that 1) the non-linear regression equation composed of three independent variables including 7–8 monthly rainfalls along the Wuding River, areas of ecological technology measures and maximum daily rainfall along the Wuding River has been calculated and set up; the correlation coefficient is R2=0.857 and the significance level is α=0.001. 2) R2=0.717 is adjusted and the regression equation reveals a change of annual sediment load exceeding 71.7% over 52 years; 3) The standardized regression coefficient for ecological technology measure area has the maximum absolute value of the three independent variables shows maximum influence on the change of annual sediment load; and 4) Because of implementing the ecological technology measures, until to year of 2007, when the 7–8 monthly rainfall and maximum daily rainfall are the maximum values in the research section, the annual sediment load is calculated as 149 million ton, which is 36% of the maximum value in the history.展开更多
文摘The present paper proposes the impact of the air temperature on electricity demand as expected. It is clear that the annual maximum load is recorded versus the years starting by the year 2009 up to 2012. At present, the graph fitting technique is applied with some mathematical and computational tools based on the actual values of the years 2009 up to 2012 considering the lower values, the higher values and the average values of the annual maximum loads for Kingdom of Bahrain. For the three scenarios, the models are obtained by curve fitting technique. As well, the model of actual loads is obtained finally which has mostly the closest values obtained.
文摘In Japan,in order to determine the capacity of air-conditioning equipment,designers usually use the weather database of Reference Weather Year(RWY)to obtain the design air-conditioning load by using software such as New HASP/ACLD and Building Energy Simulation Tool(BEST)that are often used in Japan.In recent years,with the global warming due to climate change,the weather database used to calculate air conditioning load also changes.Thus,in order to determine an appropriate capacity of air-conditioning equipment for energy conservation of buildings,the deviation of design air-conditioning load calculated using the weather database of RWY and Actual Weather Year(AWY)should be discussed.In this paper,New HASP/ACLD was used to calculate the building heat loads of eight major Japanese cities over 30 years(1981-2010)between RWY and AWY.The heat load at an exceedance probability of 2.5%is defined as the design air-conditioning load in this paper.Comparing the design air-conditioning load obtained from RWY and AWY,it is shown that it is not necessarily the most appropriate when using the RWY to calculate the design air-conditioning load,especially for heating load in winter.Additionally,it is also shown that the annual heating load time ratio has decreased and the annual cooling load time ratio has increased over the 30 years.
基金National Key Research and Development Program of China(2016YFC0503700)
文摘The influence of ecological technology measures on the annual sediment loads of rivers complies with the principles of statistics. In this paper, the annual sediment load of the Wuding River is taken as the dependent variable and the rainfall, rainstorms during the flood period of the Wuding River and areas of ecological technology measures are taken as the independent variables to analyze the influence of ecological technology measures on the annual sediment load of the Wuding River during the years 1956 to 2007. This research uses a stepwise regression method. The result shows that 1) the non-linear regression equation composed of three independent variables including 7–8 monthly rainfalls along the Wuding River, areas of ecological technology measures and maximum daily rainfall along the Wuding River has been calculated and set up; the correlation coefficient is R2=0.857 and the significance level is α=0.001. 2) R2=0.717 is adjusted and the regression equation reveals a change of annual sediment load exceeding 71.7% over 52 years; 3) The standardized regression coefficient for ecological technology measure area has the maximum absolute value of the three independent variables shows maximum influence on the change of annual sediment load; and 4) Because of implementing the ecological technology measures, until to year of 2007, when the 7–8 monthly rainfall and maximum daily rainfall are the maximum values in the research section, the annual sediment load is calculated as 149 million ton, which is 36% of the maximum value in the history.