Flexible load can optimize the load curve,which is an important means to promote renewable energy consumption.The peculiarities of electricity,heat,cooling and gas loads are analyzed in this paper,considering the fuzz...Flexible load can optimize the load curve,which is an important means to promote renewable energy consumption.The peculiarities of electricity,heat,cooling and gas loads are analyzed in this paper,considering the fuzzy degree of human perception for water temperature,and the characteristic model of hot water load is established.Considering the fuzzy degree of human perception of ambient temperature,the characteristic model of cooling load is established by using PMV and PPD index.Meanwhile,considering four combinations of cut load,translatable load,transferable load and alternative load,and considering the coupling relationship of composite parts,different response models of load are established respectively.With the minimum cost of the system,including operation and compensation costs as the objective function,the optimization scheduling model of the regional integrated energy system is established,and the Gurobi solver is used for simulation analysis to solve the optimal output and load response curve of each piece of equipment.The results show that the load curve can be optimized,the flexible regulation ability of the regional integrated energy system can be enhanced,the energy loss of the system can be reduced,and the wind power consumption ability of the system can be increased by considering the integrated demand response.展开更多
A new staggered isolated system developed from the mid-story isolated system is the new staggered story isolated system. There are not many studies on this structure currently. In this study, an 18-story new staggered...A new staggered isolated system developed from the mid-story isolated system is the new staggered story isolated system. There are not many studies on this structure currently. In this study, an 18-story new staggered story isolated system model is established using SAP2000. The dynamic nonlinear dynamic alternate method is used to analyze the structure against progressive collapse. Results show that the structure has good resistance to progressive collapse, and there is no progressive collapse under each working condition. The progressive collapse does not occur for the case of removing only one vertical structural member of the new staggered of isolated system. The side column has big influence on this isolated structures’ progressive collapse;the removal of vertical structural member of the isolation layer has less impact on the structure than the removal of the bottom vertical structural member. After the removing of the member, the internal force of the structure will be redistributed, and the axial force of the adjacent columns will change obviously, showing a trend of “near large and far small”.展开更多
基金supported by the National Natural Science Foundation of China(51577086)Jiangsu Key University Science Research Project(19KJA510012)+1 种基金Six talent peaks project in Jiangsu Province(TD-XNY004)Jiangsu Qinglan Project.
文摘Flexible load can optimize the load curve,which is an important means to promote renewable energy consumption.The peculiarities of electricity,heat,cooling and gas loads are analyzed in this paper,considering the fuzzy degree of human perception for water temperature,and the characteristic model of hot water load is established.Considering the fuzzy degree of human perception of ambient temperature,the characteristic model of cooling load is established by using PMV and PPD index.Meanwhile,considering four combinations of cut load,translatable load,transferable load and alternative load,and considering the coupling relationship of composite parts,different response models of load are established respectively.With the minimum cost of the system,including operation and compensation costs as the objective function,the optimization scheduling model of the regional integrated energy system is established,and the Gurobi solver is used for simulation analysis to solve the optimal output and load response curve of each piece of equipment.The results show that the load curve can be optimized,the flexible regulation ability of the regional integrated energy system can be enhanced,the energy loss of the system can be reduced,and the wind power consumption ability of the system can be increased by considering the integrated demand response.
文摘A new staggered isolated system developed from the mid-story isolated system is the new staggered story isolated system. There are not many studies on this structure currently. In this study, an 18-story new staggered story isolated system model is established using SAP2000. The dynamic nonlinear dynamic alternate method is used to analyze the structure against progressive collapse. Results show that the structure has good resistance to progressive collapse, and there is no progressive collapse under each working condition. The progressive collapse does not occur for the case of removing only one vertical structural member of the new staggered of isolated system. The side column has big influence on this isolated structures’ progressive collapse;the removal of vertical structural member of the isolation layer has less impact on the structure than the removal of the bottom vertical structural member. After the removing of the member, the internal force of the structure will be redistributed, and the axial force of the adjacent columns will change obviously, showing a trend of “near large and far small”.