能源危机和温室效应促进了可再生能源的利用,储能技术是解决太阳能、风能波动问题的重要手段。压缩空气储能(Compressed Air Energy Storage,CAES)技术是仅次于抽水蓄能的第二大蓄能技术。目前CAES多是通过洞穴实现,其主要缺点是对地质...能源危机和温室效应促进了可再生能源的利用,储能技术是解决太阳能、风能波动问题的重要手段。压缩空气储能(Compressed Air Energy Storage,CAES)技术是仅次于抽水蓄能的第二大蓄能技术。目前CAES多是通过洞穴实现,其主要缺点是对地质要求较高,合适的洞穴数量有限,为扩大其应用,可使用地下咸水含水层作为储层。本文介绍了CAES电站的工作原理、优缺点及各国的发展现状,并分析了利用地下咸水含水层进行压缩空气储能的可行性、优点及一些问题与技术方法,如储层内残余烃的影响、氧化与腐蚀作用、颗粒的影响及缓冲气的选择,表明含水层CAES将是拓宽CAES应用的重要途径。展开更多
In this study, the three-dimensional physical model of pleated air filtration media was simplified to porous media model, and the calculation parameters of porous media were obtained based on experimental data. The mo...In this study, the three-dimensional physical model of pleated air filtration media was simplified to porous media model, and the calculation parameters of porous media were obtained based on experimental data. The model of V-shaped pleated air filter media is constructed, the height of the media pleat is 50 mm and the pleat thickness is 4 mm, the pleat angle is 3.7°. The Hertz-Mindlin contact model was modified by Johnson Kendall Roberts (JKR) adhesion contact model. The deposition process of particles in media was simulated based on computational fluid dynamics (CFD) theory and discrete element method (DEM). Results show that the CFD–DEM coupling method can be effectively applied to the macro research of pleated air filter media. The particles will form dust layer and dendrite structure on the fiber surface, and the dust layer will affect the subsequent air flow organization, and the dendrite structure will eventually form a “particle wall”. The formation of the “particle wall” will prevent the particles from moving further in the fluid domain, which makes area of pleated angle become the “low efficiency” part about the particle deposition. Compared with area of pleated angle, the particles are concentrated in the opening area and the middle area of the pleated to agglomerate and deposit.展开更多
Methane-air diffusion filtration combustion in a radiative round-jet burner was numerically investigated in this work.The purpose of this study was focused on the effects of porous media porosity and gas velocity on t...Methane-air diffusion filtration combustion in a radiative round-jet burner was numerically investigated in this work.The purpose of this study was focused on the effects of porous media porosity and gas velocity on temperature distribution and CO and NO_(x)emissions.Reduced chemical kinetics was used where air and methane were assumed to be at their stoichiometric ratio,while thermo-physical properties were varied per the solid matrix porosity variation.Combustion characteristics were evaluated based on conduction and radiation as the two primary heat transfer modes within the solid matrix.Numerical simulations were carried out based on a packed bed with 3 mm alumina pellets.Results show that combustion temperature increases while the temperature gradient decreases with the increase in porosity,yielding higher NO_(x),and lower CO emissions.Furthermore,the combustion temperature is the lowest and most uniformly distributed with 1 m/s and 3 m/s gas velocities,wherewith 3 m/s gas velocity,combustion occurs outside of the porous zone.The corresponding NO_(x)and CO emissions are the lowest with 1 m/s gas velocity and increase with the increase in gas velocity from 1 m/s to 10m/s.展开更多
Passive cooling techniques are cost effective and reliable methods of cooling remote radio heads (RRH). This paper investigates the plausibility of a passive cooling technique involving exchanging warm air, from the i...Passive cooling techniques are cost effective and reliable methods of cooling remote radio heads (RRH). This paper investigates the plausibility of a passive cooling technique involving exchanging warm air, from the internal cavity of RRHs, with fresh ambient air, to reduce the operating temperature using natural convection across air filters. The results indicate that, an internal air filter tube structure, with width of the enclosure, running vertically up the middle of an RRH, along with 4 pleat filter sides (2.0 ± 0.5 cm separation) provides the most effective outdoor suitable setup out of those examined. This provides a reduction in temperature of 3.9°K ± 0.4°K in the PA and 4.0°K ± 0.4°K in the radio, and a reduction in mass of 0.45 ± 0.05 kg, and is capable of withstanding water ingress and corrosive conditions including wind driven rain and salt fog.展开更多
The filter paper and activated carbon which filled inside the gas filter have porous media characteristics. In order to study the flow field structure in the filter layer and the activated carbon layer, Computational ...The filter paper and activated carbon which filled inside the gas filter have porous media characteristics. In order to study the flow field structure in the filter layer and the activated carbon layer, Computational Fluid Dynamics method is used to simulate the aerodynamic characteristics of a simplified gas filter. The inertial and viscosity parameters of porous media are solved by Forchheimer equation. The three-dimensional N-S equation and the modified low Reynolds number k-ε turbulence model are adopted to analyze the influence of the explosion-proof plate on the gas filter’s aerodynamic characteristics. The results showed that the air age in the upstream of the activated carbon plates was small, which easily caused the rapid penetration of the Poisonous gas. And in the downstream and around of the activated carbon plates, the air age is larger, formed dead zone, the utilization rate of activated carbon is lower. The explosion-proof plate increases the pressure drop of the gas filter, the air age distribution in the filter layer is more uniform and the utilization rate of filter paper is improved. However, the explosion-proof plate has little influence on the flow field structure of the activated carbon layer.展开更多
Air leakage may significantly affect the effectiveness of mine ventilation by in- creasing the cost of ventilation and arousing problems for ventilation management.Fur- thermore,air leakage may accelerate the process ...Air leakage may significantly affect the effectiveness of mine ventilation by in- creasing the cost of ventilation and arousing problems for ventilation management.Fur- thermore,air leakage may accelerate the process of coal spontaneous combustion and cause gas explosion,thus greatly threatens the safety of coal production.The estimation of air leakage,therefore,have great practical significance.For any ventilation system of coal mines,there is a defined pattern of pressure gradient which drived the mine air to flow in the network,drives possible air leakage to go shortcut as well.Air leakage may occur through ventilation structures such as ventilation doors and fractures of the surroun- dig coal and rock of airways.A concept and the relevent calculation method of the pres- sure gradient matrix was put forward to assist the analysis of potential air leakage routes. A simplified example was used to introduce the application principle of'pressure gradient matrix in identifying all the potential air leaking routes,which offers a deeper understand- ing over the ventilation system and the prevention of coal spontaneous combustion.展开更多
文摘能源危机和温室效应促进了可再生能源的利用,储能技术是解决太阳能、风能波动问题的重要手段。压缩空气储能(Compressed Air Energy Storage,CAES)技术是仅次于抽水蓄能的第二大蓄能技术。目前CAES多是通过洞穴实现,其主要缺点是对地质要求较高,合适的洞穴数量有限,为扩大其应用,可使用地下咸水含水层作为储层。本文介绍了CAES电站的工作原理、优缺点及各国的发展现状,并分析了利用地下咸水含水层进行压缩空气储能的可行性、优点及一些问题与技术方法,如储层内残余烃的影响、氧化与腐蚀作用、颗粒的影响及缓冲气的选择,表明含水层CAES将是拓宽CAES应用的重要途径。
文摘In this study, the three-dimensional physical model of pleated air filtration media was simplified to porous media model, and the calculation parameters of porous media were obtained based on experimental data. The model of V-shaped pleated air filter media is constructed, the height of the media pleat is 50 mm and the pleat thickness is 4 mm, the pleat angle is 3.7°. The Hertz-Mindlin contact model was modified by Johnson Kendall Roberts (JKR) adhesion contact model. The deposition process of particles in media was simulated based on computational fluid dynamics (CFD) theory and discrete element method (DEM). Results show that the CFD–DEM coupling method can be effectively applied to the macro research of pleated air filter media. The particles will form dust layer and dendrite structure on the fiber surface, and the dust layer will affect the subsequent air flow organization, and the dendrite structure will eventually form a “particle wall”. The formation of the “particle wall” will prevent the particles from moving further in the fluid domain, which makes area of pleated angle become the “low efficiency” part about the particle deposition. Compared with area of pleated angle, the particles are concentrated in the opening area and the middle area of the pleated to agglomerate and deposit.
文摘Methane-air diffusion filtration combustion in a radiative round-jet burner was numerically investigated in this work.The purpose of this study was focused on the effects of porous media porosity and gas velocity on temperature distribution and CO and NO_(x)emissions.Reduced chemical kinetics was used where air and methane were assumed to be at their stoichiometric ratio,while thermo-physical properties were varied per the solid matrix porosity variation.Combustion characteristics were evaluated based on conduction and radiation as the two primary heat transfer modes within the solid matrix.Numerical simulations were carried out based on a packed bed with 3 mm alumina pellets.Results show that combustion temperature increases while the temperature gradient decreases with the increase in porosity,yielding higher NO_(x),and lower CO emissions.Furthermore,the combustion temperature is the lowest and most uniformly distributed with 1 m/s and 3 m/s gas velocities,wherewith 3 m/s gas velocity,combustion occurs outside of the porous zone.The corresponding NO_(x)and CO emissions are the lowest with 1 m/s gas velocity and increase with the increase in gas velocity from 1 m/s to 10m/s.
文摘Passive cooling techniques are cost effective and reliable methods of cooling remote radio heads (RRH). This paper investigates the plausibility of a passive cooling technique involving exchanging warm air, from the internal cavity of RRHs, with fresh ambient air, to reduce the operating temperature using natural convection across air filters. The results indicate that, an internal air filter tube structure, with width of the enclosure, running vertically up the middle of an RRH, along with 4 pleat filter sides (2.0 ± 0.5 cm separation) provides the most effective outdoor suitable setup out of those examined. This provides a reduction in temperature of 3.9°K ± 0.4°K in the PA and 4.0°K ± 0.4°K in the radio, and a reduction in mass of 0.45 ± 0.05 kg, and is capable of withstanding water ingress and corrosive conditions including wind driven rain and salt fog.
文摘The filter paper and activated carbon which filled inside the gas filter have porous media characteristics. In order to study the flow field structure in the filter layer and the activated carbon layer, Computational Fluid Dynamics method is used to simulate the aerodynamic characteristics of a simplified gas filter. The inertial and viscosity parameters of porous media are solved by Forchheimer equation. The three-dimensional N-S equation and the modified low Reynolds number k-ε turbulence model are adopted to analyze the influence of the explosion-proof plate on the gas filter’s aerodynamic characteristics. The results showed that the air age in the upstream of the activated carbon plates was small, which easily caused the rapid penetration of the Poisonous gas. And in the downstream and around of the activated carbon plates, the air age is larger, formed dead zone, the utilization rate of activated carbon is lower. The explosion-proof plate increases the pressure drop of the gas filter, the air age distribution in the filter layer is more uniform and the utilization rate of filter paper is improved. However, the explosion-proof plate has little influence on the flow field structure of the activated carbon layer.
基金the National Natural Science Foundation of China(50174045)the Natural Science Foundation of Shaanxi Province China(2006E205)
文摘Air leakage may significantly affect the effectiveness of mine ventilation by in- creasing the cost of ventilation and arousing problems for ventilation management.Fur- thermore,air leakage may accelerate the process of coal spontaneous combustion and cause gas explosion,thus greatly threatens the safety of coal production.The estimation of air leakage,therefore,have great practical significance.For any ventilation system of coal mines,there is a defined pattern of pressure gradient which drived the mine air to flow in the network,drives possible air leakage to go shortcut as well.Air leakage may occur through ventilation structures such as ventilation doors and fractures of the surroun- dig coal and rock of airways.A concept and the relevent calculation method of the pres- sure gradient matrix was put forward to assist the analysis of potential air leakage routes. A simplified example was used to introduce the application principle of'pressure gradient matrix in identifying all the potential air leaking routes,which offers a deeper understand- ing over the ventilation system and the prevention of coal spontaneous combustion.