An in-fiber Mach-Zehnder interferometer is proposed for the discrimination of strain and temperature.The sensor is based on two cascaded standard single mode fibers using three peanut tapers fabricated by simple splic...An in-fiber Mach-Zehnder interferometer is proposed for the discrimination of strain and temperature.The sensor is based on two cascaded standard single mode fibers using three peanut tapers fabricated by simple splicing.The cascaded structure excites more frequency components,which induce four sets of interference dips in the transmission spectrum.One set of the spectrum dips have different sensitivities to temperature and strain from those of the other three.The sensor can discriminate strain and temperature by monitoring the wavelength shifts of two spectrum dips.Repeated experiments are taken both for strain and temperature increasing and decreasing scenarios.Experimental results show that Dip 1 has an average strain sensitivity of-0.911 pm/με and an average temperature sensitivity of 49.98pm/℃.The strain sensitivity for Dip 2 is negligible and its average temperature sensitivity is 60.52pm/℃.The strain and temperature resolutions are±3.82με and±0.33℃.展开更多
We proposed a compact design of an optical biochemical sensor based on the Mach-Zehnder interferometer (MZI), which was coupled by a ring resonator (RR) as a sensing tool. The sensor sensitivity has been determine...We proposed a compact design of an optical biochemical sensor based on the Mach-Zehnder interferometer (MZI), which was coupled by a ring resonator (RR) as a sensing tool. The sensor sensitivity has been determined by power difference at the output ports. The sensor enhancement has been optimized by numerically evaluating the geometrical parameters of the MZ! and RR. A great sensor sensitivity depicted by Fano resonance characteristic has been demonstrated as a function of the round trip phase in the range of 4×10^-4 - 4×10^-4, which was changed by the presence of the sample solution in the sensing area. This optimum sensitivity has been obtained for the values of two coupling coefficients of the MZI k1 =k2 =0.5/mm and the coupling coefficient between the MZI arm and RR KR = 0.5/ram. Furthermore, a good profile of sensitivity exchange has been exhibited by inducing the direct current voltage to the coupling region of k R. Finally, the output power transmission of the ring-coupled arm was depicted as a function of tunable k R.展开更多
基金supported by the National Natural Science Foundation of China(Grant Nos.62005011,61801017,and.62005013)the Beijing Municipal Natural Science Foundation(Grant No.4212009)the Fundamental Research Funds for the Central Universities(Grant No.2020RC015).
文摘An in-fiber Mach-Zehnder interferometer is proposed for the discrimination of strain and temperature.The sensor is based on two cascaded standard single mode fibers using three peanut tapers fabricated by simple splicing.The cascaded structure excites more frequency components,which induce four sets of interference dips in the transmission spectrum.One set of the spectrum dips have different sensitivities to temperature and strain from those of the other three.The sensor can discriminate strain and temperature by monitoring the wavelength shifts of two spectrum dips.Repeated experiments are taken both for strain and temperature increasing and decreasing scenarios.Experimental results show that Dip 1 has an average strain sensitivity of-0.911 pm/με and an average temperature sensitivity of 49.98pm/℃.The strain sensitivity for Dip 2 is negligible and its average temperature sensitivity is 60.52pm/℃.The strain and temperature resolutions are±3.82με and±0.33℃.
文摘We proposed a compact design of an optical biochemical sensor based on the Mach-Zehnder interferometer (MZI), which was coupled by a ring resonator (RR) as a sensing tool. The sensor sensitivity has been determined by power difference at the output ports. The sensor enhancement has been optimized by numerically evaluating the geometrical parameters of the MZ! and RR. A great sensor sensitivity depicted by Fano resonance characteristic has been demonstrated as a function of the round trip phase in the range of 4×10^-4 - 4×10^-4, which was changed by the presence of the sample solution in the sensing area. This optimum sensitivity has been obtained for the values of two coupling coefficients of the MZI k1 =k2 =0.5/mm and the coupling coefficient between the MZI arm and RR KR = 0.5/ram. Furthermore, a good profile of sensitivity exchange has been exhibited by inducing the direct current voltage to the coupling region of k R. Finally, the output power transmission of the ring-coupled arm was depicted as a function of tunable k R.