3D printing,an additive manufacturing based technology for precise 3D construction,is currently widely employed to enhance applicability and function of cell laden scaffolds.Research on novel compatible biomaterials f...3D printing,an additive manufacturing based technology for precise 3D construction,is currently widely employed to enhance applicability and function of cell laden scaffolds.Research on novel compatible biomaterials for bioprinting exhibiting fast crosslinking properties is an essential prerequisite toward advancing 3D printing applications in tissue engineering.Printability to improve fabrication process and cell encapsulation are two of the main factors to be considered in development of 3D bioprinting.Other important factors include but are not limited to printing fidelity,stability,crosslinking time,biocompatibility,cell encapsulation and proliferation,shear-thinning properties,and mechanical properties such as mechanical strength and elasticity.In this review,we recite recent promising advances in bioink development as well as bioprinting methods.Also,an effort has been made to include studies with diverse types of crosslinking methods such as photo,chemical and ultraviolet(UV).We also propose the challenges and future outlook of 3D bioprinting application in medical sciences and discuss the high performance bioinks.展开更多
AIM: To compare and calculate the 3-year refractive results, higher-order aberrations (HOAs), contrast sensitivity (CS) and dry eye parameters after small incision lenticule extraction (SMILE) and wavefront-gui...AIM: To compare and calculate the 3-year refractive results, higher-order aberrations (HOAs), contrast sensitivity (CS) and dry eye parameters after small incision lenticule extraction (SMILE) and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for correction of high myopia and myopic astigmatism. METHODS: In this prospective, non-randomized comparative study, 78 eyes with spherical equivalent (SE) of -8.11±1.09 diopters (D) received a SMILE surgery, and 65 eyes with SE of -8.05±1.12 D received a wavefront-guided FS-LASIK surgery with the VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany) for flap cutting. Visual acuity, manifest refraction, CS, HOAs, ocular surface disease index (OSDI) and tear break-up time (TBUT) were evaluated during a 3-year follow-up. RESULTS: The difference of uncorrected distance visual acuity (UDVA) postoperatively was achieved at lmo and at 3mo, whereas the difference of the mean UDVA between two groups at 3y were not statistically significant (t=-1.59, P=-0.13). The postoperative change of SE was 0.89 D in the FS-LASIK group (t=5.76, P=0.00), and 0.14 D in the SMILE group (t=-0.54, P=0.59) from lmo to 3y after surgery. At 3-year postoperatively, both HOAs and spherical aberrations in the SMILE group were obviously less than those in the FS-LASIK group (P=0.00), but the coma root mean square (RMS) was higher in the SMILE group (0.59±0.26) than in the FS-LASIK group (0.29±0.14, P=0.00). The mesopic CS values between two groups were not statistically significant at 3y postoperatively. Compared with the FS-LASIK group, lower OSDI scores and longer TBUT values were found in the SMILE group at Imo and 3mo postoperatively. With regard to safety, no eye lost any line of CDVA in both groups at 3y after surgery. CONCLUSION: Both SMILE and wavefront-guided FS- LASIK procedures provide good visual outcomes. Both procedures are effective and safe, but SMILE surgery achieve展开更多
AIM:To assess the corneal sensitivity and the incidences of dry eye after small incision lenticule extraction(SMILE) and femtosecond laser-assisted in situ keratomileusis(FSLASIK).METHODS:The Meta-analysis was p...AIM:To assess the corneal sensitivity and the incidences of dry eye after small incision lenticule extraction(SMILE) and femtosecond laser-assisted in situ keratomileusis(FSLASIK).METHODS:The Meta-analysis was performed using Rev Man 5.3.We searched on Pub Med from inception to March 2016.Summary weighted mean difference(WMD) and 95% confidence intervals(CIs) were used to analyze the datum.Random-effects or fixed-effects models were chosen up to between-study heterogeneity.The main outcomes were composed of the Ocular Surface Disease Index(OSDI) scores,tear film break-up time(TBUT),Schirmer Test and corneal sensitivity.RESULTS:Eight eligible studies including 772 eyes(386 in SMILE group and 386 in FS-LASIK group) were identified.The parameters have no significiant difference heterogeneity between SMILE and FS-LASIK group preoperatively.There were significant differences between the two groups in OSDI scores at one and three months postoperatively,in TBUT at one and three months postoperatively,in corneal sensitivity at one week,about one month and three months postoperatively.However,there was no significant difference observed in Schirmer Test at the follow-up periods.CONCLUSION:Compare to FS-LASIK,dry eye and the corneal sensitivity recover better in the SMILE group,in first three months after the surgery.展开更多
基金Authors want to thank the funding support of National Sciences and Engineering Research Council of Canada(NSERC)Discovery Grant,NSERC Accelerator Supplement Award and Canada Foundation for Innovation,and the research support of Hkable3D for 3D printers.
文摘3D printing,an additive manufacturing based technology for precise 3D construction,is currently widely employed to enhance applicability and function of cell laden scaffolds.Research on novel compatible biomaterials for bioprinting exhibiting fast crosslinking properties is an essential prerequisite toward advancing 3D printing applications in tissue engineering.Printability to improve fabrication process and cell encapsulation are two of the main factors to be considered in development of 3D bioprinting.Other important factors include but are not limited to printing fidelity,stability,crosslinking time,biocompatibility,cell encapsulation and proliferation,shear-thinning properties,and mechanical properties such as mechanical strength and elasticity.In this review,we recite recent promising advances in bioink development as well as bioprinting methods.Also,an effort has been made to include studies with diverse types of crosslinking methods such as photo,chemical and ultraviolet(UV).We also propose the challenges and future outlook of 3D bioprinting application in medical sciences and discuss the high performance bioinks.
文摘AIM: To compare and calculate the 3-year refractive results, higher-order aberrations (HOAs), contrast sensitivity (CS) and dry eye parameters after small incision lenticule extraction (SMILE) and wavefront-guided femtosecond laser-assisted laser in situ keratomileusis (FS-LASIK) for correction of high myopia and myopic astigmatism. METHODS: In this prospective, non-randomized comparative study, 78 eyes with spherical equivalent (SE) of -8.11±1.09 diopters (D) received a SMILE surgery, and 65 eyes with SE of -8.05±1.12 D received a wavefront-guided FS-LASIK surgery with the VisuMax femtosecond laser (Carl Zeiss Meditec, Jena, Germany) for flap cutting. Visual acuity, manifest refraction, CS, HOAs, ocular surface disease index (OSDI) and tear break-up time (TBUT) were evaluated during a 3-year follow-up. RESULTS: The difference of uncorrected distance visual acuity (UDVA) postoperatively was achieved at lmo and at 3mo, whereas the difference of the mean UDVA between two groups at 3y were not statistically significant (t=-1.59, P=-0.13). The postoperative change of SE was 0.89 D in the FS-LASIK group (t=5.76, P=0.00), and 0.14 D in the SMILE group (t=-0.54, P=0.59) from lmo to 3y after surgery. At 3-year postoperatively, both HOAs and spherical aberrations in the SMILE group were obviously less than those in the FS-LASIK group (P=0.00), but the coma root mean square (RMS) was higher in the SMILE group (0.59±0.26) than in the FS-LASIK group (0.29±0.14, P=0.00). The mesopic CS values between two groups were not statistically significant at 3y postoperatively. Compared with the FS-LASIK group, lower OSDI scores and longer TBUT values were found in the SMILE group at Imo and 3mo postoperatively. With regard to safety, no eye lost any line of CDVA in both groups at 3y after surgery. CONCLUSION: Both SMILE and wavefront-guided FS- LASIK procedures provide good visual outcomes. Both procedures are effective and safe, but SMILE surgery achieve
基金Supported by the National Natural Science Foundation of China(No.81470648)
文摘AIM:To assess the corneal sensitivity and the incidences of dry eye after small incision lenticule extraction(SMILE) and femtosecond laser-assisted in situ keratomileusis(FSLASIK).METHODS:The Meta-analysis was performed using Rev Man 5.3.We searched on Pub Med from inception to March 2016.Summary weighted mean difference(WMD) and 95% confidence intervals(CIs) were used to analyze the datum.Random-effects or fixed-effects models were chosen up to between-study heterogeneity.The main outcomes were composed of the Ocular Surface Disease Index(OSDI) scores,tear film break-up time(TBUT),Schirmer Test and corneal sensitivity.RESULTS:Eight eligible studies including 772 eyes(386 in SMILE group and 386 in FS-LASIK group) were identified.The parameters have no significiant difference heterogeneity between SMILE and FS-LASIK group preoperatively.There were significant differences between the two groups in OSDI scores at one and three months postoperatively,in TBUT at one and three months postoperatively,in corneal sensitivity at one week,about one month and three months postoperatively.However,there was no significant difference observed in Schirmer Test at the follow-up periods.CONCLUSION:Compare to FS-LASIK,dry eye and the corneal sensitivity recover better in the SMILE group,in first three months after the surgery.