It is a problem to be solved that the experimental selectivity coefficients of ion selective electrodes (ISEs) depend on the activity. This paper studied the new method of determining selectivity coefficients. A mix...It is a problem to be solved that the experimental selectivity coefficients of ion selective electrodes (ISEs) depend on the activity. This paper studied the new method of determining selectivity coefficients. A mixed ion response equation, which was similar to Nicolsky-Eisenman (N-E) equation recommended by IUPAC, was proposed. The equation includes the practical response slope of ISEs to the primary ion and the interfering ion. The selectivity coefficient was defined by the equation instead of the N-E equation. The experimental part of the method is similar to that based on the N-E equation. The values of selectivity coefficients obtained with this method do not depend on the activity whether the electrodes exhibit the Nernst response or non-Nernst response. The feasibility of the new method is illustrated experimentally.展开更多
Two novel heteroatom-bridged his (benzo-12-crown-4 ether)s, i.e. his [2-nitro-4,5 (1,4,7,10-tetraoxadecamethylene) disulfide 1 and diselenide 2, have been synthesized. X ray crystallographic structure was obtained for...Two novel heteroatom-bridged his (benzo-12-crown-4 ether)s, i.e. his [2-nitro-4,5 (1,4,7,10-tetraoxadecamethylene) disulfide 1 and diselenide 2, have been synthesized. X ray crystallographic structure was obtained for 1. Ion selective electrodes (ISE) for Ag+, containing 1 and 2 in PVC membrane as neutral carriers, were prepared, and their selectivity coefficients for Ag^+ (K_(Ag.M)^(pot)) were determined against other heavy metal ions, alkali and alkaline-earth metal ions. and ammonium ion. These ISEs showed excellent Ag^+ selectivities, log K_(Ag.M)^(pot) ≤ -3.8, against most of the interfering canons examined, except for Hg^+.展开更多
文摘It is a problem to be solved that the experimental selectivity coefficients of ion selective electrodes (ISEs) depend on the activity. This paper studied the new method of determining selectivity coefficients. A mixed ion response equation, which was similar to Nicolsky-Eisenman (N-E) equation recommended by IUPAC, was proposed. The equation includes the practical response slope of ISEs to the primary ion and the interfering ion. The selectivity coefficient was defined by the equation instead of the N-E equation. The experimental part of the method is similar to that based on the N-E equation. The values of selectivity coefficients obtained with this method do not depend on the activity whether the electrodes exhibit the Nernst response or non-Nernst response. The feasibility of the new method is illustrated experimentally.
文摘Two novel heteroatom-bridged his (benzo-12-crown-4 ether)s, i.e. his [2-nitro-4,5 (1,4,7,10-tetraoxadecamethylene) disulfide 1 and diselenide 2, have been synthesized. X ray crystallographic structure was obtained for 1. Ion selective electrodes (ISE) for Ag+, containing 1 and 2 in PVC membrane as neutral carriers, were prepared, and their selectivity coefficients for Ag^+ (K_(Ag.M)^(pot)) were determined against other heavy metal ions, alkali and alkaline-earth metal ions. and ammonium ion. These ISEs showed excellent Ag^+ selectivities, log K_(Ag.M)^(pot) ≤ -3.8, against most of the interfering canons examined, except for Hg^+.