期刊文献+
共找到13篇文章
< 1 >
每页显示 20 50 100
MVCT图像引导调强放疗在线检验靶区位置及修正剂量分布的临床应用 被引量:4
1
作者 李丹 邓小武 包尚联 《中华放射肿瘤学杂志》 CSCD 北大核心 2005年第6期508-511,共4页
目的利用在线高能X线计算机体层摄影术(MVCT)重建两组共45例调强放疗患者的三维图像,研究头颈部与前列腺肿瘤患者的治疗摆位在未经修正情况下的体位和靶区位置偏差,及其对照射剂量分布的影响,探索MVCT图像引导放疗的临床应用方法与意义... 目的利用在线高能X线计算机体层摄影术(MVCT)重建两组共45例调强放疗患者的三维图像,研究头颈部与前列腺肿瘤患者的治疗摆位在未经修正情况下的体位和靶区位置偏差,及其对照射剂量分布的影响,探索MVCT图像引导放疗的临床应用方法与意义。方法对实施切层调强放疗患者的计划分布分别以电离室和剂量胶片方法进行体模验证测量,在验证合格前提下用在线MVCT图像与模拟定位的CT图像进行三维融合比较,测量两组患者体位和靶区中心点的偏差,分析两组摆位的系统误差与随机误差。以测量的体位和靶区位移偏差值模拟体位偏差条件,比较模拟条件下测量得到的体模剂量分布与计划剂量分布和正常摆位时的剂量分布差别。结果头颈部和前列腺肿瘤治疗摆位未经修正时靶区的三维位移偏差值分别为(-3.0±2.8)、(-5.4±2.3)、(2.1±2.4)mm和(3.2±2.5)(、-6.4±5.3)、(8.7±3.6)mm。上述位移偏差条件下体模测量的头颈和前列腺照射剂量分布与计划剂量分布的误差分别为8.2%和6.9%。结论在线HVCT能精确快速测量患者体位和靶区位置空间误差,为修正摆位提供准确依据。未经修正时靶区位移误差导致的剂量分布误差可能超出临床允许范围,调强放疗应以在线图像引导验证基础上进行才能保证剂量分布精度。 展开更多
关键词 放射治疗 靶区位置 修正剂量 临床应用 在线高能X线计算机体层摄影术 三维图像 肿瘤治疗
原文传递
Treatment of Massive Low-Grade Chondrosarcoma of Nasal Septum with Helical Tomotherapy: A Case Report 被引量:1
2
作者 Hamit Basaran Timur Koca +10 位作者 Sibel Karaca Ozlem Eser K&iota l&iota nc Fikriye Gul Karauc Okan Ö zdemir Ozan Kuduban Arzu Tatar Sare Ş ipal 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2016年第4期263-269,共7页
Chondrosarcomas are malignant bone tumors which develop as a cartilaginous differentiation of primary mesenchymal cells and the second most frequently seen malignant tumor of the bone after osteosarcoma. These maligna... Chondrosarcomas are malignant bone tumors which develop as a cartilaginous differentiation of primary mesenchymal cells and the second most frequently seen malignant tumor of the bone after osteosarcoma. These malignancies are slowly growing non-epithelial tumors with unknown etiology and most frequently seen during the 4 decades of life. They are frequently localized on pelvis, ribs and long bones. Nasal septum CSs are very rarely seen malignancies. They originate from septal mucosa or cartilage and it is difficult to make a diagnosis unless they reach a certain size. A few cases of CSs with nasal septum have been reported in the literature. In cases of CSs, surgery is the gold standard treatment modality;however in surgically unresectable cases or close to margins, radiotherapy plays a significant role in primary and adjuvant treatment. Based on the position of the tumor in head and neck and extremely closeness of the tumor to vital organs as optic nerve, chiasm and brain, image guided-intensity modulated radiation therapy (IG-IMRT) becomes very effective and reliable modalities and may be a favorable treatment alternative. 展开更多
关键词 CHONDROSARCOMA image guided intensity modulated radiation therapy
下载PDF
图像引导调强放射治疗胸腹部肿瘤的摆位误差分析
3
作者 王剑生 陈磊 《智慧健康》 2022年第6期43-45,共3页
目的研究胸腹部肿瘤中应用图像引导调强放射治疗(Image Guided Radiation Therapy,IGRT)。方法观察对象选择2020年2~4月广东省农垦中心医院收治的20例胸腹部肿瘤患者,全部患者接受瓦里安VitalBEAM IGRT加速器治疗,并经由锥形束CT(Cone b... 目的研究胸腹部肿瘤中应用图像引导调强放射治疗(Image Guided Radiation Therapy,IGRT)。方法观察对象选择2020年2~4月广东省农垦中心医院收治的20例胸腹部肿瘤患者,全部患者接受瓦里安VitalBEAM IGRT加速器治疗,并经由锥形束CT(Cone beam CT,CBCT)技术获得线性摆位误差[左右(x)、头脚(y)、前后(z)]以及旋转摆位误差[u(对应x)、v(对应y)、w(对应z)],展开摆位误差分析。结果①20例患者采集CBCT共441次,各方向的平均摆位误差以“系统误差±随机误差”代表,分别为:x轴是(0.16±0.08)cm,y轴是(0.09±0.14)cm、z轴是(-0.03±0.13)cm、u轴是0.77°±0.26°、v轴是-0.21°±0.28°、w轴是0.21°±0.18°;②x方向的误差最小,而y方向的误差最大;x方向、y方向、z方向的外扩值为0.61cm、1.12cm、0.69cm。结论在胸腹部肿瘤治疗中应用IGRT,可在线纠正摆位误差,做到低损伤、高精度治疗;且为避免摆位误差影响,当计算临床耙体积(Clinical target volume,CTV)外放计划靶体积(Planned harrow volume,PTV)时可在x方向外扩0.64cm,y方向外扩1.15cm,z方向外扩0.83cm。 展开更多
关键词 图像引导调强放射治疗 胸腹部肿瘤 摆位误差
下载PDF
图像引导调强放疗及调强适形放疗治疗中晚期宫颈癌的对比研究 被引量:3
4
作者 罗敬 郑志坚 杨泉富 《广州医科大学学报》 2017年第2期62-65,共4页
目的:探讨图像引导调强放疗+腔内近距离放疗联合顺铂方案及调强适形放疗+腔内近距离放疗联合顺铂方案治疗中晚期宫颈癌的优劣。方法:回顾性分析2010-2016年梅州市人民医院收治的中晚期宫颈癌,50例采取图像引导调强放疗+腔内近距离放疗... 目的:探讨图像引导调强放疗+腔内近距离放疗联合顺铂方案及调强适形放疗+腔内近距离放疗联合顺铂方案治疗中晚期宫颈癌的优劣。方法:回顾性分析2010-2016年梅州市人民医院收治的中晚期宫颈癌,50例采取图像引导调强放疗+腔内近距离放疗联合顺铂方案(IGRT组)治疗,50例采取调强适形放疗+腔内近距离放疗联合顺铂方案(IMRT组)治疗,比较两组近期疗效、急性不良反应发生率。结果:IGRT组完全缓解率为94%,部分缓解率为6%,高于IMRT组(完全缓解率88%,部分缓解率12%);IGRT组Ⅱ级+Ⅲ级皮肤黏膜反应、急性消化道反应、急性泌尿系反应及骨髓抑制的发生率分别为:30%、16%、28%、24%;IMRT组Ⅱ级+Ⅲ级皮肤黏膜反应、急性消化道反应、急性泌尿系反应及骨髓抑制的发生率分别为:32%、36%、30%、46%。两组皮肤黏膜反应及急性泌尿系反应差异无统计学意义(P>0.05),IGRT组骨髓抑制及急性消化道反应小于IMRT组(P<0.05)。结论:图像引导调强放疗+腔内近距离放疗联合顺铂方案治疗中晚期宫颈癌近期疗效确切,优于调强适形放疗+腔内近距离放疗联合顺铂方案,且毒副反应小,有利于治疗的顺利完成。 展开更多
关键词 图像引导调强放疗 调强放疗 DDP方案 中晚期 宫颈癌
下载PDF
体重指数对图像引导乳腺癌调强放射治疗摆位误差的影响 被引量:2
5
作者 史颂琪 李思妹 +2 位作者 曹小飞 肖青 赵美玲 《中国当代医药》 CAS 2023年第14期89-92,共4页
目的探讨体重指数(BMI)对保乳术后乳腺癌患者在图像引导治疗下摆位误差及外扩边界的影响。方法回顾性选取2020年1月至2021年7月广州市第一人民医院接受放射治疗的80例保乳乳腺癌患者作为研究对象,根据BMI将患者分成过轻组(BMI<18.4 k... 目的探讨体重指数(BMI)对保乳术后乳腺癌患者在图像引导治疗下摆位误差及外扩边界的影响。方法回顾性选取2020年1月至2021年7月广州市第一人民医院接受放射治疗的80例保乳乳腺癌患者作为研究对象,根据BMI将患者分成过轻组(BMI<18.4 kg/m^(2))、正常组(18.4 kg/m^(2)≤BMI<24 kg/m^(2))、超重组(24 kg/m^(2)≤BMI<27 kg/m^(2))和肥胖组(BMI≥27 kg/m^(2)),每组20例。放疗时应用锥形束CT(CBCT)进行扫描,采集患者放疗中左右位(LAT)、头脚位(LNG)和腹背位(VRT)三个方向(又分别称X轴、Y轴和Z轴)的摆位误差,计算各组因BMI不同摆位误差的差别,并根据公式MPTV=2.5Σ+0.7σ计算最佳的靶区外扩边界。结果考虑BMI情况下,四组患者X轴和Z轴摆位误差整体比较,差异无统计学意义(P>0.05);四组患者Y轴摆位误差整体比较,差异有统计学意义(P<0.05)。过轻组和正常组X轴上外扩边界相近,超重组和肥胖组X轴上外扩边界相近,但过轻组和正常组小于超重组和肥胖组X轴上的外扩边界;Y轴上的外扩边界随BMI的增大而增大;Z轴上的外扩边界在不同BMI中相近。结论乳腺癌调强放射治疗Y轴摆位误差与BMI存在相关性,随BMI的增大,摆位误差也逐渐增大。不同BMI患者的摆位误差可进一步指导医师确定靶区面积扩边范围,采用不同标准适当扩大或缩小外扩边界,从而提高治疗精度。 展开更多
关键词 体重指数 乳腺癌 图像引导放疗技术 调强放疗 摆位误差
下载PDF
Adaptive Dose-Compensation Technique for Image-Guided Radiotherapy of Prostate Cancer
6
作者 WU Qiu-wen 《Chinese Journal of Biomedical Engineering(English Edition)》 2018年第2期74-80,共7页
Background: For image-guided radiotherapy(IGRT) of prostate cancer, the current standard is online image guidance which can effectively correct setup errors and inter-fraction rigid organ motion. However, planning mar... Background: For image-guided radiotherapy(IGRT) of prostate cancer, the current standard is online image guidance which can effectively correct setup errors and inter-fraction rigid organ motion. However, planning margins are still necessary for deformation and intra-fraction motion. Objective: This paper aims to investigate an adaptive planning technique incorporating offline dose feedback to manage interfraction motion and residuals from online corrections. Methods:Repeated CT scans from 28 patients were studied. Online IG was simulated by matching center-of-mass of prostate. A seven-beam IMRT plan with zero margins was designed for each patient. Dose distribution at each fraction was evaluated based on actual target and OARs from that fraction. Cumulative dose was calculated using deformable registration and compared to initial plan. If deviation exceeded pre-defined 2% threshold in prostate D99 an adaptive planning technique called dose compensation was invoked, in which cumulative dose was fed back to the planning system and dose deficit was made up through boost radiation in future fractions through IMRT. Results: If 2% under-dose was allowed at the end of course, then 11 patients failed. If the same criteria was assessed at the end of each week(every 5 fractions), then 14 patients failed. The average dose deficit for these 14 patients was4.4%. They improved to 2% after weekly compensation. 10(out of 14) patients passed criterion after weekly dose compensation; 3 failed marginally; 1 failed significantly(10% deficit). A more aggressive compensation frequency(every 3 fractions) could reduce the dose deficit to the acceptable level for this patient. The doses to OARs were not significantly different from online IG only without dose compensation.Conclusion: We demonstrated an offline dose compensation technique in prostate IGRT which can effectively account for residual uncertainties uncorrectable in online IG. Dose compensation allows further margin reduction and critical organs sparing. 展开更多
关键词 adaptive radiation therapy image-guided radiation therapy intensity modulated radiation therapy prostate inter-fraction motion
原文传递
功能影像引导下鼻咽癌动态调强放疗原发灶高代谢区的剂量学验证 被引量:3
7
作者 辛勇 黄倩 +4 位作者 郭雯雯 唐天友 李亮 章龙珍 周凤娟 《江苏医药》 CAS 2017年第14期993-997,F0003,共6页
目的对接受功能影像引导动态调强放疗的鼻咽癌患者进行治疗前的剂量学验证,初步探索功能影像引导调强放疗的可行性。方法选取11例接受功能影像引导放疗的Ⅰ~ⅣA期鼻咽癌患者进行治疗前的绝对剂量和相对剂量的验证。采用不同的显像技术(C... 目的对接受功能影像引导动态调强放疗的鼻咽癌患者进行治疗前的剂量学验证,初步探索功能影像引导调强放疗的可行性。方法选取11例接受功能影像引导放疗的Ⅰ~ⅣA期鼻咽癌患者进行治疗前的绝对剂量和相对剂量的验证。采用不同的显像技术(CT、^(18)F-氟代脱氧葡萄糖PET/CT)指导鼻咽癌靶区的勾画与治疗计划的制定,利用Varian 23EX加速器、电离室、I'mRT MatriXX二维电离室矩阵、IBA可拆装体模在治疗前进行绝对剂量与相对剂量验证。结果感兴趣区域的绝对剂量相对误差取值在-5.80%~5.23%(2.39±0.66)%。采用差热分析法,剂量限定在3%或3mm标准条件下,采用300MU/min测量时通过的野数占总野数的87.64%。使用300MU/min测量的gamma通过率高于使用500MU/min测量的gamma通过率(P<0.01)。结论剂量学验证是调强放疗质量控制的必要步骤。使用电离室和I'mRT MatriXX二维电离室矩阵及相应的验证软件可以对鼻咽癌原发灶高代谢区进行剂量学验证,并初步证明功能影像引导动态调强放疗是可行的。 展开更多
关键词 鼻咽癌 功能影像引导动态调强放疗 剂量学验证
原文传递
图像引导调强放射治疗联合特瑞普利单抗治疗老年局部晚期不能手术非小细胞肺癌的效果
8
作者 黄世宝 李瑞锋 蒋才慧 《当代医学》 2023年第27期127-130,共4页
目的探究图像引导调强放射治疗(IGRT)联合特瑞普利单抗治疗局部晚期不能手术治疗的老年非小细胞肺癌(NSCLC)患者的效果。方法选取2019年1—12月泉州市光前医院肿瘤放疗科收治的60例NSCLC患者作为研究对象,随机分为研究组与对照组,每组3... 目的探究图像引导调强放射治疗(IGRT)联合特瑞普利单抗治疗局部晚期不能手术治疗的老年非小细胞肺癌(NSCLC)患者的效果。方法选取2019年1—12月泉州市光前医院肿瘤放疗科收治的60例NSCLC患者作为研究对象,随机分为研究组与对照组,每组30例。对照组使用IGRT技术,研究组在对照组基础上联合特瑞普利单抗治疗,比较两组近期疗效、毒副反应发生情况、生存时间。结果研究组临床有效率为86.67%,高于对照组的60.00%,差异有统计学意义(P<0.05);两组疾病控制率比较差异无统计学意义,两组WBC减少、血红蛋白减少、血小板减少、放射性肺炎、放射性食管炎、乏力、发热、心悸、心律失常、甲状腺功能减退发生情况比较差异无统计学意义,两组中位生存时间比较差异无统计学意义。结论IGRT联合特瑞普利单抗治疗局部晚期不能手术治疗的老年NSCLC患者的疗效显著,毒副反应患者可承受,值得临床推广应用。 展开更多
关键词 肺肿瘤 老年 特瑞普利单抗 图像引导调强放疗
下载PDF
CTVision系统在分析鼻咽癌放疗过程靶区体积及其剂量学变化规律中的应用 被引量:1
9
作者 甘晓根 徐子海 廖福锡 《中国医疗设备》 2015年第11期35-38,46,共5页
目的探讨CTVision系统在分析鼻咽癌放疗过程靶区体积及其剂量学变化规律中的应用价值。方法采用CTVision系统对10例鼻咽癌患者进行图像引导调强放疗,分析鼻咽癌靶区及腮腺体积在放疗过程中的变化规律。并将采集到的CT图像传回计划系统,... 目的探讨CTVision系统在分析鼻咽癌放疗过程靶区体积及其剂量学变化规律中的应用价值。方法采用CTVision系统对10例鼻咽癌患者进行图像引导调强放疗,分析鼻咽癌靶区及腮腺体积在放疗过程中的变化规律。并将采集到的CT图像传回计划系统,重新计算并分析危险器官的剂量。结果靶区及双侧腮腺体积随放疗过程的进展呈现逐渐递减的规律,其中靶区体积和右侧腮腺体积在放疗第4周时与放疗前有明显差异,左侧腮腺体积在放疗第5周时与放疗前有明显差异;且左右侧腮腺所受到的照射剂量随体积缩小而逐渐增加,并与体积缩小程度呈正相关(右侧腮腺r=0.471,P=0.036;左侧腮腺r=0.578,P=0.008)。结论鼻咽癌患者在调强放疗过程中,靶区及腮腺体积会随着放疗进程而逐渐缩小,并导致腮腺受照射剂量增加,故建议在调强放疗的第4~5周重新勾画靶区及危险器官并重新制定放疗计划,以提高鼻咽癌局控率并减少放疗副反应。 展开更多
关键词 CTVision系统 图像引导 鼻咽癌 调强放疗
下载PDF
图像引导适形调强放疗联合比卡鲁胺治疗局部晚期前列腺癌的护理
10
作者 陈世梅 《齐齐哈尔医学院学报》 2014年第11期1667-1668,共2页
目的探讨图像引导适形调强放疗联合比卡鲁胺治疗局部晚期前列腺癌的临床护理。方法对12例局部晚期前列腺癌图像引导适形调强放疗联合比卡鲁胺治疗的临床资料进行回顾性分析,采取治疗前心理护理,治疗期间及治疗后采取相应的护理措施。结... 目的探讨图像引导适形调强放疗联合比卡鲁胺治疗局部晚期前列腺癌的临床护理。方法对12例局部晚期前列腺癌图像引导适形调强放疗联合比卡鲁胺治疗的临床资料进行回顾性分析,采取治疗前心理护理,治疗期间及治疗后采取相应的护理措施。结果本组12例患者中CR 3例,PR 9例,总有效率100%。主要不良反应为放射性直肠炎、放射性膀胱炎,放射性皮炎、骨髓抑制等。结论图像引导适形调强放疗联合比卡鲁胺治疗局部晚期前列腺癌配合有效的护理措施,能有效的减轻治疗的副反应,使患者顺利完成治疗,有利于患者的预后和康复。 展开更多
关键词 图像引导适形调强放疗 比卡鲁胺 护理 前列腺癌
下载PDF
低分割三维适形调强放疗治疗局部进展期胰腺癌的临床观察 被引量:2
11
作者 刘伟 张红雁 +3 位作者 马军 程勇 冉晶晶 李云天 《临床肿瘤学杂志》 CAS 2016年第9期826-830,共5页
目的探讨氟尿嘧啶(5-FU)联合低分割影像引导的三维适形调强放疗治疗局部进展期胰腺癌的疗效和毒副反应。方法收集2011年6月至2014年12月间收治的37例经病理组织学证实的不可切除局部进展期胰腺癌,均采用CT引导下三维适形调强放疗技术,... 目的探讨氟尿嘧啶(5-FU)联合低分割影像引导的三维适形调强放疗治疗局部进展期胰腺癌的疗效和毒副反应。方法收集2011年6月至2014年12月间收治的37例经病理组织学证实的不可切除局部进展期胰腺癌,均采用CT引导下三维适形调强放疗技术,放疗采用大分割3.0~3.1 Gy/次,16次,DT 48~49.6 Gy;同步化疗方案:5-FU 350 mg/m^2,每日1次,一周5次,与放疗同步进行。观察疗效和毒副反应,并随访生存。结果所有患者均完成放疗。同步放化疗获CR 5例,PR 14例,SD 14例,PD 4例,有效率为51.4%(19/37);临床受益反应有效者21例,临床受益率为56.8%(21/37)。同步放化疗期间发生3级以上骨髓抑制7例,严重胆道梗阻1例,胃十二指肠溃疡2例。37例患者1、2年无远处转移生存率分别为36.0%、4.8%;1、2年生存率分别为51.3%、11.6%。至随访截止日期,13例患者出现局部复发,26例患者出现远处转移。结论氟尿嘧啶联合低分割影像引导的适形调强放疗治疗局部进展期胰腺癌疗效较好,毒副反应可耐受。 展开更多
关键词 胰腺癌 影像引导 低分割 三维适形调强放疗 氟尿嘧啶
下载PDF
千伏极CBCT在食管癌调强放疗摆位中的应用 被引量:2
12
作者 王风琴 《浙江临床医学》 2012年第9期1039-1040,共2页
目的探讨图像引导放疗(IGRT)系统在食管癌调强放疗摆位修正的应用。方法应用医科达公司的synergy机载KV-CBCT对23例食管癌调强患者每次照射前获取x线容积图像(X-ray volumetric images,XVI)与计划CT图像及其靶中心进行匹配,获取x... 目的探讨图像引导放疗(IGRT)系统在食管癌调强放疗摆位修正的应用。方法应用医科达公司的synergy机载KV-CBCT对23例食管癌调强患者每次照射前获取x线容积图像(X-ray volumetric images,XVI)与计划CT图像及其靶中心进行匹配,获取x、y、z三个方向的误差,并分析纠正误差。结果23例患者均坚持完成放疗,共做了474次CBCT,其中治疗前320次,摆位误差在X(左右)Y(头脚)Z(前后)三个方向≥3mm,分别为(-0.04±4.63)、(0.07±9.69)、(-0.15±4.33)mm。结论千伏极CBCT在食管癌调强放疗摆位中可以提高等中心摆位精度,检测并调整摆位误差,有效减少放射野边界,减少并发症的发生。 展开更多
关键词 图像引导放疗 千伏极锥形束断层扫描 食管癌 调强放疗 摆位误差
下载PDF
四维锥形束CT对食管癌调强放疗中靶区剂量的影响
13
作者 葛小林 陈佳艳 +3 位作者 王沛沛 李金凯 李彩虹 孙新臣 《浙江临床医学》 2015年第2期210-212,共3页
目的分析四维锥形束CT对食管癌调强放疗中计划靶区及危及器官剂量的影响。方法收集16例食管癌患者,分别设计图像引导放疗计划(IGRT)及非图像引导的调强放疗计划(IMRT),在满足靶区处方剂量要求(95%的体积范围包括PTV95%剂量)... 目的分析四维锥形束CT对食管癌调强放疗中计划靶区及危及器官剂量的影响。方法收集16例食管癌患者,分别设计图像引导放疗计划(IGRT)及非图像引导的调强放疗计划(IMRT),在满足靶区处方剂量要求(95%的体积范围包括PTV95%剂量)的情况下,通过剂量体积直方图(DVH)评价和比较两个计划的双肺、脊髓和计划靶区(PTV)剂量的差异。结果IGRT和IMRT两个计划之间肿瘤计划靶区的最大剂量、最小剂量、平均剂量、包含95%靶区的剂量均很接近,差异无统计学意义(P〉0.05),但IGRT计划中脊髓计划区的最高受量明显较IMRT的低[(38.46±3.34)Gy vs(42.80±7.26)Gy,P〈0.05];〉5Gy的双肺受照体积为(50.8±6.8)%,也明显较IMRT计划的(62.3±5.7)%低,差异均有统计学意义(P〈0.05)。结论IGRT技术在食管癌中的应用减少正常组织的体积及受量,有可能提高临床疗效,为减轻放疗毒性反应提供质量保证。 展开更多
关键词 图像引导的放射治疗 调强放射治疗 剂量学 食管癌
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部