In this study, the mean droplet diameter in the cavity zone and the total mass transfer area of a multi-stage highspeed disperser(HSD) reactor with different packing combinations were measured and evaluated. The effec...In this study, the mean droplet diameter in the cavity zone and the total mass transfer area of a multi-stage highspeed disperser(HSD) reactor with different packing combinations were measured and evaluated. The effects of rotational speed and packing radius, as well as the packing ring radius and numbers, on the mean droplet diameter and the total mass transfer area were evaluated. A model was established to calculate the mass transfer area in the cavity zone in the HSD reactor, and it was found that the packings contribute 61%–82% of the total mass transfer area. A correlation for predicting the mass transfer area in the packing zone was regressed by the dimensionless analysis method. An enhancement factor based on the mass transfer area in the packing zone was proposed to evaluate the effect of packing combination on mass transfer area. Two optimum packing combinations were proposed in consideration of the mean droplet diameter and the enhancement factor.展开更多
Droplet characteristics in the cavity zone of a multi-staged high speed disperser with single inlet were studied in this paper. The influences of both the operating and structural parameters on the mean droplet diamet...Droplet characteristics in the cavity zone of a multi-staged high speed disperser with single inlet were studied in this paper. The influences of both the operating and structural parameters on the mean droplet diameter, size distribution and liquid flux distribution were quantitatively analyzed. The result showed that the mean droplet diameter decreased with the increase of rotational speed and the number of rotors;whilst there is little influence on the inlet flow rate. In the experimental range, the minimum value of mean droplet diameter is 0.57 mm, 0.48 mm, 0.41 mm in the two-staged, three-staged and four-staged rotors, respectively. The Rosin–Rammler(R–R) distribution could describe the droplet size distribution appropriately, and it became uniform with the increase of rotational speed and the number of rotor, while the inlet flow rate had little effect on the droplet size distribution. The liquid flux distribution curves were always unimodal. With the increase of rotational speed, the location of maximum liquid flux ratio moved from zone 3 to zone 4 and this value decreased from 22.1% to 18.1%. Using Coefficient of Variation(CV) to indicate the uniformity of liquid flux distribution, it was found that the CV decreases from 47.5% to 22.7%when the number of rotor increased from 2 to 4.展开更多
基金Supported by the National Natural Science Foundation of China(21676007,21506005)
文摘In this study, the mean droplet diameter in the cavity zone and the total mass transfer area of a multi-stage highspeed disperser(HSD) reactor with different packing combinations were measured and evaluated. The effects of rotational speed and packing radius, as well as the packing ring radius and numbers, on the mean droplet diameter and the total mass transfer area were evaluated. A model was established to calculate the mass transfer area in the cavity zone in the HSD reactor, and it was found that the packings contribute 61%–82% of the total mass transfer area. A correlation for predicting the mass transfer area in the packing zone was regressed by the dimensionless analysis method. An enhancement factor based on the mass transfer area in the packing zone was proposed to evaluate the effect of packing combination on mass transfer area. Two optimum packing combinations were proposed in consideration of the mean droplet diameter and the enhancement factor.
基金Supported by ‘‘The Design and Optimisation of High Speed Rotating Mixing Nozzles for Liquid-Liquid Applications” PhD Studentship provided by Huntsman Europe(Belgium)
文摘Droplet characteristics in the cavity zone of a multi-staged high speed disperser with single inlet were studied in this paper. The influences of both the operating and structural parameters on the mean droplet diameter, size distribution and liquid flux distribution were quantitatively analyzed. The result showed that the mean droplet diameter decreased with the increase of rotational speed and the number of rotors;whilst there is little influence on the inlet flow rate. In the experimental range, the minimum value of mean droplet diameter is 0.57 mm, 0.48 mm, 0.41 mm in the two-staged, three-staged and four-staged rotors, respectively. The Rosin–Rammler(R–R) distribution could describe the droplet size distribution appropriately, and it became uniform with the increase of rotational speed and the number of rotor, while the inlet flow rate had little effect on the droplet size distribution. The liquid flux distribution curves were always unimodal. With the increase of rotational speed, the location of maximum liquid flux ratio moved from zone 3 to zone 4 and this value decreased from 22.1% to 18.1%. Using Coefficient of Variation(CV) to indicate the uniformity of liquid flux distribution, it was found that the CV decreases from 47.5% to 22.7%when the number of rotor increased from 2 to 4.