The water-soluble carboxymethyl-cyclodextrin polymer (CM-CD polymer) was synthesized and used as capillary electrophoresis chiral selector. Verrapamil and thiopentorusodium were well separated using CM-CD polymer as c...The water-soluble carboxymethyl-cyclodextrin polymer (CM-CD polymer) was synthesized and used as capillary electrophoresis chiral selector. Verrapamil and thiopentorusodium were well separated using CM-CD polymer as chiral selector.展开更多
Polycyclic aromatic hydrocarbons(PAHs)/heavy metals/fluorine(F) mixed-contaminated sites caused by abandoned metallurgic plants are receiving wide attention. To address the associated environmental problems,this s...Polycyclic aromatic hydrocarbons(PAHs)/heavy metals/fluorine(F) mixed-contaminated sites caused by abandoned metallurgic plants are receiving wide attention. To address the associated environmental problems,this study was initiated to investigate the feasibility of using carboxymethyl-β-cyclodextrin(CMCD) and carboxymethyl chitosan(CMC) solution to enhance ex situ soil washing for extracting mixed contaminants. Further,Tenax extraction method was combined with a first-three-compartment model to evaluate the environmental risk of residual PAHs in washed soil. In addition,the redistribution of heavy metals/F after decontamination was also estimated using a sequential extraction procedure. Three successive washing cycles using50 g/L CMCD and 5 g/L CMC solution were effective to remove 94.3% of total PAHs,93.2% of Pb,85.8% of Cd,93.4% of Cr,83.2% of Ni and 97.3% of F simultaneously. After the 3rd washing,the residual PAHs mainly existed as very slowly desorbing fractions,which were in the form of well-aged,well-sequestered compounds; while the remaining Pb,Cd,Cr,Ni and F mainly existed as Fe–Mn oxide and residual fractions,which were always present in stable mineral forms or bound to non-labile soil fractions. Therefore,this combined cleanup strategy proved to be effective and environmentally friendly.展开更多
目的建立以羧甲基-β-环糊精(carboxymethyl-β-cyclodextrin,CM-β-CD)为手性选择剂的毛细管电泳法拆分氯苯那敏、羟氯喹、班布特罗和沙丁胺醇4种手性药物。方法采用未涂层石英毛细管柱,背景电解质为Na H2PO4缓冲溶液,分离电压为20 k ...目的建立以羧甲基-β-环糊精(carboxymethyl-β-cyclodextrin,CM-β-CD)为手性选择剂的毛细管电泳法拆分氯苯那敏、羟氯喹、班布特罗和沙丁胺醇4种手性药物。方法采用未涂层石英毛细管柱,背景电解质为Na H2PO4缓冲溶液,分离电压为20 k V。考察了CM-β-CD的质量浓度、缓冲溶液质量浓度和p H值对拆分的影响。结果在最佳分离条件下,氯苯那敏、羟氯喹、班布特罗和沙丁胺醇的分离度分别为10.49、6.97、3.75和1.56。结论 CM-β-CD对研究的4种药物有非常高的对映体选择性。展开更多
文摘The water-soluble carboxymethyl-cyclodextrin polymer (CM-CD polymer) was synthesized and used as capillary electrophoresis chiral selector. Verrapamil and thiopentorusodium were well separated using CM-CD polymer as chiral selector.
基金supported by the National Natural Science Foundation of China (Nos.41030531,41001335G,21377138 and 41271464b)
文摘Polycyclic aromatic hydrocarbons(PAHs)/heavy metals/fluorine(F) mixed-contaminated sites caused by abandoned metallurgic plants are receiving wide attention. To address the associated environmental problems,this study was initiated to investigate the feasibility of using carboxymethyl-β-cyclodextrin(CMCD) and carboxymethyl chitosan(CMC) solution to enhance ex situ soil washing for extracting mixed contaminants. Further,Tenax extraction method was combined with a first-three-compartment model to evaluate the environmental risk of residual PAHs in washed soil. In addition,the redistribution of heavy metals/F after decontamination was also estimated using a sequential extraction procedure. Three successive washing cycles using50 g/L CMCD and 5 g/L CMC solution were effective to remove 94.3% of total PAHs,93.2% of Pb,85.8% of Cd,93.4% of Cr,83.2% of Ni and 97.3% of F simultaneously. After the 3rd washing,the residual PAHs mainly existed as very slowly desorbing fractions,which were in the form of well-aged,well-sequestered compounds; while the remaining Pb,Cd,Cr,Ni and F mainly existed as Fe–Mn oxide and residual fractions,which were always present in stable mineral forms or bound to non-labile soil fractions. Therefore,this combined cleanup strategy proved to be effective and environmentally friendly.