应用容性设备绝缘带电检测技术对内蒙古超高压供电局500 k V永圣域变电站的2组220 k V电流互感器进行检测,通过安装在被测电流互感器上的在线监测系统实时测量电压、电流信号和运行电压下电容量、相对介质损耗值,判断设备的绝缘状态。...应用容性设备绝缘带电检测技术对内蒙古超高压供电局500 k V永圣域变电站的2组220 k V电流互感器进行检测,通过安装在被测电流互感器上的在线监测系统实时测量电压、电流信号和运行电压下电容量、相对介质损耗值,判断设备的绝缘状态。试验结果证明,容性设备绝缘带电检测技术可以判断容性设备的绝缘状态,为容性设备绝缘带电检测技术的进一步推广奠定了基础。展开更多
The effects of parasitic capacitance in induction motor system are unnoticed when it is fed from the AC line, but they are obvious when supplied directly from a PWM inverter. Consequently, many parasitic problems occu...The effects of parasitic capacitance in induction motor system are unnoticed when it is fed from the AC line, but they are obvious when supplied directly from a PWM inverter. Consequently, many parasitic problems occur, such as motor to earth leakage current, bearing current, incoming line current distortion and uneven distribution of electrical stresses along the winding. On the basis of the uniform transmission line principle, a complete equivalent circuit of the PWM inverter fed motor system is presented, based on which all the capacitive parasitic problems mentioned above are analyzed and simulated by means of PSPICE. All the results are consistent with the existing ones.展开更多
兆瓦级光伏电站发电单元通常是由2台500 k W并网逆变器和1台1 MVA三相辐向双分裂升压变压器构成,而辐向升压变压器低压绕组间存在较大的分布电容,常发生2台光伏并网逆变器共同运行困难的问题。针对上述问题,对采用三相辐向升压变压器的...兆瓦级光伏电站发电单元通常是由2台500 k W并网逆变器和1台1 MVA三相辐向双分裂升压变压器构成,而辐向升压变压器低压绕组间存在较大的分布电容,常发生2台光伏并网逆变器共同运行困难的问题。针对上述问题,对采用三相辐向升压变压器的光伏发电单元进行了等效建模,分析了变压器低压绕组间分布电容对双逆变器共同运行的影响机理。分析结果表明,并联在变压器两低压侧的2台逆变器之间存在漏电流回路,光伏发电单元中延后并网的逆变器直流母线电压升高导致双逆变器共同运行困难。通过仿真验证了机理分析的正确性。最后,提出了2种解决办法,并进行了仿真和实验验证。展开更多
文摘应用容性设备绝缘带电检测技术对内蒙古超高压供电局500 k V永圣域变电站的2组220 k V电流互感器进行检测,通过安装在被测电流互感器上的在线监测系统实时测量电压、电流信号和运行电压下电容量、相对介质损耗值,判断设备的绝缘状态。试验结果证明,容性设备绝缘带电检测技术可以判断容性设备的绝缘状态,为容性设备绝缘带电检测技术的进一步推广奠定了基础。
文摘The effects of parasitic capacitance in induction motor system are unnoticed when it is fed from the AC line, but they are obvious when supplied directly from a PWM inverter. Consequently, many parasitic problems occur, such as motor to earth leakage current, bearing current, incoming line current distortion and uneven distribution of electrical stresses along the winding. On the basis of the uniform transmission line principle, a complete equivalent circuit of the PWM inverter fed motor system is presented, based on which all the capacitive parasitic problems mentioned above are analyzed and simulated by means of PSPICE. All the results are consistent with the existing ones.
文摘兆瓦级光伏电站发电单元通常是由2台500 k W并网逆变器和1台1 MVA三相辐向双分裂升压变压器构成,而辐向升压变压器低压绕组间存在较大的分布电容,常发生2台光伏并网逆变器共同运行困难的问题。针对上述问题,对采用三相辐向升压变压器的光伏发电单元进行了等效建模,分析了变压器低压绕组间分布电容对双逆变器共同运行的影响机理。分析结果表明,并联在变压器两低压侧的2台逆变器之间存在漏电流回路,光伏发电单元中延后并网的逆变器直流母线电压升高导致双逆变器共同运行困难。通过仿真验证了机理分析的正确性。最后,提出了2种解决办法,并进行了仿真和实验验证。