摘要
主要对GB 19510.4-2009标准规定的容性泄漏电流的测试方法及要求进行了分析,明确了试验条件、仪器设备、操作方法及标准中未作规定的频率的限值选取方法等,并通过实例说明如何判定所测容性泄漏电流是否符合标准要求,可以为采用标准的相关厂家提供指导和参考。
This paper mainly analyzes the testing method and requirement of leakage current according to the standard GB 19510.4 -2009, and defines the testing condition, requirement of equipment, operating method and the selection of the limits for the frequency not defined. Also, the judgment, whether the measured results of capacitive leakage current comply with the requirement of the standard or not, is clarified by examples, which can give instructions and references for the manufacturers using the standard.
出处
《中国照明电器》
2012年第1期30-34,共5页
China Light & Lighting
关键词
电子镇流器
容性泄漏电流
启动时间
限值
electronic ballasts
capacitive leakage current
starting time
limits