期刊文献+
共找到4篇文章
< 1 >
每页显示 20 50 100
DC-Link Capacitor Optimization in AC–DC Converter by Load Current Prediction
1
作者 V.V.Nijil P.Selvan 《Intelligent Automation & Soft Computing》 SCIE 2023年第4期1043-1062,共20页
Alternating Current–Direct Current(AC–DC)converters require a high value bulk capacitor or afilter capacitor between the DC–DC conversion stages,which in turn causes many problems in the design of a AC–DC converter... Alternating Current–Direct Current(AC–DC)converters require a high value bulk capacitor or afilter capacitor between the DC–DC conversion stages,which in turn causes many problems in the design of a AC–DC converter.The component package size for this capacitor is large due to its high voltage rating and capacitance value.In addition,the high charging current creates more pro-blems during the product compliance testing phase.The shelf life of these specific high value capacitors is less than that of Multilayer Ceramic Capacitors(MLCC),which limits its use for the highly reliable applications.This paper presents a fea-sibility study to overcome these two problems by adding a few sensing mechan-isms to the typical AC–DC converter topology.In majority of the AC–DC converter,Al-Elko capacitor takes approximately 3%to 5%of the converter size.The proposed method reduces this to approximately 50%size and so it effectively approximates 2%to 3%size reduction in converter size.The proposed method basically works based on the load current prediction method and hence it is highly suitable for the constant load application.Moreover,the converter response time increases in this method,which limit its application in high-speed systems.The high temperature application of Al-Elko capacitor is limited because of its poor performance,which is significantly rectified by replacing the Al-Elko with MLCC as it delivers good performance in high temperature. 展开更多
关键词 dc link capacitor optimization acdc converter input ripple reduction aluminum capacitor removal CRP value engineering
下载PDF
Technology and engineering application of cross area HVDC interconnection system high-precision simulation modeling based on ADPSS 被引量:3
2
作者 Weijie Zheng Jianfeng Yan +2 位作者 Xujiang Chen Shuwen Xu Yalou Li 《Global Energy Interconnection》 2018年第5期627-635,共9页
In recent years, a large number of high voltage direct current(HVDC) transmission projects have been connected to AC systems. This has started to have an impact on AC/DC hybrid power grids, particularly receiving term... In recent years, a large number of high voltage direct current(HVDC) transmission projects have been connected to AC systems. This has started to have an impact on AC/DC hybrid power grids, particularly receiving terminal power grids. An HVDC system is a large-scale power electronic integrated nonlinear system, and it includes a primary system and a control and protection system. Hence, the precision and degree of detail of HVDC systems directly affect the actual effect of simulation. In recent years, in the case of the normal operation and failure of AC power grids, the abnormal fluctuation and even locking of HVDC systems caused by the inappropriate strategies of the control and protection system component have strongly affected power grids. This has significantly affected the safety and stability of receiving power grids and normal operation. In this study, the actual engineering HVDC control logic provided by a manufacturer is analyzed and simulated based on the user defined component library of the ADPSS electromagnetic transient calculation program, and an HVDC control model based on an actual system is established. The accuracy of the DC control custom model based on ADPSS is verified through the simulation of an actual power grid. 展开更多
关键词 ADPSS HVdc control and protection SYSTEM Detailed ELECTROMAGNETIC transient simulation acdc large power grid SYSTEM
下载PDF
High-temperature characteristics of SiC module and 100 kW SiC AC–DC converter at a junction temperature of 180 ℃
3
作者 Juanjuan Lu Zhe Zhou +3 位作者 Jianhong Hao Yi Hao Hao Zhang Ruixiang Hao 《Global Energy Interconnection》 2019年第6期522-531,共10页
High-temperature,high-power converters have gained importance in industrial applications given their ability to operate in adverse environments,such as in petroleum exploration,multi-electric aircrafts,and electric ve... High-temperature,high-power converters have gained importance in industrial applications given their ability to operate in adverse environments,such as in petroleum exploration,multi-electric aircrafts,and electric vehicles.SiC metaloxide-semiconductor field-effect transistor(MOSFET),a new,wide bandgap,high-temperature device,is the key component of these converters.In this study,the static and dynamic characteristics of the SiC MOSFET,half-bridge module,are investigated at the junction temperature of 180℃.A simplified experimental method is then proposed pertaining to the power operation of the SiC module at 180℃.This method is based on the use of a thermal resistance test platform and is proven convenient for the study of heat dissipation characteristics.The high-temperature characteristics of the module are verified based on the conducted experiments.Accordingly,a 100 kW high-temperature converter is built,and the test results show that the SiC converter can operate at a junction temperature of 180℃in a stable manner in compliance with the requirements of high-temperature,high-power applications. 展开更多
关键词 SiC MOSFET module Static and dynamic characteristics Power operation experimental method Heat dissipation characteristics SiC ac-dc converter
下载PDF
Effects of temperature on creepage discharge characteristics in oil-impregnated pressboard insulation under combined AC–DC voltage
4
作者 Fubao JIN Yuanxiang ZHOU +2 位作者 Bin LIANG Zhongliu ZHOU Ling ZHANG 《Plasma Science and Technology》 SCIE EI CAS CSCD 2019年第5期14-22,共9页
Due to the complexity of the valve side winding voltage of the converter transformer, the insulation characteristics of the oil-impregnated pressboard(OIP) of the converter transformer are different from those of the ... Due to the complexity of the valve side winding voltage of the converter transformer, the insulation characteristics of the oil-impregnated pressboard(OIP) of the converter transformer are different from those of the traditional AC transformer. The study on effect of temperature on the creeping discharge characteristics of OIP under combined AC–DC voltage is seriously inadequate. Therefore, this paper investigates the characteristics of OIP creepage discharge under combined AC–DC voltage and discusses the influence of temperature on creepage discharge characteristics under different temperatures from 70 °C to 110 °C. The experimental results show that the partial discharge inception voltage and flashover voltage decrease with increasing temperature. The times of low amplitude discharge(LAD) decrease and amplitude of LAD increases. Simultaneously, the times of high amplitude discharge(HAD) gradually increase at each stage of creepage discharge with higher temperature. The analysis indicates that the charge carriers easily accumulate and quickly migrate directional movement along the electric field ahead of discharging. The residual charge carriers are more easily dissipated after discharging.The ‘hump’ region of LAD moves to the direction of higher discharge magnitude. The interval time between two continuous discharges is shortened obviously. The concentration of HAD accelerates the development of OIP insulation creepage discharge. The temperature had an accelerating effect on the development of discharge in the OIP under applying voltage. 展开更多
关键词 oil-impregnated PRESSBOARD INSULATION combined ac-dc VOLTAGE inception VOLTAGE CREEPAGE discharge temperature flashover VOLTAGE
下载PDF
上一页 1 下一页 到第