期刊文献+

Technology and engineering application of cross area HVDC interconnection system high-precision simulation modeling based on ADPSS 被引量:3

Technology and engineering application of cross area HVDC interconnection system high-precision simulation modeling based on ADPSS
下载PDF
导出
摘要 In recent years, a large number of high voltage direct current(HVDC) transmission projects have been connected to AC systems. This has started to have an impact on AC/DC hybrid power grids, particularly receiving terminal power grids. An HVDC system is a large-scale power electronic integrated nonlinear system, and it includes a primary system and a control and protection system. Hence, the precision and degree of detail of HVDC systems directly affect the actual effect of simulation. In recent years, in the case of the normal operation and failure of AC power grids, the abnormal fluctuation and even locking of HVDC systems caused by the inappropriate strategies of the control and protection system component have strongly affected power grids. This has significantly affected the safety and stability of receiving power grids and normal operation. In this study, the actual engineering HVDC control logic provided by a manufacturer is analyzed and simulated based on the user defined component library of the ADPSS electromagnetic transient calculation program, and an HVDC control model based on an actual system is established. The accuracy of the DC control custom model based on ADPSS is verified through the simulation of an actual power grid. In recent years, a large number of high voltage direct current(HVDC) transmission projects have been connected to AC systems. This has started to have an impact on AC/DC hybrid power grids, particularly receiving terminal power grids. An HVDC system is a large-scale power electronic integrated nonlinear system, and it includes a primary system and a control and protection system. Hence, the precision and degree of detail of HVDC systems directly affect the actual effect of simulation. In recent years, in the case of the normal operation and failure of AC power grids, the abnormal fluctuation and even locking of HVDC systems caused by the inappropriate strategies of the control and protection system component have strongly affected power grids. This has significantly affected the safety and stability of receiving power grids and normal operation. In this study, the actual engineering HVDC control logic provided by a manufacturer is analyzed and simulated based on the user defined component library of the ADPSS electromagnetic transient calculation program, and an HVDC control model based on an actual system is established. The accuracy of the DC control custom model based on ADPSS is verified through the simulation of an actual power grid.
出处 《Global Energy Interconnection》 2018年第5期627-635,共9页 全球能源互联网(英文版)
基金 supported by National Key Research and Development Program of China-High performance analysis and situational awareness technology for interconnected power grids
关键词 ADPSS HVDC control and protection SYSTEM Detailed ELECTROMAGNETIC transient simulation AC–DC large power grid SYSTEM ADPSS HVDC control and protection system Detailed electromagnetic transient simulation AC–DC large power grid system
  • 相关文献

参考文献2

二级参考文献34

共引文献39

同被引文献24

引证文献3

二级引证文献20

相关作者

内容加载中请稍等...

相关机构

内容加载中请稍等...

相关主题

内容加载中请稍等...

浏览历史

内容加载中请稍等...
;
使用帮助 返回顶部