How to accurately evaluate the direct-strike lightning protection is one of the key issues in the design of transmission lines. In this paper, three important issues in applying the fractal simulation to the lightning...How to accurately evaluate the direct-strike lightning protection is one of the key issues in the design of transmission lines. In this paper, three important issues in applying the fractal simulation to the lightning protection of transmission lines were discussed, including the criteria and implementation of upward leader inception, the connection with the magnitude of lightning current, and the calculation and control of fractal dimensions. Then we conducted the simulation iterately, leading to statistical results, which indicate that even if the transmission line satisfies the perfect shielding condition, shielding failure fault remains possible. Furthermore, we calculated the shielding failure fault rates of an EHV line with different ground obliquities and distribution of strike points over the interval between two neighboring towers along a UHV-DC line to find out the weak point of transmission-line lightning protection. This work provides a promising approach for improving the lightning protection property of transmission lines by optimizing the configuration of shielding wires and phase or pole conductors.展开更多
基金Supported by the National Nature Science Foundation of China (Grant No. 50737001)the National Basic Research Program of China ("973" Project) (Grant No. 2009CB724504)
文摘How to accurately evaluate the direct-strike lightning protection is one of the key issues in the design of transmission lines. In this paper, three important issues in applying the fractal simulation to the lightning protection of transmission lines were discussed, including the criteria and implementation of upward leader inception, the connection with the magnitude of lightning current, and the calculation and control of fractal dimensions. Then we conducted the simulation iterately, leading to statistical results, which indicate that even if the transmission line satisfies the perfect shielding condition, shielding failure fault remains possible. Furthermore, we calculated the shielding failure fault rates of an EHV line with different ground obliquities and distribution of strike points over the interval between two neighboring towers along a UHV-DC line to find out the weak point of transmission-line lightning protection. This work provides a promising approach for improving the lightning protection property of transmission lines by optimizing the configuration of shielding wires and phase or pole conductors.