A Double Shear Model(DSM) was used in a numerical simulation on bolted rock joint shearing performance.An entire bolt deformed as the letter'U'under a shear load between two joints.Near the bolt-joint intersec...A Double Shear Model(DSM) was used in a numerical simulation on bolted rock joint shearing performance.An entire bolt deformed as the letter'U'under a shear load between two joints.Near the bolt-joint intersection,the bolt partly deformed as the letter'Z'.There were two critical points along the bolt:one was at the bolt-joint intersection with zero bending moment and the other at the maximum bending moment(plastic hinge) with zero shear stress.The blocks on two sides slid along the bolt as it deformed. A separation area was found between the two joint contact surfaces of the middle rock block and sided block.This area of separation was related to bolt diameter and external forces.We assume that this area is related to the work of external forces.Further research is needed.展开更多
Shearing behavior and failure mechanism of bolt-grout interface are of great significance for load transfer capacity and design of rock bolting system.In this paper,direct shear tests on bolt-grout interfaces under co...Shearing behavior and failure mechanism of bolt-grout interface are of great significance for load transfer capacity and design of rock bolting system.In this paper,direct shear tests on bolt-grout interfaces under constant normal load(CNL) conditions were conducted to investigate the effects of bolt profile(i.e.rib spacing and rib height) and grout mixture on the bolt-grout interface in terms of mechanical behaviors and failure modes.Test results showed that the peak shear strength and the deformation capacity of the bolt-grout interface are highly dependent on the bolt profile and grout mixture,suggesting that bolt performances can be optimized,which were unfortunately ignored in the previous studies.A new interface failure mode,i.e.'sheared-crush' mode,was proposed,which was characterized by progressive crush failure of the grout asperities between steel ribs during shearing.It was shown that the interface failure mode mainly depends on the normal stress level and rib spacing,compared with the rib height and grout mixture for the range of tested parameters in this study.展开更多
The mechanical properties of bolts are important factors affecting the shear behavior of bolted joints.In this study,tensile and pure shear tests were conducted on five kinds of bolts made from different materials to ...The mechanical properties of bolts are important factors affecting the shear behavior of bolted joints.In this study,tensile and pure shear tests were conducted on five kinds of bolts made from different materials to measure their tensile and shear parameters.Direct shear tests were conducted to analyze the effects of tensile and shear strength parameters on the shear behavior of bolted joints.The test results showed that the mechanical properties of bolts made from different materials were clearly different and that these differences mainly affected the plastic deformation stage of the bolted joints.The larger the bolt elongation was,the larger the joint shear displacement at bolt failure.The tensile and shear strengths of the bolts were positively correlated with the shear strength of the bolted joints.According to the standard regression analysis,the bolt shear strength had a greater influence than the bolt tensile strength on the bolt contributions when the bolts were perpendicular to the joint surface.Based on the empirical equation for the bolt contribution proposed by Spang,the maximum shear loads in the pure shear test were introduced,and a new equation was established to predict the contributions of bolts.The prediction results obtained using the modified equation were in good agreement with the experimental results.展开更多
The bolt anchoring force is closely related to the shear properties of the anchor interface. The shear stress distribution of full-length grouted bolts is analyzed based on the stress-strain relationship among the bol...The bolt anchoring force is closely related to the shear properties of the anchor interface. The shear stress distribution of full-length grouted bolts is analyzed based on the stress-strain relationship among the bolt, grout, rock mass and bond interface,considering the shear properties of the grout and contact interface bonding behavior. In this case, the interfacial shear stress of the grout and rock mass and the bolt axial force are obtained under pull-out and normal working conditions. The results show that the peak shear stress of the interface with the shear deformation of the bond interface is significantly lower than that without it when the pull-out force is applied. When designing bolt parameters of grade IV and V rock mass, the relative deformation between the rock mass and anchor should be considered, with a “unimodal” to “bimodal” shear stress distribution.In the case of a low elastic modulus of rock masses,both the shear stress concentration and distribution range are obvious, and the neutral point is near the bolt head. As the elastic modulus increases, the shear stress concentration and distribution range are reduced, and the neutral point moves towards the distal end. As a result, the optimum length of fulllength grouted bolts can be determined by in-situ pull-out tests and decreases with the increased elastic modulus of the rock mass.展开更多
基金Financial support from the National Natural Science Foundation of China(No.50978251)the National Government Building High-Level University Graduate Programs of the China Scholarship Council
文摘A Double Shear Model(DSM) was used in a numerical simulation on bolted rock joint shearing performance.An entire bolt deformed as the letter'U'under a shear load between two joints.Near the bolt-joint intersection,the bolt partly deformed as the letter'Z'.There were two critical points along the bolt:one was at the bolt-joint intersection with zero bending moment and the other at the maximum bending moment(plastic hinge) with zero shear stress.The blocks on two sides slid along the bolt as it deformed. A separation area was found between the two joint contact surfaces of the middle rock block and sided block.This area of separation was related to bolt diameter and external forces.We assume that this area is related to the work of external forces.Further research is needed.
基金supported by the Key Projects of the Yalong River Joint Fund of the National Natural Science Foundation of China(Grant No.U1865203)the National Natural Science Foundation of China(Grant No.51279201)+1 种基金Special project of the National Natural Science Foundation of China(Grant No.41941018)The partial support from the Youth Innovation Promotion Association,Chinese Academy of Sciences。
文摘Shearing behavior and failure mechanism of bolt-grout interface are of great significance for load transfer capacity and design of rock bolting system.In this paper,direct shear tests on bolt-grout interfaces under constant normal load(CNL) conditions were conducted to investigate the effects of bolt profile(i.e.rib spacing and rib height) and grout mixture on the bolt-grout interface in terms of mechanical behaviors and failure modes.Test results showed that the peak shear strength and the deformation capacity of the bolt-grout interface are highly dependent on the bolt profile and grout mixture,suggesting that bolt performances can be optimized,which were unfortunately ignored in the previous studies.A new interface failure mode,i.e.'sheared-crush' mode,was proposed,which was characterized by progressive crush failure of the grout asperities between steel ribs during shearing.It was shown that the interface failure mode mainly depends on the normal stress level and rib spacing,compared with the rib height and grout mixture for the range of tested parameters in this study.
基金funded by the National Natural Science Foundation of China(Nos.41931295,41877258)the China Postdoctoral Science Foundation(No.2022M712953)+1 种基金the Open foundation of State Key Laboratory of Geohazard Prevention and Geoenvironment Protection(No.SKLGP2022K001)the China Three Gorges Corporation(No.2019073)。
文摘The mechanical properties of bolts are important factors affecting the shear behavior of bolted joints.In this study,tensile and pure shear tests were conducted on five kinds of bolts made from different materials to measure their tensile and shear parameters.Direct shear tests were conducted to analyze the effects of tensile and shear strength parameters on the shear behavior of bolted joints.The test results showed that the mechanical properties of bolts made from different materials were clearly different and that these differences mainly affected the plastic deformation stage of the bolted joints.The larger the bolt elongation was,the larger the joint shear displacement at bolt failure.The tensile and shear strengths of the bolts were positively correlated with the shear strength of the bolted joints.According to the standard regression analysis,the bolt shear strength had a greater influence than the bolt tensile strength on the bolt contributions when the bolts were perpendicular to the joint surface.Based on the empirical equation for the bolt contribution proposed by Spang,the maximum shear loads in the pure shear test were introduced,and a new equation was established to predict the contributions of bolts.The prediction results obtained using the modified equation were in good agreement with the experimental results.
基金funded by the Natural Science Foundation of China(Grants Nos.52179113,42207199,41831278)。
文摘The bolt anchoring force is closely related to the shear properties of the anchor interface. The shear stress distribution of full-length grouted bolts is analyzed based on the stress-strain relationship among the bolt, grout, rock mass and bond interface,considering the shear properties of the grout and contact interface bonding behavior. In this case, the interfacial shear stress of the grout and rock mass and the bolt axial force are obtained under pull-out and normal working conditions. The results show that the peak shear stress of the interface with the shear deformation of the bond interface is significantly lower than that without it when the pull-out force is applied. When designing bolt parameters of grade IV and V rock mass, the relative deformation between the rock mass and anchor should be considered, with a “unimodal” to “bimodal” shear stress distribution.In the case of a low elastic modulus of rock masses,both the shear stress concentration and distribution range are obvious, and the neutral point is near the bolt head. As the elastic modulus increases, the shear stress concentration and distribution range are reduced, and the neutral point moves towards the distal end. As a result, the optimum length of fulllength grouted bolts can be determined by in-situ pull-out tests and decreases with the increased elastic modulus of the rock mass.