摘要
为了研究钢夹板—螺栓连接胶合木的抗剪性能,以东北落叶松胶合木—钢夹板螺栓连接件为研究对象,共设计12组(36个)钢夹板—螺栓连接胶合木进行剪切静载试验,结合理论分析和试验结果表明:材料规格和螺栓数目相同时,螺栓错列布置的抗剪能力明显高于并列布置;随着螺栓列数的增加,屈服荷载与极限荷载明显提高,且螺栓列数与剪切荷载呈非线性关系;在多螺栓连接件中,随着螺栓间距的增大,连接件的初始刚度与屈服后刚度呈减小趋势,极限荷载与屈服荷载呈增大趋势。
In order to study the shearing performance of steel splint-bolted glued wood, the paper designs 12 groups(36) steel splintbolted joint glued wood for shearing static load test with larch steel splint and bolted joint glued wood in northeastern China. Combined with theoretical analysis and experimental results, it is shown that the material specification and bolt number are simultaneously the shearing capacity of the bolt-column arrangement is obviously higher than that of the parallel arrangement; with the increase of bolt number, the yield load and the ultimate load are obviously improved, and the number of bolts is non-linear with the shear load. In the multi-bolt connection, with the increase of the bolt spacing, The initial stiffness and the stiffness of the joint are decreased, and the ultimate load and yield load are increasing.
作者
陈爱军
牛东
占雪芳
王解军
彭容新
姚嘉帅
CHEN Aijun;NIU Dong;ZHAN Xuefang;WANG Jiejun;PENG Rongxin;YAO Jiashuai(College of Civil Engineering,Central South University of Forestry and Technology,Changsha 410004,Hunan,China)
出处
《中南林业科技大学学报》
CAS
CSCD
北大核心
2018年第9期115-119,共5页
Journal of Central South University of Forestry & Technology
基金
国家国际科技合作专项项目(2014DFA53120)
现代木结构工程材制造及应用技术湖南省工程实验室开放基金项目(HELFMTS1705)
中南林业科技大学青年科学研究基金重点项目(QJ2012003A)
关键词
钢夹板-螺栓连接胶合木
抗剪性能
并、错列布置
螺栓间距
steel splint-bolted joint glued wood
shear behavior
arrangement of coordinate &stagger
bolt spacing