A water-conducting polyacrylamide/montmorillonite coating was prepared by solutionblending.The coating was coated on fiber and then composited with polymer to form a composite film material that used for water saving ...A water-conducting polyacrylamide/montmorillonite coating was prepared by solutionblending.The coating was coated on fiber and then composited with polymer to form a composite film material that used for water saving and tree planting in arid and desert regions.The coating's water-conducting characteristics and dynamic self-adjusting behavior were investigated by Fourier transform infrared(FTIR)spectroscopy,thermal analysis(TG-DTA),and environmental scanning electron microscopy(ESEM).The results showed that the coating's water-conducting rate increased but water-retention capacity weakened with increasing montmorillonite content.The water-loss rate was positively related to temperature and negatively related to soil moisture.Water potential greatly influenced the water-conducting rate of the coating during its water conduction process.When the coating was at a low water potential,the montmorillonite particles interconnected and water was conducted quickly via montmorillonite layers,whereas when the coating was at a high potential,the montmorillonite particles disconnected and water was conducted slowly via the swelled polyacrylamide net structure.The rate can be regulated by changing the proportion of polyacrylamide and montmorillonite to guarantee a reasonable water supply for trees and make trees easier to survive.Thus,the survival rate of trees can be increased and the use of water resources can be significantly reduced.展开更多
Impacts of climate warming on heating energy consumption and southern boundaries of severe cold and cold regions of China in the past 20 years are analyzed by using daily and monthly average tem- perature data from 59...Impacts of climate warming on heating energy consumption and southern boundaries of severe cold and cold regions of China in the past 20 years are analyzed by using daily and monthly average tem- perature data from 590 weather stations in China and based on regulations of Heating Ventilation and Air Conditioning Design Rules (GB50019-2003) and Thermal Design Rules for Civil Building (GB50175-93) (China National Standard). The contribution of climate warming to coal saving for heating during cold seasons in major cities is calculated according to indices of coal consumption for heating in major cities during cold seasons defined in Energy Conservation Design Standard for New Heating Residential Buildings (JCJ26-95). Comparing with the period before 1980, southern boundaries of se- vere cold and cold regions shift toward north up to 2 degrees in latitude since the mid-1980s. Theo- retically, climate warming could contribute to 5%―10% coal savings for heating since the mid-1980s in major cities, and even more since the mid-1990s.展开更多
基金Funded by the National Science Foundation of China(No.50772131)the National High-tech R&D Program of China(863Program)(No.2011AA322100)+1 种基金the Key Project of Chinese Ministry of Education(No.106086)the Fundmental Research Funds for the Central Universities(No.2010YJ05)
文摘A water-conducting polyacrylamide/montmorillonite coating was prepared by solutionblending.The coating was coated on fiber and then composited with polymer to form a composite film material that used for water saving and tree planting in arid and desert regions.The coating's water-conducting characteristics and dynamic self-adjusting behavior were investigated by Fourier transform infrared(FTIR)spectroscopy,thermal analysis(TG-DTA),and environmental scanning electron microscopy(ESEM).The results showed that the coating's water-conducting rate increased but water-retention capacity weakened with increasing montmorillonite content.The water-loss rate was positively related to temperature and negatively related to soil moisture.Water potential greatly influenced the water-conducting rate of the coating during its water conduction process.When the coating was at a low water potential,the montmorillonite particles interconnected and water was conducted quickly via montmorillonite layers,whereas when the coating was at a high potential,the montmorillonite particles disconnected and water was conducted slowly via the swelled polyacrylamide net structure.The rate can be regulated by changing the proportion of polyacrylamide and montmorillonite to guarantee a reasonable water supply for trees and make trees easier to survive.Thus,the survival rate of trees can be increased and the use of water resources can be significantly reduced.
基金Supported by "Climate Change Research Project", China Meteorological Admini-stration (Grant No. CCSF2007-43)
文摘Impacts of climate warming on heating energy consumption and southern boundaries of severe cold and cold regions of China in the past 20 years are analyzed by using daily and monthly average tem- perature data from 590 weather stations in China and based on regulations of Heating Ventilation and Air Conditioning Design Rules (GB50019-2003) and Thermal Design Rules for Civil Building (GB50175-93) (China National Standard). The contribution of climate warming to coal saving for heating during cold seasons in major cities is calculated according to indices of coal consumption for heating in major cities during cold seasons defined in Energy Conservation Design Standard for New Heating Residential Buildings (JCJ26-95). Comparing with the period before 1980, southern boundaries of se- vere cold and cold regions shift toward north up to 2 degrees in latitude since the mid-1980s. Theo- retically, climate warming could contribute to 5%―10% coal savings for heating since the mid-1980s in major cities, and even more since the mid-1990s.