A magnetic proton recoil (MPR) spectrometer is a novel instrument with superior performance, including high energy resolution, high count rate and good signal-to-noise ratio (SNR) for measurements of neutron spect...A magnetic proton recoil (MPR) spectrometer is a novel instrument with superior performance, including high energy resolution, high count rate and good signal-to-noise ratio (SNR) for measurements of neutron spectra from inertial confinement fusion (ICF) experiments and high power Tokomaks. In this work, the design of a compact MPR spectrometer (cMPR) was evaluated for deuteron-tritium (DT) neutron spectroscopy. The characteristics of the spectrometer were analyzed using 2-D beam transport simulations, 3-D particle transport calculations and Monte-Carlo simulations. Based on the theoretical results, an instrument design that satisfies special experimental requirements is proposed. The energy resolution and efficiency of the spectrometer are also evaluated. The results indicate that the proposed cMPR spectrometer would achieve a detection efficiency and energy resolution of approximately 10?8 and 4%, respectively, for DT neutrons.展开更多
The magnetic proton recoil(MPR)spectrometer is a novel diagnostic instrument with high perfor-mance for measurements of neutron spectra in inertial confinement fusion(ICF)experiments and high power fusion devices....The magnetic proton recoil(MPR)spectrometer is a novel diagnostic instrument with high perfor-mance for measurements of neutron spectra in inertial confinement fusion(ICF)experiments and high power fusion devices.A compact MPR-type spectrometer dedicated to the research of pulsed deuterium-tritium(DT)neutron spectroscopy of special experimental conditions is currently under design.Analyses of the main parameters and performance of the magnetic analysis system through 3-D particle transport calculations and MonteCarlo simulations and calibration of the system performance as a test using CR-39 solid track detector and α particle from 239pu and 226Ra radioactive sources are presented in this paper.The results indicate that the magnetic analysis system will achieve a detection efficiency level of 10-5-10-4 at an energy resolution of 1.5%-2.1%,and fulfills the design goals of the spectrometer.展开更多
The neutron response function and detection efficiency of a spherical proton recoil proportional counter (SP) play key roles in precise measurement of neutron spectra of the interior materials.In this paper,the respon...The neutron response function and detection efficiency of a spherical proton recoil proportional counter (SP) play key roles in precise measurement of neutron spectra of the interior materials.In this paper,the response functions and detection efficiency of three SPs developed at CAEP are simulated by Geant4.The simulated spectra are compared with pulse-height spectra measured at 0.165,0.575,1.4,and 14.1 MeV of incident neutrons.And the calculated detector efficiencies agree within 5%with the data obtained by neutron activation.展开更多
Filtered neutron technique was applied for producing quasi-monoenergetic neutron beams of 24 keV, 54 keV, 133 keV and 148 keV at the horizontal neutron channel No. 4 of the Dalat Nuclear Research Reactor. The study on...Filtered neutron technique was applied for producing quasi-monoenergetic neutron beams of 24 keV, 54 keV, 133 keV and 148 keV at the horizontal neutron channel No. 4 of the Dalat Nuclear Research Reactor. The study on physical characteristics of these beam lines has been carried out for efficient applications in neutron capture experiments. The filtered neutron spectrum of each beam has been simulated by Monte-Carlo method and experimentally measured by a gas-filled protonrecoil spectrometer. The neutron fluxes of these filtered beams were measured by the activation technique with standard foils of 197Au, using a high efficient HPGe digital gamma-ray spectrometer.展开更多
基金Supported by Science and Technology Development Foundation of China Academy of Engineering Physics (2008B0103003)
文摘A magnetic proton recoil (MPR) spectrometer is a novel instrument with superior performance, including high energy resolution, high count rate and good signal-to-noise ratio (SNR) for measurements of neutron spectra from inertial confinement fusion (ICF) experiments and high power Tokomaks. In this work, the design of a compact MPR spectrometer (cMPR) was evaluated for deuteron-tritium (DT) neutron spectroscopy. The characteristics of the spectrometer were analyzed using 2-D beam transport simulations, 3-D particle transport calculations and Monte-Carlo simulations. Based on the theoretical results, an instrument design that satisfies special experimental requirements is proposed. The energy resolution and efficiency of the spectrometer are also evaluated. The results indicate that the proposed cMPR spectrometer would achieve a detection efficiency and energy resolution of approximately 10?8 and 4%, respectively, for DT neutrons.
基金Supported by Science and Technology Development Foundation of China Academy of Engineering Physics (2008B0103003)
文摘The magnetic proton recoil(MPR)spectrometer is a novel diagnostic instrument with high perfor-mance for measurements of neutron spectra in inertial confinement fusion(ICF)experiments and high power fusion devices.A compact MPR-type spectrometer dedicated to the research of pulsed deuterium-tritium(DT)neutron spectroscopy of special experimental conditions is currently under design.Analyses of the main parameters and performance of the magnetic analysis system through 3-D particle transport calculations and MonteCarlo simulations and calibration of the system performance as a test using CR-39 solid track detector and α particle from 239pu and 226Ra radioactive sources are presented in this paper.The results indicate that the magnetic analysis system will achieve a detection efficiency level of 10-5-10-4 at an energy resolution of 1.5%-2.1%,and fulfills the design goals of the spectrometer.
文摘The neutron response function and detection efficiency of a spherical proton recoil proportional counter (SP) play key roles in precise measurement of neutron spectra of the interior materials.In this paper,the response functions and detection efficiency of three SPs developed at CAEP are simulated by Geant4.The simulated spectra are compared with pulse-height spectra measured at 0.165,0.575,1.4,and 14.1 MeV of incident neutrons.And the calculated detector efficiencies agree within 5%with the data obtained by neutron activation.
文摘Filtered neutron technique was applied for producing quasi-monoenergetic neutron beams of 24 keV, 54 keV, 133 keV and 148 keV at the horizontal neutron channel No. 4 of the Dalat Nuclear Research Reactor. The study on physical characteristics of these beam lines has been carried out for efficient applications in neutron capture experiments. The filtered neutron spectrum of each beam has been simulated by Monte-Carlo method and experimentally measured by a gas-filled protonrecoil spectrometer. The neutron fluxes of these filtered beams were measured by the activation technique with standard foils of 197Au, using a high efficient HPGe digital gamma-ray spectrometer.