紧凑型磁质子反冲谱仪磁分析系统的能量刻度

Energy Calibration of Magnetic Analysis System for Compact Magnetic Proton Recoil Spectrometer
下载PDF
导出
摘要 介绍了一种用于多种特定环境下脉冲氘氚聚变中子能谱测量的紧凑型磁质子反冲谱仪的磁分析系统。通过三维粒子输运和蒙特卡罗模拟对磁分析系统性能进行了分析,使用CR-39径迹探测器和多个能量α单能粒子对系统进行了能量刻度。结果表明,磁分析系统具有良好的能量离散与聚焦性能,对给定能量范围的反冲质子,能够以1.5%~2.1%的能量分辨率实现(0.5~1.4)×10-4的探测效率。 A magnetic analysis system for a compact magnetic proton recoil spectrometer dedicated to pulse DT neutron spectroscopy in special experimental environments was presented.Performance of the system was analyzed using 3-D particle transport calculation and Monte-Carlo simulation.Energy calibration of the system was obtained using CR-39 track detector and mono-energetic α particles.The results indicate that the magnetic analysis system has achieved satisfactory performance on energy dispersion and focusing.It can achieve a detection efficiency of approximately(0.5-1.4)×10-4 with an energy resolution from 1.5% to 2.1%(for 7 MeV protons) in a given energy range of recoil protons.
出处 《原子能科学技术》 EI CAS CSCD 北大核心 2011年第7期880-883,共4页 Atomic Energy Science and Technology
基金 中国工程物理研究院科学技术发展基金资助项目(2008B0103003)
关键词 聚变中子 磁质子反冲 能量刻度 CR-39 fusion neutron magnetic proton recoil energy calibration CR-39
  • 相关文献

参考文献9

  • 1JARVIS O N. Neutron spectrometry at JET (1983—1999)[J]. Nucl Instrum Methods A, 2002, 476: 474-484. 被引量:1
  • 2K LLNE J, BALLABIO L, CONROY S, et al. New neutron diagnostics with the magnetic proton recoil spectrometer[J]. Rev Sci Instrum, 1999, 70(1): 1 181-1 184. 被引量:1
  • 3AYMAR R. Review status of ITER[J]. Fusion Engineering and Design, 2002, 61-62: 5-12. 被引量:1
  • 4SJ STRAND H, GORINI G, MURARI A, et al. New MPRu instrument for neutron emission spectroscopy at JET[J]. Rev Sci Instrum, 2006, 77: 10E717. 被引量:1
  • 5MAAS C A, ANDREW P, COAD P, et al. Diagnostic experience during deuterium-tritium experiments in JET, techniques and measurements[J]. Fusion Eng Des, 1999, 47: 247-265. 被引量:1
  • 6FRENJE J, BALLABIO L, CONROY S, et al. Neutron emission Doppler-shift measurements in deuterium-tritium plasmas[J]. Rev Sci Instrum, 1999, 70(1): 1 176-1 180. 被引量:1
  • 7FRENJE J, SANGSTER C T, GLEBOV Y V, et al. A neutron spectrometer for precise measurements of DT neutrons from 10 to 18 MeV at OMEGA and the National Ignition Facility[J]. Rev Sci Instrum, 2001, 72(1): 854-858. 被引量:1
  • 8GLEBOV Y V, BARRERA A C, CALDWELL E S, et al. Development of nuclear diagnostics for the national ignition facility (invited)[J]. Rev Sci Instrum, 2006, 77: 10E715. 被引量:1
  • 9ROHRER U. PSI graphic transport framework based on a CERN-SLAC-FERMILAB[EB/OL]. (2000). http:∥people.web.psi.ch/rohrer_u/trans.htm. 被引量:1