With the advent of the 5G era and the rise of the Internet of Things,various sensors have received unprecedented attention,especially wearable and stretchable sensors in the healthcare field.Here,a stretchable,self-he...With the advent of the 5G era and the rise of the Internet of Things,various sensors have received unprecedented attention,especially wearable and stretchable sensors in the healthcare field.Here,a stretchable,self-healable,self-adhesive,and room-temperature oxygen sensor with excellent repeatability,a full concentration detection range(0-100%),low theoretical limit of detection(5.7 ppm),high sensitivity(0.2%/ppm),good linearity,excellent temperature,and humidity tolerances is fabricated by using polyacrylamide-chitosan(PAM-CS)double network(DN)organohydrogel as a novel transducing material.The PAM-CS DN organohydrogel is transformed from the PAM-CS composite hydrogel using a facile soaking and solvent replacement strategy.Compared with the pristine hydrogel,the DN organohydrogel displays greatly enhanced mechanical strength,moisture retention,freezing resistance,and sensitivity to oxygen.Notably,applying the tensile strain improves both the sensitivity and response speed of the organohydrogel-based oxygen sensor.Furthermore,the response to the same concentration of oxygen before and after self-healing is basically the same.Importantly,we propose an electrochemical reaction mechanism to explain the positive current shift of the oxygen sensor and corroborate this sensing mechanism through rationally designed experiments.The organohydrogel oxygen sensor is used to monitor human respiration in real-time,verifying the feasibility of its practical application.This work provides ideas for fabricating more stretchable,self-healable,self-adhesive,and high-performance gas sensors using ion-conducting organohydrogels.展开更多
Oxygen(O_(2))-sensing matrices are promising tools for the live monitoring of extracellular O_(2) consumption levels in long-term cell cultures.In this study,ratiometric O_(2)-sensing membranes were prepared by electr...Oxygen(O_(2))-sensing matrices are promising tools for the live monitoring of extracellular O_(2) consumption levels in long-term cell cultures.In this study,ratiometric O_(2)-sensing membranes were prepared by electrospinning,an easy,low-cost,scalable,and robust method for fabricating nanofibers.Poly(ε-caprolactone)and poly(dimethyl)siloxane polymers were blended with tris(4,7-diphenyl-1,10-phenanthroline)ruthenium(II)dichloride,which was used as the O_(2)-sensing probe,and rhodamine B isothiocyanate,which was used as the reference dye.The functionalized scaffolds were morphologically characterized by scanning electron microscopy,and their physicochemical profiles were obtained by Fourier transform infrared spectroscopy,thermogravimetric analysis,and water contact angle measurement.The sensing capabilities were investigated by confocal laser scanning microscopy,performing photobleaching,reversibility,and calibration curve studies toward different dissolved O_(2)(DO)concentrations.Electrospun sensing nanofibers showed a high response to changes in DO concentrations in the physiological-pathological range from 0.5%to 20%and good stability under ratiometric imaging.In addition,the sensing systems were highly biocompatible for cell growth promoting adhesiveness and growth of three cancer cell lines,namely metastatic melanoma cell line SK-MEL2,breast cancer cell line MCF-7,and pancreatic ductal adenocarcinoma cell line Panc-1,thus recreating a suitable biological environment in vitro.These O_(2)-sensing biomaterials can potentially measure alterations in cell metabolism caused by changes in ambient O_(2)content during drug testing/validation and tissue regeneration processes.展开更多
A dissolved oxygen (DO) sensor based on U-shape plastic optical fiber (POF) and dichlorotris (1, 10- phenanthroline) ruthenium ([Ru(dpp)^3]^2+) as an oxygen indicator was described. Fluorescence intensity a...A dissolved oxygen (DO) sensor based on U-shape plastic optical fiber (POF) and dichlorotris (1, 10- phenanthroline) ruthenium ([Ru(dpp)^3]^2+) as an oxygen indicator was described. Fluorescence intensity and lifetime were measured when the sensor was soaked into a water bath blasted with air with varied O2/N2 ratios. The influence of Ru concentration, annealing time and U-shaped POF curve radius on the system sensitivity was also studied. A two-layer model was proposed to analyze the deviation from linear relation described by Stern-Volmer equation, and to explain the deviation and the dependence of the fluorescence on curvature of U-shape POF. By fitting the experimentally measured sub-linear relation of τ0/τ ratio versus oxygen concentration, the proportion of effectively sensitive layer and the Stern-Volmer coefficient can be evaluated to be f = 0.59 and Ksv = 0.61 typically.展开更多
基金support from the National Natural Science Foundation of China(61801525)the Guangdong Basic and Applied Basic Research Foundation(2020A1515010693)+1 种基金the Guangdong Natural Science Funds Grant(2018A030313400),the Science and Technology Program of Guangzhou(201904010456)the Fundamental Research Funds for the Central Universities,Sun Yat-sen University(2021qntd09).
文摘With the advent of the 5G era and the rise of the Internet of Things,various sensors have received unprecedented attention,especially wearable and stretchable sensors in the healthcare field.Here,a stretchable,self-healable,self-adhesive,and room-temperature oxygen sensor with excellent repeatability,a full concentration detection range(0-100%),low theoretical limit of detection(5.7 ppm),high sensitivity(0.2%/ppm),good linearity,excellent temperature,and humidity tolerances is fabricated by using polyacrylamide-chitosan(PAM-CS)double network(DN)organohydrogel as a novel transducing material.The PAM-CS DN organohydrogel is transformed from the PAM-CS composite hydrogel using a facile soaking and solvent replacement strategy.Compared with the pristine hydrogel,the DN organohydrogel displays greatly enhanced mechanical strength,moisture retention,freezing resistance,and sensitivity to oxygen.Notably,applying the tensile strain improves both the sensitivity and response speed of the organohydrogel-based oxygen sensor.Furthermore,the response to the same concentration of oxygen before and after self-healing is basically the same.Importantly,we propose an electrochemical reaction mechanism to explain the positive current shift of the oxygen sensor and corroborate this sensing mechanism through rationally designed experiments.The organohydrogel oxygen sensor is used to monitor human respiration in real-time,verifying the feasibility of its practical application.This work provides ideas for fabricating more stretchable,self-healable,self-adhesive,and high-performance gas sensors using ion-conducting organohydrogels.
基金funding from the European Research Council (ERC) under the European Union’s (EU’s) Horizon 2020 research and innovation program ERC Starting Grant “INTERCELLMED” (No. 759959)the EU’s Horizon 2020 research and innovation program under grant agreement No. 953121 (FLAMIN-GO)+7 种基金the Associazione Italiana per la Ricerca contro il Cancro (AIRCMFAG-2019No. 22902)the “Tecnopolo per la medicina di precisione” (Tecno Med Puglia)-Regione Puglia: DGR n.2117 of 21/11/2018, B84I18000540002the Italian Ministry of Research (MUR) in the framework of the National Recovery and Resilience Plan (NRRP), “NFFA-DI” Grant (n. B53C22004310006), “I-PHOQS” Grant (n. B53C22001750006) and under the complementary actions to the NRRP, “Fit4MedRob” Grant (PNC0000007, n. B53C22006960001), “ANTHEM” Grant (PNC0000003, n. B53C22006710001), funded by Next Generation EUthe PRIN 2022 (2022CRFNCP_PE11_PRIN2022) funded by European Union-Next Generation EUthe financial support provided under the project “HEALTH-UNORTE: Setting-up biobanks and regenerative medicine strategies to boost research in cardiovascular, musculoskeletal, neurological, oncological, immunological, and infectious diseases” (reference NORTE-01-0145FEDER-000039) funded by the Norte Portugal Regional Coordination and Development Commission (CCDR-N) under the NORTE2020 Programthe AIRC Short-term Fellowship program
文摘Oxygen(O_(2))-sensing matrices are promising tools for the live monitoring of extracellular O_(2) consumption levels in long-term cell cultures.In this study,ratiometric O_(2)-sensing membranes were prepared by electrospinning,an easy,low-cost,scalable,and robust method for fabricating nanofibers.Poly(ε-caprolactone)and poly(dimethyl)siloxane polymers were blended with tris(4,7-diphenyl-1,10-phenanthroline)ruthenium(II)dichloride,which was used as the O_(2)-sensing probe,and rhodamine B isothiocyanate,which was used as the reference dye.The functionalized scaffolds were morphologically characterized by scanning electron microscopy,and their physicochemical profiles were obtained by Fourier transform infrared spectroscopy,thermogravimetric analysis,and water contact angle measurement.The sensing capabilities were investigated by confocal laser scanning microscopy,performing photobleaching,reversibility,and calibration curve studies toward different dissolved O_(2)(DO)concentrations.Electrospun sensing nanofibers showed a high response to changes in DO concentrations in the physiological-pathological range from 0.5%to 20%and good stability under ratiometric imaging.In addition,the sensing systems were highly biocompatible for cell growth promoting adhesiveness and growth of three cancer cell lines,namely metastatic melanoma cell line SK-MEL2,breast cancer cell line MCF-7,and pancreatic ductal adenocarcinoma cell line Panc-1,thus recreating a suitable biological environment in vitro.These O_(2)-sensing biomaterials can potentially measure alterations in cell metabolism caused by changes in ambient O_(2)content during drug testing/validation and tissue regeneration processes.
基金the Foundation of Shanghai Technology Committee under Grant No.061458037
文摘A dissolved oxygen (DO) sensor based on U-shape plastic optical fiber (POF) and dichlorotris (1, 10- phenanthroline) ruthenium ([Ru(dpp)^3]^2+) as an oxygen indicator was described. Fluorescence intensity and lifetime were measured when the sensor was soaked into a water bath blasted with air with varied O2/N2 ratios. The influence of Ru concentration, annealing time and U-shaped POF curve radius on the system sensitivity was also studied. A two-layer model was proposed to analyze the deviation from linear relation described by Stern-Volmer equation, and to explain the deviation and the dependence of the fluorescence on curvature of U-shape POF. By fitting the experimentally measured sub-linear relation of τ0/τ ratio versus oxygen concentration, the proportion of effectively sensitive layer and the Stern-Volmer coefficient can be evaluated to be f = 0.59 and Ksv = 0.61 typically.