When better fuel-air mixing in the combustion chamber or a reduction in base drag are required in vehicles,rockets,and aeroplanes,the base pressure control is activated.Controlling the base pressure and drag is necess...When better fuel-air mixing in the combustion chamber or a reduction in base drag are required in vehicles,rockets,and aeroplanes,the base pressure control is activated.Controlling the base pressure and drag is necessary in both scenarios.In this work,semi-circular ribs with varying diameters(2,4,and 6 mm)positioned at six distinct positions(0.5D,1D,1.5D,2D,3D,and 4D)inside a square duct with a side of 15 mm are proposed as an efficient way to apply the passive control technique.In-depth research is done on optimising rib size for various rib sites.According to this study,the base pressure rises as rib height increases.Furthermore,the optimal location for the semi-circular ribs with a diameter of 2 mm is at 0.5D.The 1D location appears to be optimal for the 4 mm size as well.For the 6 mm size,however,the 4D position fills this function.展开更多
Many researches on critical nozzles have been performed to accurately measure the mass flow rate of gas flow,and to standardize the performance as a flow meter.Recently,much interest is being paid on the measurement o...Many researches on critical nozzles have been performed to accurately measure the mass flow rate of gas flow,and to standardize the performance as a flow meter.Recently,much interest is being paid on the measurement of very small mass flow rate in industry fields such as MEMS applications.However,the design and performance data of the critical nozzles obtained so far have been applied mainly to the critical nozzles with comparatively large diameters,and the works available on miniature critical nozzles are lacking.In the present study,a computational fluid dynamics method has been applied to investigate the influence of the diffuser angle on discharge coefficient of the miniature critical nozzles.In computations,the throat diameter of critical nozzle is varied from 0.2 mm to 5.0 mm and the diffuser angle is changed from 2 deg to 8 deg.The computational results are validated with some experimental data available.The results show that the present computational results predict appropriately the discharge coefficient of the gas flows through miniature critical nozzles.It is known that the discharge coefficient is considerably influenced by the diffuser angle,as the throat diameter of nozzle becomes small below a certain value.This implies that the miniature critical nozzles should be carefully designed.展开更多
In this study, finite element analysis (FEA) has been used to investigate the effects of different Laval nozzle throat sizes on supersonic molecular beam. The simulations indicate the Mach numbers of the molecular s...In this study, finite element analysis (FEA) has been used to investigate the effects of different Laval nozzle throat sizes on supersonic molecular beam. The simulations indicate the Mach numbers of the molecular stream peak at different positions along the center axis of the beam, which correspond to local minimums of the molecular densities. With the increase of the throat diameter, the first peak of the Mach number increases first and then decreases, while that of the molecular number density increases gradually. Moreover, both first peaks shift progressively away from the throat. At the last part, we discuss the possible applications of our FEA approach to solve some crucial problems met in modern transportations.展开更多
基金supported by the Structures and Materials(S&M)Research Lab of Prince Sultan Universitysupport of Prince Sultan University in paying the article processing charges(APC)for this publication.
文摘When better fuel-air mixing in the combustion chamber or a reduction in base drag are required in vehicles,rockets,and aeroplanes,the base pressure control is activated.Controlling the base pressure and drag is necessary in both scenarios.In this work,semi-circular ribs with varying diameters(2,4,and 6 mm)positioned at six distinct positions(0.5D,1D,1.5D,2D,3D,and 4D)inside a square duct with a side of 15 mm are proposed as an efficient way to apply the passive control technique.In-depth research is done on optimising rib size for various rib sites.According to this study,the base pressure rises as rib height increases.Furthermore,the optimal location for the semi-circular ribs with a diameter of 2 mm is at 0.5D.The 1D location appears to be optimal for the 4 mm size as well.For the 6 mm size,however,the 4D position fills this function.
文摘Many researches on critical nozzles have been performed to accurately measure the mass flow rate of gas flow,and to standardize the performance as a flow meter.Recently,much interest is being paid on the measurement of very small mass flow rate in industry fields such as MEMS applications.However,the design and performance data of the critical nozzles obtained so far have been applied mainly to the critical nozzles with comparatively large diameters,and the works available on miniature critical nozzles are lacking.In the present study,a computational fluid dynamics method has been applied to investigate the influence of the diffuser angle on discharge coefficient of the miniature critical nozzles.In computations,the throat diameter of critical nozzle is varied from 0.2 mm to 5.0 mm and the diffuser angle is changed from 2 deg to 8 deg.The computational results are validated with some experimental data available.The results show that the present computational results predict appropriately the discharge coefficient of the gas flows through miniature critical nozzles.It is known that the discharge coefficient is considerably influenced by the diffuser angle,as the throat diameter of nozzle becomes small below a certain value.This implies that the miniature critical nozzles should be carefully designed.
基金financially supported by the Science Foundation for International Cooperation of Sichuan Province (2014HH0016)the Fundamental Research Funds for the Central Universities (SWJTU2014: A0920502051113-10000)National Magnetic Confinement Fusion Science Program (2011GB112001)
文摘In this study, finite element analysis (FEA) has been used to investigate the effects of different Laval nozzle throat sizes on supersonic molecular beam. The simulations indicate the Mach numbers of the molecular stream peak at different positions along the center axis of the beam, which correspond to local minimums of the molecular densities. With the increase of the throat diameter, the first peak of the Mach number increases first and then decreases, while that of the molecular number density increases gradually. Moreover, both first peaks shift progressively away from the throat. At the last part, we discuss the possible applications of our FEA approach to solve some crucial problems met in modern transportations.