In this paper,a new approach of meander line technique for Printed Quadrifilar Helix Antenna(PQHA) is studied.Compared with other meander line techniques,this approach has lowered the axial height of antenna greatly a...In this paper,a new approach of meander line technique for Printed Quadrifilar Helix Antenna(PQHA) is studied.Compared with other meander line techniques,this approach has lowered the axial height of antenna greatly and improved the efficiency of model-building in simulation processing.We have focused on the analysis of radiation pattern,axial ratio,and design graph for the Meander line Printed Quadrifilar Helix Antenna(MPQHA).Finally,we have reduced successfully 67% size in geometry compared with traditional PQHA method,and obtained rather reasonable results.展开更多
提出了一种工作在X波段的宽带慢波延迟线设计方法,介绍了慢波延迟线的基本概念,利用电磁仿真软件优化枝节的长度、间距、线宽及弯角的布局,实现小型化结构,提高宽带性能。仿真分析和实验结果表明:对比传统走线形式,最终获得蛇形慢波延...提出了一种工作在X波段的宽带慢波延迟线设计方法,介绍了慢波延迟线的基本概念,利用电磁仿真软件优化枝节的长度、间距、线宽及弯角的布局,实现小型化结构,提高宽带性能。仿真分析和实验结果表明:对比传统走线形式,最终获得蛇形慢波延迟线的延时效率达到200%,端口反射系数<-25 d B,带内相位线性度<8°。展开更多
Alzheimer’s disease (AD) is a brain disorder that eventually causes memory loss and the ability to perform simple cognitive functions;research efforts within pharmaceuticals and other medical treatments have minimal ...Alzheimer’s disease (AD) is a brain disorder that eventually causes memory loss and the ability to perform simple cognitive functions;research efforts within pharmaceuticals and other medical treatments have minimal impact on the disease. Our preliminary biological studies showed that Repeated Electromagnetic Field Stimulation (REFMS) applying an EM frequency of 64 MHz and a specific absorption rate (SAR) of 0.4 - 0.9 W/kg decrease the level of amyloid-β peptides (Aβ), which is the most likely etiology of AD. This study emphasizes uniform E/H field and SAR distribution with adequate penetration depth penetration through multiple human head layers driven with low input power for safety treatments. In this work, we performed numerical modeling and computer simulations of a portable Meander Line antenna (MLA) to achieve the required EMF parameters to treat AD. The MLA device features a low cost, small size, wide bandwidth, and the ability to integrate into a portable system. This study utilized a High-Frequency Simulation System (HFSS) in the design of the MLA with the desired characteristics suited for AD treatment in humans. The team designed a 24-turn antenna with a 60 cm length and 25 cm width and achieved the required resonant frequency of 64 MHz. Here we used two numerical human head phantoms to test the antenna, the MIDA and spherical head phantom with six and seven tissue layers, respectively. The antenna was fed from a 50-Watt input source to obtain the SAR of 0.6 W/kg requirement in the center of the simulated brain tissue layer. We found that the E/H field and SAR distribution produced was not homogeneous;there were areas of high SAR values close to the antenna transmitter, also areas of low SAR value far away from the antenna. This paper details the antenna parameters, the scattering parameters response, the efficiency response, and the E and H field distribution;we presented the computer simulation results and discussed future work for a practical model.展开更多
Meander line antenna has been considered desirable on flight vehicles to reduce drag and minimize aerodynamic disturbance;however, the antenna design and performance analysis have made mostly by trial-and-error. An in...Meander line antenna has been considered desirable on flight vehicles to reduce drag and minimize aerodynamic disturbance;however, the antenna design and performance analysis have made mostly by trial-and-error. An inductor model by simulating the meander line sections as electrical inductors and the interconnecting radiation elements as a quasi-monopole antenna is developed to analyze the antenna performance. Experimental verifications of the printed meander line antennas embedded in composite laminated substrates show that the inductor model is effective to design and analyze. Of the 4 antennas tested, the discrepancy of resonant frequency in simulation and experiment is within 4.6%.展开更多
文摘In this paper,a new approach of meander line technique for Printed Quadrifilar Helix Antenna(PQHA) is studied.Compared with other meander line techniques,this approach has lowered the axial height of antenna greatly and improved the efficiency of model-building in simulation processing.We have focused on the analysis of radiation pattern,axial ratio,and design graph for the Meander line Printed Quadrifilar Helix Antenna(MPQHA).Finally,we have reduced successfully 67% size in geometry compared with traditional PQHA method,and obtained rather reasonable results.
文摘提出了一种工作在X波段的宽带慢波延迟线设计方法,介绍了慢波延迟线的基本概念,利用电磁仿真软件优化枝节的长度、间距、线宽及弯角的布局,实现小型化结构,提高宽带性能。仿真分析和实验结果表明:对比传统走线形式,最终获得蛇形慢波延迟线的延时效率达到200%,端口反射系数<-25 d B,带内相位线性度<8°。
文摘Alzheimer’s disease (AD) is a brain disorder that eventually causes memory loss and the ability to perform simple cognitive functions;research efforts within pharmaceuticals and other medical treatments have minimal impact on the disease. Our preliminary biological studies showed that Repeated Electromagnetic Field Stimulation (REFMS) applying an EM frequency of 64 MHz and a specific absorption rate (SAR) of 0.4 - 0.9 W/kg decrease the level of amyloid-β peptides (Aβ), which is the most likely etiology of AD. This study emphasizes uniform E/H field and SAR distribution with adequate penetration depth penetration through multiple human head layers driven with low input power for safety treatments. In this work, we performed numerical modeling and computer simulations of a portable Meander Line antenna (MLA) to achieve the required EMF parameters to treat AD. The MLA device features a low cost, small size, wide bandwidth, and the ability to integrate into a portable system. This study utilized a High-Frequency Simulation System (HFSS) in the design of the MLA with the desired characteristics suited for AD treatment in humans. The team designed a 24-turn antenna with a 60 cm length and 25 cm width and achieved the required resonant frequency of 64 MHz. Here we used two numerical human head phantoms to test the antenna, the MIDA and spherical head phantom with six and seven tissue layers, respectively. The antenna was fed from a 50-Watt input source to obtain the SAR of 0.6 W/kg requirement in the center of the simulated brain tissue layer. We found that the E/H field and SAR distribution produced was not homogeneous;there were areas of high SAR values close to the antenna transmitter, also areas of low SAR value far away from the antenna. This paper details the antenna parameters, the scattering parameters response, the efficiency response, and the E and H field distribution;we presented the computer simulation results and discussed future work for a practical model.
基金Supported by the National Program on Key Basic Research Project of China(613233)the National Natural Science Foundation of China(61771117,61531010,61271029)
文摘提出了一种基于开槽介质基底的卷绕微带线慢波结构.由于金属曲折微带线印制在介质基底的半圆形槽中,这种卷绕微带线慢波结构非常适合圆形电子注行波管,从而使得采用这种新型慢波结构的行波管可以利用传统的周期永磁磁场进行聚焦.文章对提出的卷绕微带线慢波结构的色散特性,耦合阻抗,传输特性及注-波互作用进行了分析.和传统的平面微带线慢波结构相比,提出的卷绕微带线慢波结构具有更低的相速、更弱的色散和更高的耦合阻抗,从而使得其适合于低电压、宽频带、小型化的毫米波行波管.将同步电压及直流电流分别设置为6 550 V及0.1 A的情况下,基于该卷绕微带线慢波结构的Ka波段行波管在35 GHz处能够输出42.32 W的功率,对应增益为26.26 dB,且均匀聚焦磁场只需0.4 T.
文摘Meander line antenna has been considered desirable on flight vehicles to reduce drag and minimize aerodynamic disturbance;however, the antenna design and performance analysis have made mostly by trial-and-error. An inductor model by simulating the meander line sections as electrical inductors and the interconnecting radiation elements as a quasi-monopole antenna is developed to analyze the antenna performance. Experimental verifications of the printed meander line antennas embedded in composite laminated substrates show that the inductor model is effective to design and analyze. Of the 4 antennas tested, the discrepancy of resonant frequency in simulation and experiment is within 4.6%.