信号检测是激光多普勒测速(LDV)系统实现高精度的关键技术,针对LDV中微弱多普勒信号的检测,本文从噪声在频域中的统计特性出发,对多普勒信号进行带阻滤波,结合雷达的恒虚警(CFAR)检测技术,设计了基于频域的单元平方和自适应阈值检测算...信号检测是激光多普勒测速(LDV)系统实现高精度的关键技术,针对LDV中微弱多普勒信号的检测,本文从噪声在频域中的统计特性出发,对多普勒信号进行带阻滤波,结合雷达的恒虚警(CFAR)检测技术,设计了基于频域的单元平方和自适应阈值检测算法以解决在低信噪比(SNR)的环境中LDV的信号检测问题,提高LDV的信号探测能力,同时降低其虚警概率。仿真与实验的结果表明:该算法与固定阈值相比可以在SNR为-12 d B时实现信号的完全检测,保持低虚警概率,运算简单,工程适用性强。展开更多
Ubiquitous radar is a new radar system that provides continuous and uninterrupted multifunction capability within a coverage volume. Continuous coverage from close-in "pop-up" targets in clutter to long-range target...Ubiquitous radar is a new radar system that provides continuous and uninterrupted multifunction capability within a coverage volume. Continuous coverage from close-in "pop-up" targets in clutter to long-range targets impacts selection of waveform parameters. The coherent processing interval (CPI) must be long enough to achieve a certain signal-to-noise ratio (SNR) that ensures the efficiency of detection. The condition of detection in the case of low SNR is analyzed, and three different cases that would occur during integration are discussed and a method to determine the CPI is presented. The simulation results show that targets detection with SNR as low as -26 dB in the experimental system can possibly determine the CPI.展开更多
基于分数阶傅里叶变换(Fractional Fourier Transform,FRFT)对线性调频(Linear Frequency Modulated,LFM)信号参数进行估计,问题关键是确定FRFT最佳阶数,根据误差迭代思想提出新的参数估计算法,该算法利用归一化带宽和旋转角的转化关系...基于分数阶傅里叶变换(Fractional Fourier Transform,FRFT)对线性调频(Linear Frequency Modulated,LFM)信号参数进行估计,问题关键是确定FRFT最佳阶数,根据误差迭代思想提出新的参数估计算法,该算法利用归一化带宽和旋转角的转化关系,由估计误差推算角度差值,有效降低了运算量,不需要调频斜率正负的先验信息,改进的对数搜索算法可以进一步提高参数估计结果的稳定性和可靠性。仿真结果表明,信噪比在-8 dB以上时该方法在高效率的前提下仍具有良好的参数估计性能,平均估计误差在1%以内,估计结果接近Cramer-Rao下限,满足工程实时处理需求。展开更多
文摘信号检测是激光多普勒测速(LDV)系统实现高精度的关键技术,针对LDV中微弱多普勒信号的检测,本文从噪声在频域中的统计特性出发,对多普勒信号进行带阻滤波,结合雷达的恒虚警(CFAR)检测技术,设计了基于频域的单元平方和自适应阈值检测算法以解决在低信噪比(SNR)的环境中LDV的信号检测问题,提高LDV的信号探测能力,同时降低其虚警概率。仿真与实验的结果表明:该算法与固定阈值相比可以在SNR为-12 d B时实现信号的完全检测,保持低虚警概率,运算简单,工程适用性强。
文摘Ubiquitous radar is a new radar system that provides continuous and uninterrupted multifunction capability within a coverage volume. Continuous coverage from close-in "pop-up" targets in clutter to long-range targets impacts selection of waveform parameters. The coherent processing interval (CPI) must be long enough to achieve a certain signal-to-noise ratio (SNR) that ensures the efficiency of detection. The condition of detection in the case of low SNR is analyzed, and three different cases that would occur during integration are discussed and a method to determine the CPI is presented. The simulation results show that targets detection with SNR as low as -26 dB in the experimental system can possibly determine the CPI.