The Isochronous Mass Spectrometry is a high accurate mass spectrometer. A secondary electrons time detector has been developed and used for mass measurements. Secondary electrons from a thin carbon foil are accelerate...The Isochronous Mass Spectrometry is a high accurate mass spectrometer. A secondary electrons time detector has been developed and used for mass measurements. Secondary electrons from a thin carbon foil are accelerated by an electric field and deflected 180°by a magnetic field onto a micro-channel plate. The time detector has been tested with alpha particles and a time resolution of 197 ps (FWHM) was obtained in the laboratory. A mass resolution around 8×10^-6 for Am/m was achieved by using this time detector in a pilot mass measurement experiment.展开更多
In this work, a parametric approach is presented and utilized to determine the creep properties of weldments; then the model of creep strain for cross weld specimen is given. On the basis of the experimental results, ...In this work, a parametric approach is presented and utilized to determine the creep properties of weldments; then the model of creep strain for cross weld specimen is given. On the basis of the experimental results, attempt has been made to establish equations of the isochronous stress-strain for weld joint that can predict the function of loading and service time in use of the creep data of base metal and weld metal.展开更多
This paper studies the global phase portraits of uniform isochronous centers system of degree six with polynomial commutator.Such systems have the form x=-y+xf(x,y),y=x+yf(x,y),where f(x,y)=a_(1)x+a_(2)xy+a_(3)xy^(2)+...This paper studies the global phase portraits of uniform isochronous centers system of degree six with polynomial commutator.Such systems have the form x=-y+xf(x,y),y=x+yf(x,y),where f(x,y)=a_(1)x+a_(2)xy+a_(3)xy^(2)+a_(4)xy^(3)+a_(5)xy^(4)=xσ(y),and any zero of 1+a_(1)y+a_(2)y^(2)+a_(3)y^(3)+a_(4)y^(4)+a_(5)y^(5),y=y is an invariant straight line.At last,all global phase portraits are drawn on the Poincare disk.展开更多
The ophiolite suite in Shexian County, Anhui Province extends more than 40 km in NE orientation. It is called Fuchuan ophiolite because its outcrop is the most complete in Fuchuan. This ophiolite which upthrusts over ...The ophiolite suite in Shexian County, Anhui Province extends more than 40 km in NE orientation. It is called Fuchuan ophiolite because its outcrop is the most complete in Fuchuan. This ophiolite which upthrusts over the Precambrian Shexian granodiorite body is composed of dunite, harzburgite, cumulate pyroxenite, spilite, keratophyre and tuffaceous phyllite (Fig. 1).展开更多
In this paper, we present direct mass measurements of neutron-rich S6Kr projectile fragments conducted at the HIRFL-CSR facility in Lanzhou by employing the Isochronous Mass Spectrometry (IMS) method. The new mass e...In this paper, we present direct mass measurements of neutron-rich S6Kr projectile fragments conducted at the HIRFL-CSR facility in Lanzhou by employing the Isochronous Mass Spectrometry (IMS) method. The new mass excesses of ^52-54Sc nuclides are determined to be -40492(82), -38928(114), -34654(540) keV, which show a significant increase of binding energy compared to the reported ones in the Atomic Mass Evaluation 2012 (AME12). In particular, ^53Sc and ^54sc are more bound by 0.8 MeV and 1.0 MeV, respectively. The behavior of the two neutron separation energy with neutron numbers indicates a strong sub-shell closure at neutron number N=32 in Sc isotopes.展开更多
The 14 MeV, 400 μA compact cyclotron is under construction at China Institute of Atomic Energy (CIAE). The design of main magnet and the result of beam dynamics in the cyclotron will be described in this paper, inclu...The 14 MeV, 400 μA compact cyclotron is under construction at China Institute of Atomic Energy (CIAE). The design of main magnet and the result of beam dynamics in the cyclotron will be described in this paper, including the choice of main parameters of magnet, the method of shimming isochronous field in the compact cyclotron and optimization of the magnetic field in central region. The beam will be accelerated to 14.6 MeV by optimizing the magnet structure.展开更多
A pilot experiment of mass measurement was performed at CSRe with the method of isochronous mass spectrometry. The secondary fragments produced via RIBLL2 with the primary beam of 400 MeV/u ^36Ar delivered by CSRm wer...A pilot experiment of mass measurement was performed at CSRe with the method of isochronous mass spectrometry. The secondary fragments produced via RIBLL2 with the primary beam of 400 MeV/u ^36Ar delivered by CSRm were injected into CSRe. The revolution periods of the stored ions,which depend on the mass-to-charge ratios of the stored ions,were measured with a time-of-flight detector system. The results show that the mass resolution around 8×10^-6 for △m/m is achieved.展开更多
IEEE 1394b is a high-speed data bus that is widely used in local area networks and consumer electronics. To best utilize this data bus, we need to fully understand its per- formance. To evaluate its performance for bo...IEEE 1394b is a high-speed data bus that is widely used in local area networks and consumer electronics. To best utilize this data bus, we need to fully understand its per- formance. To evaluate its performance for both isochronous and asynchronous data transfers, we model the IEEE 1394b bus using Deterministic and Stochastic Pelri Nets (DSPNs), and conduct simulations using TimeNET 4.0. Using the DSPNs model, we simulate both the average waiting times of isochronous and asynchronous packets. From the simulation results, we determine the factors that influence performance, such as throughput, size of packets, arrival rate of packets, number of isochronous channels, and bus configuration.展开更多
In recent years, extensive short-lived nuclear mass measurements have been carried out at the Heavy- Ion Research Facility (HIRFL) in Lanzhou using Isochronous Mass Spectrometry (IMS). The obtained mass values hav...In recent years, extensive short-lived nuclear mass measurements have been carried out at the Heavy- Ion Research Facility (HIRFL) in Lanzhou using Isochronous Mass Spectrometry (IMS). The obtained mass values have been successfully applied to nuclear structure and astrophysics studies. In this contribution, we give a brief introduction to the nuclear mass measurements at HIRFL-CSR facility. Main technical developments are described and recent results are summarized. Furthermore, we envision the future perspective for the next-generation storage ring facility HIAF in Huizhou.展开更多
Recent commissioning of the Cooler Storage Ring at the Heavy Ion Research Facility in Lanzhou enabled us to conduct high-precision mass measurements at the Institute of Modern Physics in Lanzhou(IMP). In the past few ...Recent commissioning of the Cooler Storage Ring at the Heavy Ion Research Facility in Lanzhou enabled us to conduct high-precision mass measurements at the Institute of Modern Physics in Lanzhou(IMP). In the past few years, mass measurements were performed using the CSRe-based isochronous mass spectrometry employing the fragmentation of the energetic beams of58 Ni,78Kr,86 Kr,and112Sn projectiles. Masses of short-lived nuclides on both sides of the stability valley were addressed.Relative mass precision of down to 10-6~ 10-7is routinely achieved. The mass values were used as an input for dedicated nuclear structure and astrophysics studies, providing for instance new insights into the rp-process of nucleosynthesis in X-ray bursts. In this contribution, we briefly review the so far conducted experiments and the main achieved results, as well as outline the plans for future experiments.展开更多
The concept of isochronous mass spectrometry (IMS) applying two time-of-flight (TOF) detectors originated many years ago at GSI. However, the corresponding method for data analysis has never been discussed in deta...The concept of isochronous mass spectrometry (IMS) applying two time-of-flight (TOF) detectors originated many years ago at GSI. However, the corresponding method for data analysis has never been discussed in detail. Recently, two TOF detectors have been installed at CSRe and the new working mode of the ring is under test. In this paper, a data analysis method for this mode is introduced and tested with a series of simulations. The results show that the new IMS method can significantly improve mass resolving power via the additional velocity information of stored ions. This improvement is especially important for nuclides with Lorentz factor γ-value far away from the transition point yt of the storage ring CSRe.展开更多
The combination of in-flight fragment separator and the isochronous mass spectrometry(IMS)in storage rings have been proven to be a powerful tool for the precision mass measurements of shortlived exotic nuclei. In IMS...The combination of in-flight fragment separator and the isochronous mass spectrometry(IMS)in storage rings have been proven to be a powerful tool for the precision mass measurements of shortlived exotic nuclei. In IMS, the mass-over-charge ratio is only related to the revolution period of stored ions, and the relative mass resolution can reach up to the order of 10-6. However, the instability of the magnetic field of storage ring deteriorates the resolution of revolution period, making it very difficult to distinguish the ions with very close mass-over-charge ratio via their revolution periods. To improve the resolution of revolution periods, a new method of weighted shift correction(WSC) has been developed to accurately correct the influence of the magnetic field instabilities in the isochronous mass measurements of ^(58)Ni projectile fragments. By using the new method, the influence of unstable magnetic fields can be greatly reduced, and the mass resolution can be improved by a factor up to 1.7. Moreover, for the ions that still cannot be distinguished after correcting the magnetic field instabilities, we developed a new method of pulse height analysis for particle identification. By analyzing the mean pulse amplitude of each ion from the timing detector, the stored ions with close mass-over-charge ratios but different charge states such as ^(34)Ar and ^(51)Co can be identified, and thus the mass of ^(51)Co can be determined. The charge-resolved IMS may be helpful in the future experiments of isochronous mass measurement even for N = Z nuclei.展开更多
According to the newest matching mode between the two cyclotrons at HIRFL, the beam obit properties were researched, especially for the harm of existing ‘over-magnetic shim’ in SSC as well as the trajectory in the n...According to the newest matching mode between the two cyclotrons at HIRFL, the beam obit properties were researched, especially for the harm of existing ‘over-magnetic shim’ in SSC as well as the trajectory in the new mode. The results obtained are encouraging.展开更多
基金Supported by National Natural Science Foundation of China (10635080, 10221003)State Key Development Program of BasicsResearch of China (2007CB815000)Knowledge Innovation Project of Chinese Academy of Sciences (CXTD-J2005-1, KJCX2-SWN18)
文摘The Isochronous Mass Spectrometry is a high accurate mass spectrometer. A secondary electrons time detector has been developed and used for mass measurements. Secondary electrons from a thin carbon foil are accelerated by an electric field and deflected 180°by a magnetic field onto a micro-channel plate. The time detector has been tested with alpha particles and a time resolution of 197 ps (FWHM) was obtained in the laboratory. A mass resolution around 8×10^-6 for Am/m was achieved by using this time detector in a pilot mass measurement experiment.
基金supports provided by Natural Science Foundation of Shanghai(contract No.03ZR14022)the“Tenth Five”National Key Technological Research and Development Program(contract No.2001BA803B03)National Natural Science Foundation of China(contract No.50225517)are gratefully acknowledged.
文摘In this work, a parametric approach is presented and utilized to determine the creep properties of weldments; then the model of creep strain for cross weld specimen is given. On the basis of the experimental results, attempt has been made to establish equations of the isochronous stress-strain for weld joint that can predict the function of loading and service time in use of the creep data of base metal and weld metal.
基金supported by National Natural Science Foundation of China(No.12301197)Natural Science Foundation of Henan(No.232300420343)+2 种基金Science and Technology Research Project of Henan Province(No.232102210057)Scientific Research Foundation for Doctoral Scholars of Haust(No.13480077)Natural Science Foundation of Hunan(No.2021JJ30166)。
文摘This paper studies the global phase portraits of uniform isochronous centers system of degree six with polynomial commutator.Such systems have the form x=-y+xf(x,y),y=x+yf(x,y),where f(x,y)=a_(1)x+a_(2)xy+a_(3)xy^(2)+a_(4)xy^(3)+a_(5)xy^(4)=xσ(y),and any zero of 1+a_(1)y+a_(2)y^(2)+a_(3)y^(3)+a_(4)y^(4)+a_(5)y^(5),y=y is an invariant straight line.At last,all global phase portraits are drawn on the Poincare disk.
基金Project supported by the National Natural Science Foundation of China
文摘The ophiolite suite in Shexian County, Anhui Province extends more than 40 km in NE orientation. It is called Fuchuan ophiolite because its outcrop is the most complete in Fuchuan. This ophiolite which upthrusts over the Precambrian Shexian granodiorite body is composed of dunite, harzburgite, cumulate pyroxenite, spilite, keratophyre and tuffaceous phyllite (Fig. 1).
基金Supported by 973 Program of China(2013CB834401)the NSFC(U1232208,U1432125,11205205,11035007)the Helmholtz-CAS Joint Research Group(HCJRG-108)
文摘In this paper, we present direct mass measurements of neutron-rich S6Kr projectile fragments conducted at the HIRFL-CSR facility in Lanzhou by employing the Isochronous Mass Spectrometry (IMS) method. The new mass excesses of ^52-54Sc nuclides are determined to be -40492(82), -38928(114), -34654(540) keV, which show a significant increase of binding energy compared to the reported ones in the Atomic Mass Evaluation 2012 (AME12). In particular, ^53Sc and ^54sc are more bound by 0.8 MeV and 1.0 MeV, respectively. The behavior of the two neutron separation energy with neutron numbers indicates a strong sub-shell closure at neutron number N=32 in Sc isotopes.
基金supported by the National Natural Science Foundation of China (Grant No. 10805080)
文摘The 14 MeV, 400 μA compact cyclotron is under construction at China Institute of Atomic Energy (CIAE). The design of main magnet and the result of beam dynamics in the cyclotron will be described in this paper, including the choice of main parameters of magnet, the method of shimming isochronous field in the compact cyclotron and optimization of the magnetic field in central region. The beam will be accelerated to 14.6 MeV by optimizing the magnet structure.
基金Supported by National Natural Science Foundation of China (10635080, 10221003)State Key Development Program of Basics Research of China (2007CB815000)Knowledge Innovation Project of Chinese Academy of Sciences (CXTD-J2005-1, KJCX2-SW- N18)
文摘A pilot experiment of mass measurement was performed at CSRe with the method of isochronous mass spectrometry. The secondary fragments produced via RIBLL2 with the primary beam of 400 MeV/u ^36Ar delivered by CSRm were injected into CSRe. The revolution periods of the stored ions,which depend on the mass-to-charge ratios of the stored ions,were measured with a time-of-flight detector system. The results show that the mass resolution around 8×10^-6 for △m/m is achieved.
基金supported by the Aeronautics Science Foundation of China under Grant No. 2008ZC51
文摘IEEE 1394b is a high-speed data bus that is widely used in local area networks and consumer electronics. To best utilize this data bus, we need to fully understand its per- formance. To evaluate its performance for both isochronous and asynchronous data transfers, we model the IEEE 1394b bus using Deterministic and Stochastic Pelri Nets (DSPNs), and conduct simulations using TimeNET 4.0. Using the DSPNs model, we simulate both the average waiting times of isochronous and asynchronous packets. From the simulation results, we determine the factors that influence performance, such as throughput, size of packets, arrival rate of packets, number of isochronous channels, and bus configuration.
文摘In recent years, extensive short-lived nuclear mass measurements have been carried out at the Heavy- Ion Research Facility (HIRFL) in Lanzhou using Isochronous Mass Spectrometry (IMS). The obtained mass values have been successfully applied to nuclear structure and astrophysics studies. In this contribution, we give a brief introduction to the nuclear mass measurements at HIRFL-CSR facility. Main technical developments are described and recent results are summarized. Furthermore, we envision the future perspective for the next-generation storage ring facility HIAF in Huizhou.
基金National Basic Research Program of China(973 Program)(2013CB834401)National Natural Science Foundation of China(U1232208,U1432125,11205205,11035007)+3 种基金Chinese Academy of Sciences,and Helmholtz-CAS Joint Research Group(HCJRG-108)Ministry of Science and Technology of China(Talent Young Scientist Program)China Postdoctoral Science Foundation(2014M562481)Western Light Talent Training Program of Chinese Academy of Sciences
文摘Recent commissioning of the Cooler Storage Ring at the Heavy Ion Research Facility in Lanzhou enabled us to conduct high-precision mass measurements at the Institute of Modern Physics in Lanzhou(IMP). In the past few years, mass measurements were performed using the CSRe-based isochronous mass spectrometry employing the fragmentation of the energetic beams of58 Ni,78Kr,86 Kr,and112Sn projectiles. Masses of short-lived nuclides on both sides of the stability valley were addressed.Relative mass precision of down to 10-6~ 10-7is routinely achieved. The mass values were used as an input for dedicated nuclear structure and astrophysics studies, providing for instance new insights into the rp-process of nucleosynthesis in X-ray bursts. In this contribution, we briefly review the so far conducted experiments and the main achieved results, as well as outline the plans for future experiments.
基金Supported by the 973 Program of China(2013CB834401)National Nature Science Foundation of China(U1232208,U1432125,11205205,11035007)the Helmholtz-CAS Joint Research Group(Group No.HCJRG-108)
文摘The concept of isochronous mass spectrometry (IMS) applying two time-of-flight (TOF) detectors originated many years ago at GSI. However, the corresponding method for data analysis has never been discussed in detail. Recently, two TOF detectors have been installed at CSRe and the new working mode of the ring is under test. In this paper, a data analysis method for this mode is introduced and tested with a series of simulations. The results show that the new IMS method can significantly improve mass resolving power via the additional velocity information of stored ions. This improvement is especially important for nuclides with Lorentz factor γ-value far away from the transition point yt of the storage ring CSRe.
基金Natural Science Foundation of China(U1232208,U1432125,11205205,11035007,11235001,11320101004,11575007)National Basic Research Program of China(973 Program)(2013CB834401)
文摘The combination of in-flight fragment separator and the isochronous mass spectrometry(IMS)in storage rings have been proven to be a powerful tool for the precision mass measurements of shortlived exotic nuclei. In IMS, the mass-over-charge ratio is only related to the revolution period of stored ions, and the relative mass resolution can reach up to the order of 10-6. However, the instability of the magnetic field of storage ring deteriorates the resolution of revolution period, making it very difficult to distinguish the ions with very close mass-over-charge ratio via their revolution periods. To improve the resolution of revolution periods, a new method of weighted shift correction(WSC) has been developed to accurately correct the influence of the magnetic field instabilities in the isochronous mass measurements of ^(58)Ni projectile fragments. By using the new method, the influence of unstable magnetic fields can be greatly reduced, and the mass resolution can be improved by a factor up to 1.7. Moreover, for the ions that still cannot be distinguished after correcting the magnetic field instabilities, we developed a new method of pulse height analysis for particle identification. By analyzing the mean pulse amplitude of each ion from the timing detector, the stored ions with close mass-over-charge ratios but different charge states such as ^(34)Ar and ^(51)Co can be identified, and thus the mass of ^(51)Co can be determined. The charge-resolved IMS may be helpful in the future experiments of isochronous mass measurement even for N = Z nuclei.
文摘According to the newest matching mode between the two cyclotrons at HIRFL, the beam obit properties were researched, especially for the harm of existing ‘over-magnetic shim’ in SSC as well as the trajectory in the new mode. The results obtained are encouraging.