Chronic hepatitis B(CHB)infection is a major public health problem associated with significant morbidity and mortality worldwide.Twenty-three percent of patients with CHB progress naturally to liver cirrhosis,which wa...Chronic hepatitis B(CHB)infection is a major public health problem associated with significant morbidity and mortality worldwide.Twenty-three percent of patients with CHB progress naturally to liver cirrhosis,which was earlier thought to be irreversible.However,it is now known that cirrhosis can in fact be reversed by treatment with oral anti-nucleotide drugs.Thus,early and accurate diagnosis of cirrhosis is important to allow an appropriate treatment strategy to be chosen and to predict the prognosis of patients with CHB.Liver biopsy is the reference standard for assessment of liver fibrosis.However,the method is invasive,and is associated with pain and complications that can be fatal.In addition,intra-and inter-observer variability compromises the accuracy of liver biopsy data.Only small tissue samples are obtained and fibrosis is heterogeneous in such samples.This confounds the two types of observer variability mentioned above.Such limitations have encouraged development of non-invasive methods for assessment of fibrosis.These include measurements of serum biomarkers of fibrosis;and assessment of liver stiffness via transient elastography,acoustic radiation force impulse imaging,real-time elastography,or magnetic resonance elastography.Although significant advances have been made,most work to date has addressed the diagnostic utility of these techniques in the context of cirrhosis caused by chronic hepatitis C infection.In the present review,we examine the advantages afforded by use of non-invasive methods to diagnose cirrhosis in patients with CHB infections and the utility of such methods in clinical practice.展开更多
AIM: To investigate the combined diagnostic accuracy of acoustic radiation force impulse(ARFI), aspartate aminotransferase to platelet ratio index(APRI) and Forns index for a non-invasive assessment of liver fibrosis ...AIM: To investigate the combined diagnostic accuracy of acoustic radiation force impulse(ARFI), aspartate aminotransferase to platelet ratio index(APRI) and Forns index for a non-invasive assessment of liver fibrosis in patients with chronic hepatitis B(CHB). METHODS: In this prospective study, 206 patients had CHB with liver fibrosis stages F0-F4 classified by METAVIR and 40 were healthy volunteers were measured by ARFI, APRI and Forns index separately or combined as indicated. RESULTS: ARFI, APRI or Forns index demonstrated a significant correlation with the histological stage(all P < 0.001). According to the AUROC of ARFI and APRI for evaluating fibrotic stages more than F2, ARFI showed an enhanced diagnostic accuracy than APRI(P < 0.05). The combined measurement of ARFI and APRI exhibited better accuracy than ARFI alone when evaluating ≥ F2 fibrotic stage(Z = 2.77, P = 0.006). Combination of ARFI, APRI and Forns index did not obviously improve the diagnostic accuracy compared to the combination of ARFI and APRI(Z = 0.958, P = 0.338). CONCLUSION: ARFI + APRI showed enhanced diagnostic accuracy than ARFI or APRI alone for significant liver fibrosis and ARFI + APRI + Forns index shows the same effect with ARFI + APRI.展开更多
A three-dimensional numerical investigation of cross-flow past four circular cylinders in a diamond arrangement at Reynolds number of 200 is carried out.With the spacing ratios(L /D)ranging from 1.2 to 5.0,the flow ...A three-dimensional numerical investigation of cross-flow past four circular cylinders in a diamond arrangement at Reynolds number of 200 is carried out.With the spacing ratios(L /D)ranging from 1.2 to 5.0,the flow patterns can be classified into three basic regimes.The critical spacing ratio for the transition from narrow gap flow pattern to vortex impingement flow pattern around the cylinders is found to beL /D=3.0,while a single bluff-body flow pattern is observed atL /D=1.2.The relationship between the three-dimensional flow patterns and force characteristics around the four cylinders shows that the variation of forces and Strouhal numbers againstL /D are generally governed by these three kinds of flow patterns.It is concluded that the spacing ratio has important effects on the development of the free shear layers about the cylinders and hence has significant effects on the force and pressure characteristics of the four cylinders with different spacing ratios.展开更多
AIM: To explore the value of liver fibrosis assessment by acoustic radiation force impulse (ARFI) and the AST/PLT ratio index (APRI) in chronic hepatitis C patients.
基金Supported by A grant of the South Korea Healthcare technology R and D projectMinistry of Health and Welfare+1 种基金South KoreaNo.HI10C2020
文摘Chronic hepatitis B(CHB)infection is a major public health problem associated with significant morbidity and mortality worldwide.Twenty-three percent of patients with CHB progress naturally to liver cirrhosis,which was earlier thought to be irreversible.However,it is now known that cirrhosis can in fact be reversed by treatment with oral anti-nucleotide drugs.Thus,early and accurate diagnosis of cirrhosis is important to allow an appropriate treatment strategy to be chosen and to predict the prognosis of patients with CHB.Liver biopsy is the reference standard for assessment of liver fibrosis.However,the method is invasive,and is associated with pain and complications that can be fatal.In addition,intra-and inter-observer variability compromises the accuracy of liver biopsy data.Only small tissue samples are obtained and fibrosis is heterogeneous in such samples.This confounds the two types of observer variability mentioned above.Such limitations have encouraged development of non-invasive methods for assessment of fibrosis.These include measurements of serum biomarkers of fibrosis;and assessment of liver stiffness via transient elastography,acoustic radiation force impulse imaging,real-time elastography,or magnetic resonance elastography.Although significant advances have been made,most work to date has addressed the diagnostic utility of these techniques in the context of cirrhosis caused by chronic hepatitis C infection.In the present review,we examine the advantages afforded by use of non-invasive methods to diagnose cirrhosis in patients with CHB infections and the utility of such methods in clinical practice.
基金Shenzhen Municipal Science and Technology Innovation Fund,Nos.CXZZ20130322170220544 and JCYJ20140411112047885
文摘AIM: To investigate the combined diagnostic accuracy of acoustic radiation force impulse(ARFI), aspartate aminotransferase to platelet ratio index(APRI) and Forns index for a non-invasive assessment of liver fibrosis in patients with chronic hepatitis B(CHB). METHODS: In this prospective study, 206 patients had CHB with liver fibrosis stages F0-F4 classified by METAVIR and 40 were healthy volunteers were measured by ARFI, APRI and Forns index separately or combined as indicated. RESULTS: ARFI, APRI or Forns index demonstrated a significant correlation with the histological stage(all P < 0.001). According to the AUROC of ARFI and APRI for evaluating fibrotic stages more than F2, ARFI showed an enhanced diagnostic accuracy than APRI(P < 0.05). The combined measurement of ARFI and APRI exhibited better accuracy than ARFI alone when evaluating ≥ F2 fibrotic stage(Z = 2.77, P = 0.006). Combination of ARFI, APRI and Forns index did not obviously improve the diagnostic accuracy compared to the combination of ARFI and APRI(Z = 0.958, P = 0.338). CONCLUSION: ARFI + APRI showed enhanced diagnostic accuracy than ARFI or APRI alone for significant liver fibrosis and ARFI + APRI + Forns index shows the same effect with ARFI + APRI.
基金Project supported by Open Research Foundation of State Key Laboratory of Digital Manufacturing Equipment and Technology, Huazhong University of Science and Technology (Grant No. DMETKF2009016)the Fundamental Research Funds for the Central Universities (Grant No. 2010-Ia-030)
文摘A three-dimensional numerical investigation of cross-flow past four circular cylinders in a diamond arrangement at Reynolds number of 200 is carried out.With the spacing ratios(L /D)ranging from 1.2 to 5.0,the flow patterns can be classified into three basic regimes.The critical spacing ratio for the transition from narrow gap flow pattern to vortex impingement flow pattern around the cylinders is found to beL /D=3.0,while a single bluff-body flow pattern is observed atL /D=1.2.The relationship between the three-dimensional flow patterns and force characteristics around the four cylinders shows that the variation of forces and Strouhal numbers againstL /D are generally governed by these three kinds of flow patterns.It is concluded that the spacing ratio has important effects on the development of the free shear layers about the cylinders and hence has significant effects on the force and pressure characteristics of the four cylinders with different spacing ratios.
文摘AIM: To explore the value of liver fibrosis assessment by acoustic radiation force impulse (ARFI) and the AST/PLT ratio index (APRI) in chronic hepatitis C patients.