It was observed that hydrazine could enhance the chemiluminescence (CL) intensity of tris-(1,10 phenanthroline)ruthenium(Ⅱ) (Ru( phen)3^2+ )- Cerium( Ⅳ ) ice( Ⅳ )) system, based on which, a novel CL...It was observed that hydrazine could enhance the chemiluminescence (CL) intensity of tris-(1,10 phenanthroline)ruthenium(Ⅱ) (Ru( phen)3^2+ )- Cerium( Ⅳ ) ice( Ⅳ )) system, based on which, a novel CL system, Ru(phen)3^2+ Hydrazine-Ce(Ⅳ), was established. This CL system was investigated and employed to detect hydrazine. Under the optimum experimental conditions, the linear range and detection limit of the proposed method are 2.0× 10^-6-2.0×10^-3g·L^-1 and 1. 8×10^-6g·L^-1, respectively. For 1. 5 × 10^-5, 1.5×10^-4 and 1.2×10^-3 g·L^-1 hydrazine, the relative standard deviation (RSD) is 2.9%, 2.2% and 3. 1%, respectively (n= 11). The proposed method has been used to detect the content of hydrazine in the synthetic samples with satisfactory results.展开更多
The light emission produced by thiourea in oxidation process by permanganate in acidic solution in the presence of Ru(phen) 2+ 3 is used to determine 1.0×10 -8 \|1.0×10 -5 mol/L thiourea. The ...The light emission produced by thiourea in oxidation process by permanganate in acidic solution in the presence of Ru(phen) 2+ 3 is used to determine 1.0×10 -8 \|1.0×10 -5 mol/L thiourea. The limit of detection is 9.8×10 -9 mol/L and the relative standard deviation is 1.1% for a 1.0×10 -5 mol/L thiourea solution ( n =10). The method was applied satisfactorily to the determination of thiourea.展开更多
基金Supported by Alexander von Humboldt Founda-tion,the National Natural Science Foundation of China (20575046) National Key Basic Research and Development Program (973 Pro-gram,2002CB211800) .
文摘It was observed that hydrazine could enhance the chemiluminescence (CL) intensity of tris-(1,10 phenanthroline)ruthenium(Ⅱ) (Ru( phen)3^2+ )- Cerium( Ⅳ ) ice( Ⅳ )) system, based on which, a novel CL system, Ru(phen)3^2+ Hydrazine-Ce(Ⅳ), was established. This CL system was investigated and employed to detect hydrazine. Under the optimum experimental conditions, the linear range and detection limit of the proposed method are 2.0× 10^-6-2.0×10^-3g·L^-1 and 1. 8×10^-6g·L^-1, respectively. For 1. 5 × 10^-5, 1.5×10^-4 and 1.2×10^-3 g·L^-1 hydrazine, the relative standard deviation (RSD) is 2.9%, 2.2% and 3. 1%, respectively (n= 11). The proposed method has been used to detect the content of hydrazine in the synthetic samples with satisfactory results.
文摘The light emission produced by thiourea in oxidation process by permanganate in acidic solution in the presence of Ru(phen) 2+ 3 is used to determine 1.0×10 -8 \|1.0×10 -5 mol/L thiourea. The limit of detection is 9.8×10 -9 mol/L and the relative standard deviation is 1.1% for a 1.0×10 -5 mol/L thiourea solution ( n =10). The method was applied satisfactorily to the determination of thiourea.