A multi-spectrum bidirectional reflectance distribution function (BRDF) measurement system was developed with the adoption of single reference standard measurement method. An arm-adjustable corner device was designe...A multi-spectrum bidirectional reflectance distribution function (BRDF) measurement system was developed with the adoption of single reference standard measurement method. An arm-adjustable corner device was designed for the BRDF system. Changing the distance to the sample by moving the detector arm made the device applicable to different wavelengths. The system could be used for the spectrum range from visible light (0.6328μm) to mid-far infrared (10.6μm), the facular size between 0.8 3 cm. The rotating limit of detector arm was ±180°, the rotation range of sample holding table was 360°, and the angle resolution was 0.036°. A silicon carbide sample was measured using this system with reflectance zenith from -55° to +55°. According to the error analysis, the measurement uncertainty of this device was about 6.42%.展开更多
This paper presents a novel geometric parameters analysis to improve the measurement accuracy of stereo deflectometry.Stereo deflectometry can be used to obtain form information for freeform specular surfaces.A measur...This paper presents a novel geometric parameters analysis to improve the measurement accuracy of stereo deflectometry.Stereo deflectometry can be used to obtain form information for freeform specular surfaces.A measurement system based on stereo deflectometry typically consists of a fringe-displaying screen,a main camera,and a reference camera.The arrangement of the components of a stereo deflectometry system is important for achieving high-accuracy measurements.In this paper,four geometric parameters of a stereo deflectometry system are analyzed and evaluated:the distance between the main camera and the measured object surface,the angle between the main camera ray and the surface normal,the distance between the fringe-displaying screen and the object,and the angle between the main camera and the reference camera.The influence of the geometric parameters on the measurement accuracy is evaluated.Experiments are performed using simulated and experimental data.The experimental results confirm the impact of these parameters on the measurement accuracy.A measurement system based on the proposed analysis has been set up to measure a stock concave mirror.Through a comparison of the given surface parameters of the concave mirror,a global measurement accuracy of 154.2 nm was achieved.展开更多
In order to measure the rotation angle error of the worm and gear mechanisms in the atmospheric dispersion corrector( ADC),a novel measurement system based on the autocollimator is designed in this paper.Based on the ...In order to measure the rotation angle error of the worm and gear mechanisms in the atmospheric dispersion corrector( ADC),a novel measurement system based on the autocollimator is designed in this paper.Based on the position relations between the shaft and spot converged by rays of autocollimator,the rotation angle can be calculated quickly and conveniently using a brief algorithm. An optical wedge is introduced to the measurement system for suppressing the awful measuring error caused by the axial wobbly error. The measurement system can measure the shaft rotation angle at any rotation position,which is the novel usage of the two-dimensional autocollimator. Its optical layout is very simple. Only an optical wedge and two plane mirrors are needed besides the autocollimator. The measurement accuracy of the proposed method is less than±0.5 arcmin. In the measurement of two worms and gears mechanisms in ADC,the rotation angle error are±0.05° and ±0.07° respectively,which all satisfies the design demand( ±0.1°). The proposed measurement system can be also suits for some engineering fields.展开更多
基金This work was supported by the Key Subject Fund of 985II, the Postdoctoral Fund of China Postdoctoral Fund of Heilongjiang Province (No. 20060390783).
文摘A multi-spectrum bidirectional reflectance distribution function (BRDF) measurement system was developed with the adoption of single reference standard measurement method. An arm-adjustable corner device was designed for the BRDF system. Changing the distance to the sample by moving the detector arm made the device applicable to different wavelengths. The system could be used for the spectrum range from visible light (0.6328μm) to mid-far infrared (10.6μm), the facular size between 0.8 3 cm. The rotating limit of detector arm was ±180°, the rotation range of sample holding table was 360°, and the angle resolution was 0.036°. A silicon carbide sample was measured using this system with reflectance zenith from -55° to +55°. According to the error analysis, the measurement uncertainty of this device was about 6.42%.
文摘This paper presents a novel geometric parameters analysis to improve the measurement accuracy of stereo deflectometry.Stereo deflectometry can be used to obtain form information for freeform specular surfaces.A measurement system based on stereo deflectometry typically consists of a fringe-displaying screen,a main camera,and a reference camera.The arrangement of the components of a stereo deflectometry system is important for achieving high-accuracy measurements.In this paper,four geometric parameters of a stereo deflectometry system are analyzed and evaluated:the distance between the main camera and the measured object surface,the angle between the main camera ray and the surface normal,the distance between the fringe-displaying screen and the object,and the angle between the main camera and the reference camera.The influence of the geometric parameters on the measurement accuracy is evaluated.Experiments are performed using simulated and experimental data.The experimental results confirm the impact of these parameters on the measurement accuracy.A measurement system based on the proposed analysis has been set up to measure a stock concave mirror.Through a comparison of the given surface parameters of the concave mirror,a global measurement accuracy of 154.2 nm was achieved.
基金Sponsored by the National Natural Science Foundation of China(Grant Nos.11174274,11174279,61205021 and 11204299)
文摘In order to measure the rotation angle error of the worm and gear mechanisms in the atmospheric dispersion corrector( ADC),a novel measurement system based on the autocollimator is designed in this paper.Based on the position relations between the shaft and spot converged by rays of autocollimator,the rotation angle can be calculated quickly and conveniently using a brief algorithm. An optical wedge is introduced to the measurement system for suppressing the awful measuring error caused by the axial wobbly error. The measurement system can measure the shaft rotation angle at any rotation position,which is the novel usage of the two-dimensional autocollimator. Its optical layout is very simple. Only an optical wedge and two plane mirrors are needed besides the autocollimator. The measurement accuracy of the proposed method is less than±0.5 arcmin. In the measurement of two worms and gears mechanisms in ADC,the rotation angle error are±0.05° and ±0.07° respectively,which all satisfies the design demand( ±0.1°). The proposed measurement system can be also suits for some engineering fields.